• Title/Summary/Keyword: Range Alignment

Search Result 255, Processing Time 0.024 seconds

Types & Characteristics of Chemical Substances used in the LCD Panel Manufacturing Process (LCD 제조공정에서 사용되는 화학물질의 종류 및 특성)

  • Park, Seung-Hyun;Park, Hae Dong;Ro, Jiwon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.310-321
    • /
    • 2019
  • Objectives: The purpose of this study was to investigate types and characteristics of chemical substances used in LCD(Liquid crystal display) panel manufacturing process. Methods: The LCD panel manufacturing process is divided into the fabrication(fab) process and module process. The use of chemical substances by process was investigated at four fab processes and two module processes at two domestic TFT-LCD(Thin film transistor-Liquid crystal display) panel manufacturing sites. Results: LCD panels are manufactured through various unit processes such as sputtering, chemical vapor deposition(CVD), etching, and photolithography, and a range of chemicals are used in each process. Metal target materials including copper, aluminum, and indium tin oxide are used in the sputtering process, and gaseous materials such as phosphine, silane, and chlorine are used in CVD and dry etching processes. Inorganic acids such as hydrofluoric acid, nitric acid and sulfuric acid are used in wet etching process, and photoresist and developer are used in photolithography process. Chemical substances for the alignment of liquid crystal, such as polyimides, liquid crystals, and sealants are used in a liquid crystal process. Adhesives and hardeners for adhesion of driver IC and printed circuit board(PCB) to the LCD panel are used in the module process. Conclusions: LCD panels are produced through dozens of unit processes using various types of chemical substances in clean room facilities. Hazardous substances such as organic solvents, reactive gases, irritants, and toxic substances are used in the manufacturing processes, but periodic workplace monitoring applies only to certain chemical substances by law. Therefore, efforts should be made to minimize worker exposure to chemical substances used in LCD panel manufacturing process.

Design of Sub-array Receiver for Active Phase Array Radar (능동위상배열 레이더 부배열 수신기 설계)

  • Yi, Hui-min;Kim, Do-hoon;Han, Il-tak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.5
    • /
    • pp.568-573
    • /
    • 2019
  • Modern Radars are evolving into MFRs which can search multiple targets simultaneously and then track them. Additionally they should be able to avoid some external jamming signals. Applying to these MFRs, Antennas should be able to perform DBF including to not only real-time beam steering but also multi-beam forming simultaneously. And they can cancel the beam at the specific direction. In this paper, we describe the implementation of sub-array type antenna hardware which can be applying DBF. Also we propose the modified amplitude aperture distribution for suppressing the side lobe level and explain the sub-array receiver design with amplitude tapering. It consists in making the amplitude weighting in 2 steps. In order to compare two weighting cases, we investigate the G/T performance for the array antenna. At the conclusion, we make a comparative study for the dynamic range of every sub-array receiver and present the hardware implementation that is more advantageous for sub-array alignment and calibration in DBF.

Haraldiophyllum hawaiiense sp. nov. (Delesseriaceae, Rhodophyta): a new mesophotic genus record for the Hawaiian Islands

  • Paiano, Monica O.;Huisman, John M.;Cabrera, Feresa P.;Spalding, Heather L.;Kosaki, Randall K.;Sherwood, Alison R.
    • ALGAE
    • /
    • v.35 no.4
    • /
    • pp.337-347
    • /
    • 2020
  • Haraldiophyllum hawaiiense sp. nov. is described as a new mesophotic alga and a new genus record for the Hawaiian Islands. Six specimens were collected at a depth range of 81-93 m from Papahānaumokuākea Marine National Monument, and their morphology investigated, as well as molecular phylogenetic analyses of the plastidial ribulose-1,5-bisphosphate carboxylase-oxygenase large-subunit (rbcL) gene and a concatenated alignment of rbcL and nuclear large-subunit rRNA gene (LSU) sequences. Phylogenetic analyses supported H. hawaiiense sp. nov. as a distinct lineage within the genus Haraldiophyllum, and sister to a large clade containing the type species, H. bonnemaisonii, as well as H. crispatum and an undescribed European specimen. The six Hawaiian specimens were shown to be identical, but unique among other species of the genus as well as the recently segregated genus Neoharaldiophyllum, which comprises half of the species previously included in Haraldiophyllum. The vegetative morphology of H. hawaiiense sp. nov. resembles Neoharaldiophyllum udoense (formerly H. udoensis); however, no female or post-fertilization structures were found in the Hawaiian specimens to allow a more comprehensive comparison. The molecular phylogenies demonstrate that Haraldiophyllum is paraphyletic, suggesting either that the Myriogrammeae tribe includes undescribed genera, including Haraldiophyllum sensu stricto, or that Neoharaldiophyllum species should be transferred into the genus Haraldiophyllum. However, based on vegetative morphology and molecular analyses, and pending resolution of this taxonomic issue, the Hawaiian specimens are placed within the genus Haraldiophyllum. This new record for the Hawaiian Islands highlights the novel biodiversity from mesophotic depths, reaffirming the need for further investigation into the biodiversity of Mesophotic Coral Ecosystems.

Effects of Complex Korean Medicine Treatment on a Patient with Knee Pain and Ankylosis Following a Distal Femur Osteotomy: A Case Report

  • Park, Han Bin;Heo, Eun Sil;Yoo, Dong Hwi;Jang, Won Suk;Kwon, Oh Bin;Choi, Ki Won;Kwon, Min Jin;Kim, Tae Ju;Jang, Seon Woo;Kwon, Oh Hoon
    • Journal of Acupuncture Research
    • /
    • v.39 no.2
    • /
    • pp.134-138
    • /
    • 2022
  • Distal femur osteotomy (DFO) is a controlled surgical break of the femur performed to allow realignment of the limb. Redistribution of the load aims to correct the abnormal mechanical weight-bearing axes in patients with abnormal alignment of the lower extremities, and degenerative changes in the knee joint. This report describes a complex Korean medicine treatment for a patient complaining of knee pain and stiffness following a DFO. Post-operative care for the patient lasted 78 days with treatment including pharmacopuncture, acupuncture, herbal medicine, cupping therapy, and physiotherapy. The effectiveness of the treatments was evaluated using the numerical rating scale, range of motion of the knee, and by physical examination. After treatment, these evaluation indicators improved, suggesting that the complex Korean medicine treatment received by the patient was an appropriate treatment for knee pain and stiffness following a DFO.

Manufacturing and Characteristic Evaluation of Free space Optical Communication Devices in 5G Mobile Base Stations for Emergency Disaster Response (긴급재난 대응용 5G 이동 기지국을 위한 대기공간 광통신 장치의 제작과 특성평가)

  • Jin-Hyeon Chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.131-138
    • /
    • 2023
  • In this paper, a free space optical communication device that can be used in a mobile base station of several km or less was fabricated and its characteristics were investigated. To overcome the loss due to atmospheric transmission, an optical fiber amplifier (EDFA) with an output of 23 dBm or more was used. In order to increase the focusing speed and miniaturization of the laser beam, an optical lens was manufactured, and a transmission lens was designed to have beam divergence within the range of 1.5 to 1.8 [mrad]. A PT module that controls PAN/TILT was fabricated in order to reduce pointing errors and effective automatic alignment between transceiver devices. In this study, Reed-Solomon (RS) code was used to maintain the transmission quality above a certain level. It was manufactured to be able to communicate at a wireless distance of 300m in a weather situation with visibility of 300m. For performance measurement, it was measured using BERT and eye pattern analyzer, and it was confirmed that BER can be maintained at 2.5Gbps.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

Immediate Effects of High-Frequency Diathermy on Neck, Shoulder Alignment, Pain and Function in Adults with Forward Head Posture (고주파심부투열 치료가 앞쪽머리자세를 가진 성인의 자세정렬, 통증 그리고 기능에 미치는 즉각적인 효과)

  • Young-Joo Cha;Kyoung-Tae Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.143-153
    • /
    • 2024
  • Purpose : Forward head posture (FHP), characterized by the anterior positioning of the head relative to the spine, is a common postural deviation that can lead to neck pain, reduced mobility, and muscle imbalances. Recently, high-frequency deep heat therapy (HFDT) has been gaining attention for the intervention of FHP. This research aims to investigate the efficacy of HFDT in comparison to instrument assisted soft-tissue mobilization (IASTM) for treating FHP among 30 young adults. Methods : Participants were randomly assigned to either the HFDT or IASTM group. The study focused on examining changes in neck joint mobility, pain thresholds, rounded shoulder distance, lower trapezius muscle strength, and neck dysfunction. Measurements were taken before and after the interventions. Paired t-tests were used for within-group analyses, and independent t-tests were employed for between-group comparisons. The statistical significance level α was set to .05. Results : Statistically significant improvements were observed across all measured parameters in both groups (p<.05). The HFDT group showed significantly greater enhancements in neck joint mobility, pain thresholds, rounded shoulder distance, lower trapezius muscle strength, and neck dysfunction parameters. Specifically, HFDT was more effective than IASTM in improving neck joint mobility, right upper trapezius pain threshold, left rounded shoulder distance, and right lower trapezius strength. The only exceptions were neck flexion range of motion, left upper trapezius pain threshold, right rounded shoulder distance, and left lower trapezius strength, where no significant differences were found between the groups. Conclusion : The findings suggest that HFDT, by combining the benefits of high-frequency therapy and manual therapy, effectively alleviates upper trapezius muscle pain and tension, enhances neck mobility, and strengthens lower trapezius muscles. Thus, HFDT could be considered a valuable intervention for clinicians aiming to address FHP and associated musculoskeletal problems.

Phytophthora palmivora RPA1, a Homolog of Phytophthora infestans RPA190, is Irrelevant to Metalaxyl Resistance in Phytophthora palmivora Causing Root and Stem Rot of Durian in Thailand

  • Kamonwan Sichai;Patcharin Nianwichai;Nutsuda Taraput;Veeranee Tongsri;Pattavipha Songkumarn
    • The Korean Journal of Mycology
    • /
    • v.52 no.2
    • /
    • pp.73-96
    • /
    • 2024
  • Root and stem rot caused by Phytophthora palmivora is one of the most serious diseases affecting durian production in Thailand where metalaxyl, an effective fungicide against oomycetes, has been used extensively for a long period to control this disease. Although field isolates of P. palmivora resistant to metalaxyl exist in Thailand, a molecular basis for P. palmivora has not yet been elucidated regarding metalaxyl resistance. The current study tested whether P. palmivora RPA1 (the DNA-directed RNA polymerase I subunit gene), a homolog gene of RPA190 associated with metalaxyl resistance in some isolates of Phytophthora infestans, had a role in the resistance mechanism toward metalaxyl. In total, 40 durian-derived isolates of P. palmivora were assessed for metalaxyl sensitivity using a mycelial growth inhibition assay. The effective concentrations for 50% mycelial growth inhibition values for all isolates tested were in the range 0.01-872.88 mg/L. The isolates were clustered into three groups: sensitive (n=23), moderately resistant (n=11), and resistant (n=6) groups. No polymorphism was revealed based on multiple alignment analysis of the amino acid sequences translated from the corresponding DNA sequences in the region of RPA1 of the metalaxyl-sensitive (n=5), moderately resistant (n=2), and resistant isolates (n=6). Furthermore, investigation of the RPA1 expression among these representative isolates (n=3, each group) indicated that RPA1 expression may not be involved in the regulation of P. palmivora resistance to metalaxyl. Based on this line of evidence, there was no detected relationship regarding metalaxyl resistance and P. palmivora RPA1.

Optical Approach for Increasing the Resolution of Displayed Multi-view Image from Projection Type of Auto-stereoscopic 3D Display System by Adopting a Commercial Spherical Lenticular Lens Sheet (프로젝션 기반 무안경 방식 멀티뷰 3D 디스플레이에서 구면 렌티큐라 렌즈 시트를 이용하여 재생된 입체영상의 해상도를 증가시키는 광학적 접근 방법)

  • Sohn, Young-Sub;Kim, Sung-Kyu;Sohn, Kwanghoon;Lee, Kwang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2012
  • Multi-view 3D displays based on a limited number of pixels have the problem that the stereo-scopic image has a low resolution because of increasing view number. To solve the problem of low resolution, we propose an optical approaching method that focuses the width of a unit pixel by using a commercial spherical shape lenticular lens sheet and increases the effective resolution by increasing the number of sources of light in the multi-view 3D display system based on projection type. The method was performed in such an order that several main derivable parameters were defined, and, through the theoretical and experimental result, the value of the contractible unit pixel width and the scalable effective resolution was derived in a given system environment. As a result, for the case that the ray of light from the projector transmitted the 25 LPI lenticular lens sheet which has the pitch size 1.016 mm, the focused unit pixel width was 0.19 mm and the scalable effective resolution was, at most, 5 times wider than the original one. In addition, the range of depth of focus was 1.496 mm, which shows us the range of thickness tolerances of commercial spherical shape lenticular lens sheet and sufficient optical alignment tolerances.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF