• Title/Summary/Keyword: Range Alignment

Search Result 255, Processing Time 0.024 seconds

Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom (AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정)

  • Jong-Eon, Kim;Sang-Hun, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.771-778
    • /
    • 2022
  • The purpose of this study is to present a method of measuring noise by the percentage of effective line attenuation coefficient of water that can be used for quality control of CT image noise using AAPM CT performance phantom in clinical practice. In the CT images obtained by scanning the AAPM CT performance phantom with a 120 kVp CT X-ray beam, the mean CT number was measured for each pin and water in the CT number linearity insert part. The effective energy was determined as the photon energy with the largest correlation coefficient from the correlation coefficients of the linear regression analysis of the measured mean CT number for each pin and water and the linear attenuation coefficient for each photon energy. And for water and acrylic, the contrast scale was calculated as 0.000188 cm-1 · HU-1 from the measured mean CT number and effective line attenuation coefficient. Using the calculated contrast scale, the effective line attenuation coefficient of water, and the standard deviation measured in the water of the alignment pin part of the AAPM CT performance phantom, The noise measurement value by the percentage of effective line attenuation coefficient of water obtained 0.31 ~ 0.52% in the range of 100 ~ 300 mAs.

Mid-Term Results of Fixed Bearing Unicompartmental Knee Arthroplasty: Minimum 5-Year Follow-Up (고정형 슬관절 단일 구획 치환술의 중기 추시 결과: 최소 5년 추시)

  • Oh, Jeong Han;Joo, Il-Han;Kong, Dong-Yi;Choi, Choong-Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.498-504
    • /
    • 2018
  • Purpose: To evaluate the clinical and radiological outcomes, and the complications of unicompartmental knee arthroplasty (UKA) using a fixed bearing prosthesis after 5-year follow-up. Materials and Methods: Twenty-six knees (25 patients) that underwent fixed bearing UKA between May 2003 and August 2011 were included. The subjects were 3 males (3 knees) and 22 females (23 knees), and the average age was 63.5 years. The preoperative diagnosis was osteoarthritis (23 knees) and osteonecrosis (3 knees). The mean follow-up duration was 67 months (from 60 to 149 months). The clinical evaluation included pre- and postoperative American knee society knee and function score, and range of motion. The radiology evaluation included standing antero-posterior, lateral view, and fluoroscopic film to analyze the postoperative alignment and osteolysis. Results: The mean American Knee Society knee score and function score were improved from 42.0 and 57.5 to 87.9 and 85.0, respectively (p<0.001). The mean preoperative and postoperative range of motion was $132.9^{\circ}$ and $132.5^{\circ}$, respectively. The mean femorotibial angle were varus $0.5^{\circ}$ preoperatively and valgus $2.2^{\circ}$ postoperatively. A radiolucent line was observed in 2 knees; one knee had a stable implant, while in the other knee, patellofemoral arthritis was identified during UKA. Diffuse pain of the knee joint with tenderness of the medial joint line was identified at the follow-up, so conversion to total knee arthroplasty was recommended. No other complications, such as osteolysis, infections, postoperative stiffness, and dislocation, were encountered. Conclusion: The midterm results of fixed bearing UKA were clinically and radiologically satisfactory.

Mean Field Analysis of Exchange Coupling in Amorphous RE$Fe_2$-B (RE=Dy, Sm) Alloy Ribbons (비정질 RE$Fe_2$-B (RE=Dy, Sm) 합금 리본에서 평균장 이론에 의한 교환상호작용 계산)

