• Title/Summary/Keyword: Range Alignment

Search Result 255, Processing Time 0.025 seconds

Transferring Calibrations Between on Farm Whole Grain NIR Analysers

  • Clancy, Phillip J.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1210-1210
    • /
    • 2001
  • On farm analysis of protein, moisture and oil in cereals and oil seeds is quickly being adopted by Australian farmers. The benefits of being able to measure protein and oil in grains and oil seeds are several : $\square$ Optimize crop payments $\square$ Monitor effects of fertilization $\square$ Blend on farm to meet market requirements $\square$ Off farm marketing - sell crop with load by load analysis However farmers are not NIR spectroscopists and the process of calibrating instruments has to the duty of the supplier. With the potential number of On Farm analyser being in the thousands, then the task of calibrating each instrument would be impossible, let alone the problems encountered with updating calibrations from season to season. As such, NIR technology Australia has developed a mechanism for \ulcorner\ulcorner\ulcorner their range of Cropscan 2000G NIR analysers so that a single calibration can be transferred from the master instrument to every slave instrument. Whole grain analysis has been developed over the last 10 years using Near Infrared Transmission through a sample of grain with a pathlength varying from 5-30mm. A continuous spectrum from 800-1100nm is the optimal wavelength coverage fro these applications and a grating based spectrophotometer has proven to provide the best means of producing this spectrum. The most important aspect of standardizing NIB instruments is to duplicate the spectral information. The task is to align spectrum from the slave instruments to the master instrument in terms of wavelength positioning and then to adjust the spectral response at each wavelength in order that the slave instruments mimic the master instrument. The Cropscan 2000G and 2000B Whole Grain Analyser use flat field spectrographs to produce a spectrum from 720-1100nm and a silicon photodiode array detector to collect the spectrum at approximately 10nm intervals. The concave holographic gratings used in the flat field spectrographs are produced by a process of photo lithography. As such each grating is an exact replica of the original. To align wavelengths in these instruments, NIR wheat sample scanned on the master and the slave instruments provides three check points in the spectrum to make a more exact alignment. Once the wavelengths are matched then many samples of wheat, approximately 10, exhibiting absorbances from 2 to 4.5 Abu, are scanned on the master and then on each slave. Using a simple linear regression technique, a slope and bias adjustment is made for each pixel of the detector. This process corrects the spectral response at each wavelength so that the slave instruments produce the same spectra as the master instrument. It is important to use as broad a range of absorbances in the samples so that a good slope and bias estimate can be calculated. These Slope and Bias (S'||'&'||'B) factors are then downloaded into the slave instruments. Calibrations developed on the master instrument can then be downloaded onto the slave instruments and perform similarly to the master instrument. The data shown in this paper illustrates the process of calculating these S'||'&'||'B factors and the transfer of calibrations for wheat, barley and sorghum between several instruments.

  • PDF

Reconstruction of Anterior Cruciate Ligament in Adolescent (청소년기에 시행한 전방십자인대 재건술)

  • Song Eun Kyoo;Shim Sang Don;Kim Hyung Jong;Kim Hyung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2002
  • Purpose: To evaluate the clinical results of anterior cruciate ligament (ACL) reconstruction and to know the results of physeal injury by transphyseal tunnel in adolescents who had remaining growth potential. Materials and Methods : This study involved 12 patients under 19 years old out of 445 patients, who underwent ACL reconstruction between 1993 and 2001. The mean age at the time of operation was 15.9 $(13.1\~16.9)$ years and fellow-up period was 45.1 $(24\~120.6)$ months in avrarge. Autologous quadrupled hamstring tendon was used as graft in 11 cases and bone-patellar tendon-bone in 1 case. Clinical results were evaluated by Lysholm Knee Scoring Scale, range of motion and return to preinjury sports activities. Radiologic results were evaluated by $Telos^{\circledR}$ device. Bone maturity were analyzed by chronological age, standing height and the width of growth plate in AP and lateral view of knee joint at preoperatively. The growth disturbances were evaluated by measuring femorotibial angle, anatomical and mechanical lateral distal femoral angle, mechanical medial proximal tibial angle and leg length and by comparing those of uninjured site in last follow-up teleoroentgenogram. Results : The mean Lysholm Knee score was 51 $(25\~63)$points preoperatively and 98 $(94\~100)$ points at last follow up. The mean anterior displacement of the tibia by using $Telos^{\circledR}$ device was improved from 13.5 $(6\~27)$ mm to 2.9 $(1\~4)$ mm and there were no significant instabilities of the knee in all cases. There were no leg length discrepancies over 1 cm and no statistically significant abnormal alignment of the knee joint in all cases. Conclusion: ACL reconstruction using transphyseal tunnel for restoring stability and knee function is assumed as a good mettled of treatment without significant leg length discrepancy and abnormal alignment of the knee joint.

