• Title/Summary/Keyword: Range Block

Search Result 803, Processing Time 0.028 seconds

A Study on Implementing of AC-3 Decoding Algorithm Software (AC-3 Decoding Algorithm Software 구현에 관한 연구)

  • 이건욱;박인규
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1215-1218
    • /
    • 1998
  • 본 논문은 Digital Audio Compression(AC-3) Standard 인 A-52를 기반으로 하였으며 Borland C++3.1 Compiler를 사용하여 AC-3 Decoding Algorithm 구현하였다. Input Stream은 DVD VOB File에서 AC-3 Stream만을 분리하여 사용하며 최종 출력은 16 Bit PCM File이다. AC-3의 Frame구조는 Synchronization Information, Bit Stream Information, Audio Block, Auxiliary Data, Error Check로 구성된다. Aduio Block 은 모두 6개의 Block으로 나뉘어져 있다. BSI와 Side Information을 참조하여 Exponent를 추출하여 Exponent Strategy에 따라 Exponent를 복원한다. 복원된 Exponent 정보를 이용하여 Bit Allocation을 수행하여 각각의 Mantissa에 할당된 Bit수를 계산하고 Stream으로부터 Mantissa를 추출한다. Coupling Parameter를 참조하ㅕ Coupling Channel을 Original Channel로 복원시킨다. Stereo Mode에 대해서는 Rematrixing을 수행한다. Dynamic Range는 Mantissa와 Exponent의 Magnitude를 바꾸는 것으로 선택적으로 사용할 수 있다. Mantissa와 Exponent를 결합하여 Floating Point coefficient로 만든 후 Inverse Transform을 수행하면 PCM Data를 얻을 수 있다. PC에서 듣기 위해서는 Multi Channel을 Stereo나 Mono로 Downmix를 수행한다. 이렇게 만들어진 PCM data는 PCM Data를 재생하는 프로그램으로 재생할 수 있다.

  • PDF

A 3~5 GHz UWB Up-Mixer Block Using 0.18-μm CMOS Technology

  • Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.91-95
    • /
    • 2008
  • This paper presents a direct-conversion I/Q up-mixer block, which supports $3{\sim}5$ GHz ultra-wideband(UWB) applications. It consists of a VI converter, a double-balanced mixer, a RF amplifier, and a differential-to-single signal converter. To achieve wideband characteristics over $3{\sim}5$ GHz frequency range, the double-balanced mixer adopts a shunt-peaking load. The proposed RF amplifier can suppress unwanted common-mode input signals with high linearity. The proposed direct-conversion I/Q up-mixer block is implemented using $0.18-{\mu}m$ CMOS technology. The measured results for three channels show a power gain of $-2{\sim}-9$ dB with a gain flatness of 1dB, a maximum output power level of $-7{\sim}-14.5$ dBm, and a output return loss of more than - 8.8 dB. The current consumption of the fabricated chip is 25.2 mA from a 1.8 V power supply.

The Formation of Metal Nanoparticles in pH-responsive Block Copolymers and Hydrogels

  • Anastasiadis, S.H.;Vamvakaki, M.;Palioura, D.;Spyros, A.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.85-85
    • /
    • 2006
  • The micellization behavior and the metal-nanoparticle formation in PDEAEMA-b-PHEGMA double hydrophilic block copolymers are investigated. The hydrophobic PDEAEMA block is pH-sensitive: at low pH it can be protonated and it becomes hydrophilic, leading to molecular solubility, whereas at higher pH micelles are formed; the behavior is studied by DLS, NMR and AFM. In these micellar nanoreactors, metal nanorystals nucleate and grow upon reduction with sizes in the range of a few nm's as observed by TEM and XRD. Similarly, metal nanocrystals can be formed within pH-sensitive microgels (${\sim}250nm$ in diameter), synthesized by emulsion copolymerization of DEAEMA, which also exhibit reversible swelling properties in water by adjusting the pH.

  • PDF

A Continuous Versatile Reed-Solomon Decoder with Variable Code Rate and Block Length (가변 부호율과 블록 길이를 갖는 연속 가변형 리드솔로몬 복호기)

  • 공민한;송문규
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.549-552
    • /
    • 2003
  • In this paper, an efficient architecture of a versatile Reed-Solomon (RS) decoder is designed, where the message length k as well as the block length n can be variable. The decoder permits 3-step pipelined processing based on the modified Euclid's algorithm(MEA). A new architecture for the MEA is designed for variable values of error correcting capability t. To maintain the throughput rate with less circuitry, the MEA block uses both the recursive and the overclocking technique. The decoder can decode a codeword received not only in a burst mode, but also in a continuous mode. It can be used in a wide range of applications due to its versatility. A versatile RS decoder over GF(2$^{8}$ ) having the error-correcting capability of up to 10 has been designed in VHDL, and successfully synthesized in an FPGA chip.

  • PDF

Hexagonal to Cubic Phase Transition in the $D_2O$-Induced Reverse Micellar Solution of a PEO-b-PPO-b-PEO Block Copolymer

  • Kim, Do-Hyun;Ko, Yoon-Soo;Kwon, Yong-Ku
    • Macromolecular Research
    • /
    • v.16 no.1
    • /
    • pp.62-65
    • /
    • 2008
  • The morphology of the $D_2O$-induced reverse micellar structure of an amphiphilic block copolymer of poly( ethylene oxide )-b-poly(propylene oxide )-b-poly( ethylene oxide )($EO_{76}PO_{29}EO_{76}$) was investigated in hydrophobic media by small angle neutron scattering (SANS). Increasing $D_2O$ in the styrene/divinylbenzene solution of $EO_{76}PO_{29}EO_{76}$ led to a change in morphology of the reverse micelles from a short range ordered molecular aggregate to a hexagonally arranged micelle, and further to a spherical micelle.