  • Lee, J. M.;J. K. Jung;S.H. Lim
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.85-96
    • /
    • 2001
  • Experimental magnetization-temperature curves for melt-spun ribbons of amorphous alloys (Dy$\_$0.33/Fe$\_$0.67/)$\_$1-x/B$\_$x/(x=0 ,0.05, 0.1, and 0.15) and (Sm$\_$0.33/Fe$\_$0.67/)$\_$1-x/B$\_$x/(x=0, 0.01, 0.02, and 0.03) (in atomic fraction) are fitted with theoretical equations based on the mean field theory in order to calculate exchange couplings between constituent elements as a function of the B content. In the case of the DyFe$_2$-B system, the sign of the exchange coupling between Dy and Fe is negative, indicating that the magnetization direction of Dy is antiparallel to that of Fe. The sign of the other two couplings are positive indicating a parallel alignment. The exchange coupling between Fe ions are greatest, while that between Dy ions is negligible. In the case of the SmFe$_2$B alloys, the sign of all the couplings are positive, indicating ferromagnetic coupling between the spins. The exchange couplings between Fe ions, and Fe and Sm are comparable to each other, but they are much greater than that between Sm ions. The high exchange coupling between Fe and Sm, which is considered to occur indirectly, is rather unexpected, but it is considered to be unique characteristics of amorphous Sm-Fe alloys. In both alloy systems, the exchange coupling between Fe ions increases with increasing B content. and this may be explained by the increase of the Fe-Fe separation with increasing B content. The exchange coupling between Fe and RE also increases with increasing B content. As the B content increases, the magnetization decreases over the whole temperature range, and the Curie temperature also decreases.

  • PDF

Effects of the PNF Leg Pattern according to Chain Exercise Postures and Resistance Intensity on the Contralateral Leg's Muscle Activity (사슬운동자세와 저항강도에 따른 PNF 다리패턴이 반대측 다리의 근활성도에 미치는 영향)

  • Seok, Him;Yoon, Sung-Young;Heo, Jae-Seok;Lee, Sang-Yeol
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.423-433
    • /
    • 2021
  • Purpose: Proprioceptive neuromuscular facilitation (PNF) is a method for promoting functional movements by facilitating neuromuscular responses through the stimulation of proprioceptors in the body using spiral and diagonal patterns. Irradiation, a basic principle of PNF, is a phenomenon in which the muscle activity of a body part caused by resistance is increased or spread into muscles in other parts via their connected muscles. Resistance training can be divided by body alignment into closed and open chain exercises. Methods: In this study, 19 healthy men in their 20s and 30s were selected as subjects. They performed PNF hip flexion, abduction, and internal rotation motions on their dominant side in an open chain exercise posture in which the nondominant sole was away from the wall, and in a closed chain exercise posture in which the sole was fixed to the wall. The nondominant leg's muscle activity was measured while resistance was maintained with applied pressure at 0%, 25%, 50%, 75%, and 100% of the maximum muscle strength in the last range of motions. A two-way analysis of variance (ANOVA) was conducted for a comparative analysis of the contralateral leg's muscle activity according to the chain exercise postures and the intensity of resistance intensity during PNF hip flexion, abduction, and internal rotation. In addition, an independent sample T-test was conducted for a comparative analysis of each chain exercise posture according to the intensity of resistance. A one-way ANOVA and a Scheffe post-hoc test were also performed to analyze the contralateral leg's muscle activity according to the intensity of resistance in the closed and open chain exercise postures. Results: Results of the two-way ANOVA found that the gluteus medius and the biceps femoris had statistically significant differences in both the chain exercise postures and resistance intensity (p<0.05), and that the vastus medialis and the gastrocnemius did not exhibit statistically significant differences in the chain exercise postures (p>0.05) but showed statistically significant differences in resistance intensity (p<0.05). As a result of the independent sample T-test, the application of the PNF hip flexion-abduction-internal rotation pattern led to a statistically significant difference in the contralateral gluteus medius during the closed chain exercise posture (p<0.05). According to the results of the one-way ANOVA and the Scheffe post-analysis, statistically significant differences were observed in the gluteus medius at 50%, biceps femoris at 75%, vastus medialis at 100%, and gastrocnemius at 100% during the closed chain exercise posture based on a resistance intensity of 0% (p<0.05). In the open chain exercise posture, statistically significant differences were found in the gluteus medius at 50%, biceps femoris at 50%, and vastus medialis at 75% based on the resistance intensity of 0% (p<0.05). In the same posture, there was no significant difference in the gastrocnemius's resistance intensity (p>0.05). Conclusion: When the PNF leg pattern is applied, each muscle requires effective chain exercise postures and resistance intensity to generate the contralateral leg muscle's irradiation.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.