• Title/Summary/Keyword: Range Alignment

Search Result 255, Processing Time 0.027 seconds

The Predictable Factors of the Postoperative Kyphotic Change of Sagittal Alignment of the Cervical Spine after the Laminoplasty

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Kim, Dong Ha;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.577-583
    • /
    • 2017
  • Objective : Laminoplasty is an effective surgical method for treating cervical degenerative disease. However, postoperative complications such as kyphosis, restriction of neck motion, and instability are often reported. Despite sufficient preoperative lordosis, this procedure often aggravates the lordotic curve of the cervical spine and straightens cervical alignment. Hence, it is important to examine preoperative risk factors associated with postoperative kyphotic alignment changes. Our study aimed to investigate preoperative radiologic parameters associated with kyphotic deformity post laminoplasty. Methods : We retrospectively reviewed the medical records of 49 patients who underwent open door laminoplasty for cervical spondylotic myelopathy (CSM) or ossification of the posterior longitudinal ligament (OPLL) at Pusan National University Yangsan Hospital between January 2011 and December 2015. Inclusion criteria were as follows : 1) preoperative diagnosis of OPLL or CSM, 2) no previous history of cervical spinal surgery, cervical trauma, tumor, or infection, 3) minimum of one-year follow-up post laminoplasty with proper radiologic examinations performed in outpatient clinics, and 4) cases showing C7 and T1 vertebral body in the preoperative cervical sagittal plane. The radiologic parameters examined included C2-C7 Cobb angles, T1 slope, C2-C7 sagittal vertical axis (SVA), range of motion (ROM) from C2-C7, segmental instability, and T2 signal change observed on magnetic resonance imaging (MRI). Clinical factors examined included preoperative modified Japanese Orthopedic Association scores, disease classification, duration of symptoms, and the range of operation levels. Results : Mean preoperative sagittal alignment was $13.01^{\circ}$ lordotic; $6.94^{\circ}$ lordotic postoperatively. Percentage of postoperative kyphosis was 80%. Patients were subdivided into two groups according to postoperative Cobb angle change; a control group (n=22) and kyphotic group (n=27). The kyphotic group consisted of patients with more than $5^{\circ}$ kyphotic angle change postoperatively. There were no differences in age, sex, C2-C7 Cobb angle, T1 slope, C2-C7 SVA, ROM from C2-C7, segmental instability, or T2 signal change. Multiple regression analysis revealed T1 slope had a strong relationship with postoperative cervical kyphosis. Likewise, correlation analysis revealed there was a statistical significance between T1 slope and postoperative Cobb angle change (p=0.035), and that there was a statistically significant relationship between T1 slope and C2-C7 SVA (p=0.001). Patients with higher preoperative T1 slope demonstrated loss of lordotic curvature postoperatively. Conclusion : Laminoplasty has a high probability of aggravating sagittal balance of the cervical spine. T1 slope is a good predictor of postoperative kyphotic changes of the cervical spine. Similarly, T1 slope is strongly correlated with C2-C7 SVA.

A Comparison of Knee and Ankle Coronal Plane Alignment According to Quadriceps Exercise Method in Early Phase of Total Knee Arthroplasty: Lower Extremity Isometric Co-Contraction and Quadriceps Isolated Isometric Contraction (슬관절 전치환술 초기의 대퇴사두근 운동 방법에 따른 슬관절과 족관절의 관상면 정렬 비교: 하지 등척성 동시수축과 대퇴사두근 단독 등척성 수축)