An Experimental and Analytical Study on Axial Force-Moment Capacity of High-Strength Concrete Column under Eccentric Loads (편심을 받은 고강도 콘크리트 기둥의 출력-모멘트 강도에 관한 실험 및 해석적 연구)

  • 최창익;손혁수;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.468-474
    • /
    • 1997
  • High strength concrete is a more effective material for columns subject to axial force and moment than for other structural elements. The purpose of this study is to review strength calculation methods for high strength concrete columus by comparison of analytical values and experimental results. The variables of column test under eccentric loading were concrete compressive strength, longitudinal steel ratio, and eccentricity of load. The tied column sections of 120×120mm and 210×210mm were tested and the eccentricity of load varied in the range from 0.16 times to 0.54 times the column depth. The analytical results using the stress-strain relationship to 0.54 times the column depth. The analytical results using the stress-strain relationship as well as the ACI's rectangular block, Zia's modified block, and the trapezoidal block are compared with experimentally obtained data, and discussed in this paper.

  • PDF

Flow Control and Heat Transfer Enhancement from a Heated Block by an Inflow Pulsation (I) Flow Field Computation (입구 유동 가진에 의한 사각 발열체 주위의 유동제어 및 열전달촉진 (I) 유동장 수치해석)

  • 리광훈;김서영;성형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.592-598
    • /
    • 2002
  • The characteristics of a pulsating flow field from a heated block representing heat-dissipating electronic component in a channel have been numerically investigated. At the channel inlet a pulsating sinusoidal flow is imposed. The Reynolds number based on the channel height (H) is fixed at Re=500, and the forcing frequency is varied in the range of $0\leqSt\leq2$. Numerical results on the time-dependent flow field are obtained and averaged over a cycle of pulsation. The effect of the important governing parameters such as the Strouhal number is investigated in detail. The results indicate that the recirculating flow behind the block is substantially affected by the pulsation frequency. To characterize the periodic vortex shedding due to the inflow pulsation, numerical flow visualizations are carried out.

A Study on Mixed Convection in Parallel Flat Plate with Heated Rectangular Block Arrays (발열체가 있는 평행평판공간내의 대류열전달에 관한 수치해석)

  • Jung, B.Y.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.62-69
    • /
    • 1986
  • An analysis is made of the fully developed laminar flow and heat transfer in a parallel flat plate with heated rectangular block arrays to investigated the influence of bouyancy force. The shrouds is considered as adiabatic, while the heated block surface transmit a uniform rate of heat flux per unit axial length. The governing equations for velocity and temperature are solved by SIMPLE(Semi-Implicit Method Pressure Linked Equation) algorithm. Detailed velocity and temperature fields and overall heat transfer on wide range of Rayleigh number and various aspect ratios of heated rectangular blocks are computed. The result show that bouyancy leads to a significient enhancement in heat transfer along with a smaller increase in pressure drop, with the great enhancement found when the aspect ratio is 3.0.

  • PDF

Synthesis of Amphiphilic Poly(alkyl methacrylate-b-methacrylic acid) by Group Transfer Polymerization and Selective Hydrolysis

  • Soon Ki Kwon;Weon Jung Choi;Yun Hi Kim;Sam Kwon Choi
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.5
    • /
    • pp.479-482
    • /
    • 1992
  • Several poly(alkyl methacrylate-b-t-butyl methacrylate) diblock copolymers were synthesized by group transfer polymerization. The molecular weight of poly(t-butyl methacrylate) segments and the composition of the resulting block copolymers were controlled by the monomer feed ratios and mole ratios of monomer to initiator. The poly(t-butyl methacrylate) block was quantitatively hydrolyzed to poly(methacrylic acid) block by refluxing with a catalytic amount of p-toluenesulfonic acid in dioxane at $100^{\circ}C$ for 12 hrs. The thermogravimetric analysis of poly(alkyl methacrylate-b-t-butyl methacrylate) exhibited the lose of isobutylene and subsequent anhydride formation in the range of $205-300^{\circ}C$.

Heat Transfer from a Porous Heat Sink by Air Jet Impingement (충돌공기제트에서의 다공성 방열기의 열전달 특성)

  • 백진욱;김서영;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • Experiment were carried out to investigate the heat transfer characteristics of an aluminum foam block as a porous heat sink on a heat source by a vertical air jet impingement that can be applied for electronics cooling. The performance of the aluminum foam heat sink was evaluated by the convective heat transfer coefficient on the heat source. At a fixed porosity, pore density ($\beta$) of the foam and Reynolds number Re were varied in the range of $\beta$a=10, 20, 40 PPI(Pore Per Inch) and $850\leqRe\leq25000$. A nozzle diameter and the nozzle-to-plate spacing were also varied. It was found that the convective heat transfer was enhanced by the aluminum foam heat sink with lower pore density due to relatively intensified flow through the foam block. The aluminum foam block with much reduced weight shows slightly better performance with larger Nusselt number, compared with the convectional heat sink.

  • PDF