  • PDF

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Treatment of Distal Tibial Spiral Fractures Combined with Posterior Malleolar Fractures (후과 골절이 동반된 경골 원위부 나선상 골절의 치료)

  • Kim, Young Sung;Lee, Ho Min;Kim, Jong Pil;Chung, Phil Hyun;Park, Soon Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.317-325
    • /
    • 2021
  • Purpose: This study compared the functional and radiologic outcomes of intramedullary nailing (IMN) and minimally invasive plate osteosynthesis (MIPO) for tibia fractures in distal tibial spiral fractures combined with posterior malleolar fractures, as well as the functional and radiologic outcomes with and without fixation for posterior malleolar fractures. Materials and Methods: From January 2010 to December 2018 the radiological and clinical outcomes of 30 skeletally mature patients with tibial spiral fractures (AO Foundation/Orthopaedic Trauma Association classification 42-A1, B1, C1) combined with posterior malleolar fractures were analyzed. Sixteen patients were treated with IMN, and 14 patients were treated with MIPO. Depending on the surgical methods, the radiologic and clinical outcomes were compared by evaluating the bone union time, postoperative alignment, postoperative displacement of the posterior malleolar fragment, and American Orthopaedic Foot and Ankle Society (AOFAS) score. Moreover, the functional and clinical outcomes with and without fixation for posterior malleolar fractures were compared. Results: The mean bone union time was 21.8 weeks in the IMN group and 23.1 weeks in the MIPO group (p=0.500). At the final follow up, the mean alignment was coronal angulation of 1.8°, sagittal angulation of 1.6° in the IMN group and coronal angulation of 1.2° and sagittal angulation of 1.7° in the MIPO group (conoral angulation: p=0.131, sagittal angulation: p=0.850). The postoperative and final radiologic evaluation showed no displacement of the posterior malleolar fragment and excellent joint congruity in all cases. At the final follow-up, the mean AOFAS score was 88.0 on average in the IMN group and 87.6 on average in the MIPO group (p=0.905). The ankle range of motion and AOFAS score were similar in the fixation group and no fixation group for posterior malleolar fractures. Conclusion: Both IMN and MIPO for tibial spiral fractures combined with posterior malleolar fractures result in satisfactory radiological and clinical outcomes.

Cloning and Expression of the Cathepsin F-like Cysteine Protease Gene in Escherichia coli and Its Characterization

  • Joo, Han-Seung;Koo, Kwang-Bon;Park, Kyun-In;Bae, Song-Hwan;Yun, Jong-Won;Chang, Chung-Soon;Choi, Jang-Won
    • Journal of Microbiology
    • /
    • v.45 no.2
    • /
    • pp.158-167
    • /
    • 2007
  • In this study, we have cloned a novel cDNA encoding for a papain-family cysteine protease from the Uni-ZAP XR cDNA library of the polychaete, Periserrula leucophryna. This gene was expressed in Escherichia coli using the T7 promoter system, and the protease was characterized after partial purification. First, the partial DNA fragment (498 bp) was amplified from the total RNA via RT-PCR using degenerated primers derived from the conserved region of cysteine protease. The full-length cDNA of cysteine protease (PLCP) was prepared via the screening of the Uni-ZAP XR cDNA library using the $^{32}P-labeled$ partial DNA fragment. As a result, the PLCP gene was determined to consist of a 2591 bp nucleotide sequence (CDS: 173-1024 bp) which encodes for a 283-amino acid polypeptide, which is itself composed of an 59-residue signal sequence, a 6-residue propeptide, a 218-residue mature protein, and a long 3'-noncoding region encompassing 1564 bp. The predicted molecular weights of the preproprotein and the mature protein were calculated as 31.8 kDa and 25 kDa, respectively. The results of sequence analysis and alignment revealed a significant degree of sequence similarity with other eukaryotic cysteine proteases, including the conserved catalytic triad of the $Cys^{90},\;His^{226},\;and\;Asn^{250}$ residues which characterize the C1 family of papain-like cysteine protease. The nucleotide and amino acid sequences of the novel gene were deposited into the GenBank database under the accession numbers, AY390282 and AAR27011, respectively. The results of Northern blot analysis revealed the 2.5 kb size of the transcript and ubiquitous expression throughout the entirety of the body, head, gut, and skin, which suggested that the PLCP may be grouped within the cathepsin F-like proteases. The region encoding for the mature form of the protease was then subcloned into the pT7-7 expression vector following PCR amplification using the designed primers, including the initiation and termination codons. The recombinant cysteine proteases were generated in a range of 6.3 % to 12.5 % of the total cell proteins in the E. coli BL21(DE3) strain for 8 transformants. The results of SDS-PAGE and Western blot analysis indicated that a cysteine protease of approximately 25 kDa (mature form) was generated. The optimal pH and temperature of the enzyme were determined to be approximately 9.5 and $35^{\circ}C$, respectively, thereby indicating that the cysteine protease is a member of the alkaline protease group. The evaluation of substrate specificity indicated that the purified protease was more active towards Arg-X or Lys-X and did not efficiently cleave the substrates with non-polar amino acids at the P1 site. The PLCP evidenced fibrinolytic activity on the plasminogen-free fibrin plate test.

Design and Performance Analysis of an Off-Axis Three-Mirror Telescope for Remote Sensing of Coastal Water (연안 원격탐사를 위한 비축 삼반사경 설계와 성능 분석)

  • Oh, Eunsong;Kang, Hyukmo;Hyun, Sangwon;Kim, Geon-Hee;Park, YoungJe;Choi, Jong-Kuk;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • We report the design and performance analysis of an off-axis three-mirror telescope as the fore optics for a new hyperspectral sensor aboard a small unmanned aerial vehicle (UAV), for low-altitude coastal remote sensing. The sensor needs to have at least 4 cm of spatial resolution at an operating altitude of 500 m, $4^{\circ}$ field of view (FOV), and a signal to noise ratio (SNR) of 100 at 660 nm. For these performance requirements, the sensor's optical design has an entrance pupil diameter of 70 mm and an F-ratio of 5.0. The fore optics is a three-mirror system, including aspheric primary and secondary mirrors. The optical performance is expected to reach $1/15{\lambda}$ in RMS wavefront error and 0.75 in MTF value at 660 nm. Considering the manufacturing and assembling phase, we determined the alignment compensation due to the tertiary mirror from the sensitivity, and derived the tilt-tolerance range to be 0.17 mrad. The off-axis three-mirror telescope, which has better performance than the fore optics of other hyperspectral sensors and is fitted for a small UAV, will contribute to ocean remote-sensing research.

Research on Fabrication of Silicon Lens for Optical Communication by Photolithography Process (포토리소그래피를 통한 광통신용 실리콘 렌즈 제작 및 특성 연구)

  • Park, Junseong;Lee, Daejang;Rho, Hokyun;Kim, Sunggeun;Heo, Jaeyeong;Ryu, Sangwan;Kang, Sung-Ju;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.2
    • /
    • pp.35-39
    • /
    • 2018
  • In order to improve the coupling efficiency, a collimator lens that collects the light emitted from the laser diode at a wide angle to the core of the optical fiber is essential. Glass mold method using a mold is widely used as a collimator lens currently used. Although this method is inexpensive to produce, it is difficult to form precisely and quality problems such as spherical aberration. In this study, the precision of surface processing was improved by replacing the existing glass mold method with the semiconductor process, and the material of the lens was changed to silicon suitable for the semiconductor process. The semiconductor process consists of a photolithography process using PR and a dry etching process using plasma. The optical coupling efficiency was measured using an ultra-precision alignment system for the evaluation of the optical characteristics of the silicon lens. As a result, the optical coupling efficiency was 50% when the lens diameter was $220{\mu}m$, and the optical coupling property was 5% or less with respect to the maximum optical coupling efficiency in the lens diameter range of $210-240{\mu}m$.

Analysis on the TBM Penetration Rates in Extremely Hard Rocks (극경암에서의 전단면터널 굴착속도 분석연구)

  • Park, Chul-Whan;Synn, Joong-Ho;park, Chan;Kim, Min-Kyu;Chung, So-Keul;Kim, Hwa-Soo
    • Tunnel and Underground Space
    • /
    • v.10 no.4
    • /
    • pp.526-532
    • /
    • 2000
  • The uniaxial compressive strength of rock mass is known as the major factor in the assessment of drillability and the optimum excavation design in full-face tunnel excavation by TBM. Referring to worldwide cases, TBM has been applied mostly to the rock mass within the strength range of 80~250 MPa. Recently, a water way tunnel has been constructed as a part of Milyang dam project by TBM within the rock masses where the rock type is mainly granite with some granophyre, hornfels and andesite. Their uniaxial compressive strengths in extended area are estimated higher than 260 MPa. In this paper, the relation between the penetration rate and the rock mass properties is analyzed and TBM application to the very hard rocks is discussed. As a result that three suggestions to predict the TBM net penetration rate are analyzed, NTH method seems a better approach than other methods in the extremely hard rocks. NTH prediction matches with the results of actual values with the variations of 2~20%. Hardness measurement by Schmidt hammer and RMR estimation are carried out along the L = 5.3 km entire TBM tunnel alignment. The net penetration rate measured monthly is shown to be reciprocally proportional to Schmidt rebound hardness and RMR where coefficients of correlation, $R^2$are 0.705 and 0.777 respectively. As a result, they are good quantitative indices for the prediction of TBM net penetration rate in the extremely hard rocks. Magnitude of in-situ stress has a certain effect on TBM performance, and it is required to measure the in-situ stresses in TBM excavation design.

  • PDF

Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber (반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선)

  • Lee, Kwang-Ju;Jeong, Kyung-Seok;Park, Sung-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3626-3632
    • /
    • 2010
  • Some design changes were made to enhance the uniformity of temperature distribution inside the chamber of semiconductor test equipment. The design changes include the installation of adjustable airflow controller inside the chamber, the alignment of the centers of heater and match plate, the change in the size and the shape of holes in match plate base, and the addition of new holes of 2 mm diameter in order to allow airflow directly to the temperature sensors. In order to verify their effects, the temperature distributions inside the chambers were measured using 32 RTD sensors before and after the design changes. The temperature distributions were in the ranges of 87.1 to $91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$) and 89.5 to $90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$) before and after the design changes, respectively. The above temperature distribution after design changes was maintained for longer than 15 minutes, which satisfied the target temperature range of $90{\pm}1^{\circ}C$ for longer than 10 minutes.

Resource Allocation Information Sorting Algorithm Variable Selection Scheme for MF-TDMA DAMA Satellite Communication System (MF-TDMA DAMA 위성통신 시스템에서의 자원할당정보 정렬 알고리즘 가변 선택기법 연구)

  • Park, Nam Hyoung;Han, Joo-Hee;Han, Ki Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • In modern society, as technology has advanced and human life area has expanded, there has been an increasing demand for high-quality voice and video communications services without restrictions on time and place. In response to this demand, satellite communications systems that provide a wide range of communications and that offer multiple access are evolving day by day. In satellite communications systems such as Digital Video Broadcasting - Return Channel Via Satellite (DVB-RCS) and Warfighter Information Network-Tactical (WIN-T), the multi-frequency time division multiple access (MF-TDMA) demand assigned multiple access (DAMA) scheme is used for efficient resource allocation. In this scheme, since the satellite terminals periodically request resources from the network controller, and the network controller dynamically allocates resources, it is necessary to arrange resource allocation information from time to time. Shortening of the alignment time is a more important factor in a satellite communications system in which a long transmission delay occurs due to long-distance transmission and reception. In this paper, we propose a sorting algorithm variable-selection scheme that shortens the sorting time by cross-selecting the sorting algorithm based on a threshold value, while setting the number of frames in the MF-TDMA DAMA satellite communications system as the threshold value.