  • Kim, Hyung-soo;Jeong, Young-hee
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Background: Total knee arthroplasty (TKA) recovers the alignment of the knee joint, but fails to automatically restore the alignment and function of the hip and ankle joints. It may affect the alignment and stability of the knee joint, therefore therapeutic intervention in hip and ankle joint is necessary for the rehabilitation process after TKA. Objects: The aim of this study was to comparison of the effects of the two exercise methods on the coronal plane alignment after TKA. This study conducted an experiment by dividing subjects into a lower extremity isometric co-contraction group (LEIC) and a quadriceps isolated isometric contraction (QIIC) group. Methods: A total of 37 subjects were randomly assigned to the LEIC ($n_1$=19) or the QIIC ($n_2$=18). Exercise was applied to five times per week for three weeks, starting on the eighth day after surgery. Range of motion exercises were performed as a common intervention and then each group performed quadriceps isometric contraction exercises with 10 sets of 5 repetitions. Radiological imaging was performed prior to surgery, one month and six months after surgery. In addition, the hip-knee-ankle angle (HKA) and tibiotalar angle (TTA) were measured. Results: The HKA was close to neutral in the LEIC rather than the QIIC (p<.05). The LEIC showed varus and the QIIC exhibited valgus TTA (p<.05). In a comparison of HKA and TTA over time, there was no significant change in either group (p>.05). According to the comparison of the TTA before surgery, the LEIC showed significant changes in the varus direction (p<.05), while there was no significant change in the QIIC (p>.05). Conclusion: The LEIC method triggered changes in the TTA and brought the HKA close to the neutral. Thus, LEIC is more effective than QIIC in creating stability in the coronal plane alignment of the knee and ankle joints after TKA.

A Robust Real-Time Mobile Robot Self-Localization with ICP Algorithm

  • Sa, In-Kyu;Baek, Seung-Min;Kuc, Tae-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2301-2306
    • /
    • 2005
  • Even if there are lots of researches on localization using 2D range finder in static environment, very few researches have been reported for robust real-time localization of mobile robot in uncertain and dynamic environment. In this paper, we present a new localization method based on ICP(Iterative Closest Point) algorithm for navigation of mobile robot under dynamic or uncertain environment. The ICP method is widely used for geometric alignment of three-dimensional models when an initial estimate of the relative pose is known. We use the method to align global map with 2D scanned data from range finder. The proposed algorithm accelerates the processing time by uniformly sampling the line fitted data from world map of mobile robot. A data filtering method is also used for threshold of occluded data from the range finder sensor. The effectiveness of the proposed method has been demonstrated through computer simulation and experiment in an office environment.

  • PDF

Compact Gearless Elevator System Using PMSM (영구자석형 동기 전동기를 이용한 Compact Gearless 엘리베이터 시스템)

  • 안준선;김일종;배승형;강석주;이제필
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.1-3
    • /
    • 1999
  • The implementation of the compact gearless elevator system with Permanent Magnet Synchronous Motor is presented. For the purpose of the voltage suppression in the motor input side, the LRC filter is used. The automatic encoder alignment algorithm with rotor pole position is developed, and it is available in the full range of the load. The implemented system makes 11% energy savings comparing the system with the induction motor.

  • PDF

Synthesis and Properties of New Aromatic Polyimides for IPS-mode

  • Kim, Y.B.;Park, J.C.;Park, D.J.;Son, K.C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.792-795
    • /
    • 2006
  • In-plane-switching (IPS)-mode LCD is one of the most useful technologies for a broad range of viewing angles. To apply for IPS-LCDs, we synthesized novel homogeneous alignment materials, changing dianhydrides (BTDA and BPDA) and bridged diamines (ODA and PACM). We measured their pre-tilt angles using the crystal rotation method with positive LC and their surface properties.

  • PDF

Development of Low Anchoring Strength Liquid Crystal Mixtures for Bistable Nematic Displays

  • Stoenescu, D.;Lamarque-Forget, S.;Joly, S.;Dubois, J.C.;Martinot-Lagarde, Ph.;Dozov, I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.97-100
    • /
    • 2005
  • The recent Bistable Nematic ($BiNem{(R)}$) LCD technology presents long term bistability, high level passive matrix multiplexing and high optical quality. The BiNem device, based on anchoring breaking, needs specific low anchoring strength materials - alignment layers and liquid crystal mixtures. We present here our approach to develop nematic mixtures with wide enough temperature range and low zenithal anchoring energy.

  • PDF

Daily check device manufacture and efficiency Evaluation for daily Q.A (일일 정도관리를 위한 Daily check device 의 제작 및 효율성 평가)

  • Kim Chan Yong;Je Yeong Wan;Lee Je Hui;Park Heung Deuk
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.19-22
    • /
    • 2005
  • Introduction: Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Methods and Materials: Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment, field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Result: We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}\;2\%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}\;1mm$. Conclusion: We can enforce output measurement and appliances check conveniently and time was reduced and was able to raise efficiency of business. We were able to bring n cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

An AFM-based Edge Profile Measuring Instrument for Diamond Cutting Tools

  • Asai, Takemi;Motoki, Takenori;Gao, Wei;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.54-58
    • /
    • 2007
  • This paper describes an atomic force microscope (AFM)-based instrument for measuring the nanoscale cutting edge profiles of diamond cutting tools. The instrument consists of a combined AFM unit and an optical sensor to align the AFM tip with the top of the diamond cutting tool edge over a submicron range. In the optical sensor, a aser beam is emitted from a laser diode along the Y-axis and focused to a small beam spot with a diameter of approximately $10{\mu}m$ at the beam waist, which is then received by a photodiode. The top of the tool edge is first brought into the center of the beam waist by adjusting it in the X-Z-plane while monitoring the variation in the photodiode output. The cutting tool is then withdrawn and its top edge position at the beam center is recorded. The AFM tip can also be positioned at the beam center in a similar manner to align it with the top of the cutting edge. To reduce electronic noise interference on the photodiode output and thereby enhance the alignment accuracy, a technique is applied that can modulate the photodiode output to an AC signal by driving the laser diode with a sinusoidal current. Alignment experiments and edge profile measurements of a diamond cutting tool were carried out to verify the performance of the proposed system.

Effect of Active Intervention after Kaltenborn's Cervical Joint Mobilization on The Cervical Spine Alignment and Muscle Activity in Patients with Forward Head Posture (칼텐본 경추 관절가동술 후 적용된 능동적 중재가 두부 전방자세 환자의 경추 정렬과 근활성도에 미치는 영향)

  • Lee, Kang-Jin;Roh, Jung-Suk;Choi, Houng-Sik;Cynn, Heon-Seock;Choi, Kyu-Hwan;Kim, Tack-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.17-27
    • /
    • 2015
  • PURPOSE: The purpose of this study was to compare the effects of three interventions (intervention by passive range of motion exercise plus manual cervical traction, Mulligan's joint mobilization, and strengthening exercises) after Kaltenborn's joint mobilization on the cervical spine alignment, and muscle activity in patients with a forward head posture. METHODS: The subjects were 39 students from H University in Chungnam and C University in Jeonbuk. The subjects in each group attended training sessions three times a week for four weeks. We used one-way ANOVA and Scheffe's post hoc test to compare values between groups, and used paired t-test to compare the values of the dependent variables within groups. RESULTS: The results showed that the active intervention group experienced a significant increase compared to the passive intervention group in terms of the craniovertebral angle, cervical lordosis angle, and had significant decreases compared to the passive intervention group in terms of the upper trapezius muscle activity. The active intervention group also had significant increases in craniovertebral angle and decreased anterior scalene muscle activity than the active-assistive intervention group. The active-assistive intervention group had significant decreases compared to the active intervention group in terms of the serratus anterior, levator scapulae, and splenius capitis muscle activity. CONCLUSION: It appears that the subjects with a forward head posture had significant improvements in the cervical lordosis angle, cranial rotation angle, craniovertebral angle, and muscle activity after intervention by Mulligan's joint mobilization (active-assistive intervention component) and strengthening exercises (active intervention component) after applying Kaltenborn's joint mobilization.

Preoperative Radiological Parameters to Predict Clinical and Radiological Outcomes after Laminoplasty

  • Lee, Su Hun;Son, Dong Wuk;Shin, Jun Jae;Ha, Yoon;Song, Geun Sung;Lee, Jun Seok;Lee, Sang Weon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.677-692
    • /
    • 2021
  • Many studies have focused on pre-operative sagittal alignment parameters which could predict poor clinical or radiological outcomes after laminoplasty. However, the influx of too many new factors causes confusion. This study reviewed sagittal alignment parameters, predictive of clinical or radiological outcomes, in the literature. Preoperative kyphotic alignment was initially proposed as a predictor of clinical outcomes. The clinical significance of the K-line and K-line variants also has been studied. Sagittal vertical axis, T1 slope (T1s), T1s-cervical lordosis (CL), anterolisthesis, local kyphosis, the longitudinal distance index, and range of motion were proposed to have relationships with clinical outcomes. The relationship between loss of cervical lordosis (LCL) and T1s has been widely studied, but controversy remains. Extension function, the ratio of CL to T1s (CL/T1s), and Sharma classification were recently proposed as LCL predictors. In predicting postoperative kyphosis, T1s cannot predict postoperative kyphosis, but a low CL/T1s ratio was associated with postoperative kyphosis.