Slit-light Laser Range Finding Using Perspective Warping Calibration (원근 와핑 보정을 이용한 선광원 레이저 거리 검출)

  • Ahn, Hyun-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.3
    • /
    • pp.232-237
    • /
    • 2010
  • In this paper, a slit light laser range finding method using perspective warping calibration is proposed. This approach has an advantage to acquire relatively high accuracy, although the optical system is nonlinear. In the calibration, we detect the calibration points which are marked on the calibration panel and acquire the center position of the slit light laser in the image, which are used for computing the real positions of the slit light by using perspective warping. A calibration file is obtained by integrating the calibration data with the transition of the panel. The range data is acquired by interpolating the center position of the slit light laser to the calibration coordinates. Experimental results show that the proposed method provides the accuracy of 0.08mm error in depth range of 130mm with the low cost optical system.

Development of a Ratio Calibration Bridge for Inductive Voltage Dividers (유도형 전압 분할기의 비 교정용 브리지 개발)

  • Kang Jeon Hong;Han Sang Ok;Kim Han Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.217-221
    • /
    • 2005
  • A inductive voltage divider(IVD) is widely used as a ratio arm of precise impedance measurement bridges at low frequencies of audio frequency range and a well fabricated IVD has ratio error of $10^{-7}$ order without any calibration. Recently, the order of $10^{-8}$ of the best measurement uncertainty is needed for calibration and maintenance of impedance standards as national standards. In order to achieve that uncertainty, the IVD which is used for a ratio arm of precise impedance measurement bridge should be calibrated within the uncertain of order of $10^{-8}$ For this purpose, a ratio calibration bridge for IVDs has been developed. The measurement uncertainties of both inphase and quadrature of the bridge are analyzed less then $3{\times}10^{-8}$ respectively at 1 kHz and 25 V.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Adaptive Calibration Method in Multiport Amplifier for K-Band Payload Applications

  • Moon, Seong-Mo;Shin, Dong-Hwan;Lee, Hong-Yul;Uhm, Man-Seok;Yom, In-Bok;Lee, Moon-Que
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.718-721
    • /
    • 2013
  • This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port-to-port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed $2{\times}2$ and $4{\times}4$ MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.

A Gradient Method Based Near-Field Range Estimation Technique Robust to Direction-of-Arrival Error (방위각 오차에 강인한 경사법 기반 근접장 표적 거리 추정 기법)

  • Kim, Joon-Doo;Cho, Chom-Gun;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.130-136
    • /
    • 2012
  • In this paper, we propose a near-field range estimation method for a uniform linear array that can calibrate bearing estimation error which give a bad influence on a range estimation process. When a range is fixed, the bearing error is calibrated to maximize the beamformer output by the proposed algorithm based on the gradient method. Simulation results show that the proposed algorithm can compensate the bearing error which is less than the mainlobe beamwidth so that reduce the range estimation error as similar as the case of no bearing error.

Calibration for the solar channel of COMS/MI using MODIS-derived BRDF parameters over desert targets

  • Sohn Byung-Ju;Chun Hyoung-wook
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.101-103
    • /
    • 2005
  • Vicarious calibration method using MODIS-derived surface reflectivity data as inputs to a radiative transfer model have been developed for the planned COMS solar channel. Pilot test was conduced over the Simpson Desert targets in Australia. Results suggested that calibration can be achieved within $5\%$ error range.

  • PDF

Evaluation Technique for Linearity of Ratio Error of Instrument Transformer Comparator Using Voltage Transformer with Wide Range of Error Ratios (넓은 범위의 비오차를 갖는 전압변성기를 이용한 계기용 변성기 비교 측정 장치의 비오차 직선성 평가기술)

  • Jung Jae Kap;Kwon Sung Won;Kim Han Jun;Park Young Tae;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.66-70
    • /
    • 2005
  • Linearity of ratio error of instrument transformer comparator has been tested using wide ratio error voltage transformer(VT) with the ratio errors in the range of -3 % to 3 %. The technique is the method for evaluation of the linearity for instrument transformer comparator by comparing both the theoretical and experimental values in wide ratio error VT. The developed method has been successfully applied for calibration and correction in instrument transformer comparator belonging to industry.

Application of Normality Test and Classification of Process Capability Index (공정능력지수의 유형화 및 정규성 검정의 응용)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.551-556
    • /
    • 2011
  • This research presents an implementation strategy of Process Capability Index (PCI) according to the types of process characteristics. The types of process feature are classified as four perspectives of variation range, time period, error position, and process stage. The paper examines short-term or long-term PCI, within or between variation, position of precision or accuracy, and inclusion of measurement or calibration stage. Moreover, the study proposes normality test of unilateral PCI.

  • PDF

Development of the Computer Vision based Continuous 3-D Feature Extraction System via Laser Structured Lighting (레이저 구조광을 이용한 3차원 컴퓨터 시각 형상정보 연속 측정 시스템 개발)

  • Im, D. H.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.159-166
    • /
    • 1999
  • A system to extract continuously the real 3-D geometric fearture information from 2-D image of an object, which is fed randomly via conveyor has been developed. Two sets of structured laser lightings were utilized. And the laser structured light projection image was acquired using the camera from the signal of the photo-sensor mounted on the conveyor. Camera coordinate calibration matrix was obtained, which transforms 2-D image coordinate information into 3-D world space coordinate using known 6 points. The maximum error after calibration showed 1.5 mm within the height range of 103mm. The correlation equation between the shift amount of the laser light and the height was generated. Height information estimated after correlation showed the maximum error of 0.4mm within the height range of 103mm. An interactive 3-D geometric feature extracting software was developed using Microsoft Visual C++ 4.0 under Windows system environment. Extracted 3-D geometric feature information was reconstructed into 3-D surface using MATLAB.

  • PDF

Development of Radiation Thermometer using InSb Photo-detector (인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구)

  • Hwang, Byeong-Oc;Lee, Won-Sik;Jhang, Kyung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF