• Title/Summary/Keyword: Range Alignment

Search Result 255, Processing Time 0.027 seconds

High-quality ZnO nanowire arrays directly synthesized from Zn vapor deposition without catalyst

  • Khai, Tran Van;Prachuporn, Maneeratanasarn;Choi, Bong-Geun;Kim, Hyoun-Woo;So, Dae-Sup;Lee, Joon-Woo;Park, No-Hyung;Huh, Hoon;Tung, Ngo Trinh;Ham, Heon;Shim, Kwang-Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.4
    • /
    • pp.137-146
    • /
    • 2011
  • Vertically well-aligned ZnO nanowire (NW) arrays were synthesized directly on GaN/sapphire and Si substrate from Zn vapor deposition without catalysts. Experimental results showed that the number density, diameter, crystallinity and degree of the alignment of ZnO NWs depended strongly on both the substrate position and kind of the substrates used for the growth. The photoluminescence (PL) characteristics of the grown ZnO NW arrays exhibit a strong and sharp ultraviolet (UV) emission at 379 nm and a broad weak emission in the visible range, indicating that the obtained ZnO NWs have a high crystal quality with excellent optical properties. The as-grown ZnO NWs were characterized by using scanning electron microscopy (SEM), high resolution transmission electronic microscopy (HR-TEM), and X-ray diffraction (XRD).

Omnipresence of Strain Localization in Soils (흙의 변형국지화 편재에 관한 연구)

  • 권태혁;조계춘
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.199-210
    • /
    • 2003
  • The development of strain localization within shear zones is frequently observed during soil deformation. In fact, the phenomenon appears to be more often the norm rather than the exception. Conceptually, any soil condition that renders negative work increment is prone to localization. In this study, a broad range of soil and loading conditions are investigated to test this criterion, including: dilative soil subjected to drained shear (standard case), contractive soil sheared under undrained conditions, cavitation in dilative soil in undrained shear, inhomogeneous soils, particle alignment in contractive soils made of platy particles, soils that experience particle crushing, and the shear of low-moisture and/or lightly cemented loose soils. Unique specimens and test procedures are designed to separately test each of these soil conditions in the laboratory According to experimental test results, soil specimens with post-peak strain softening behavior are prone to progressive failure, localization of deformations, and shear banding. The state of stress, the soil density, inherent mechanical and geometrical properties of soil particles, low water content, and heterogeneity can contribute to triggering strain localization. Considering all possible cases of localization, the best method to obtain the critical state line in the laboratory is to use contractive homogeneous specimens subjected to drained shear.

A CASE OF BILATERAL SUPERNUMERARY TEETH IN THE MANDIBULAR INCISOR REGION : A CASE REPORT (하악 전치부에 양측성으로 발생한 과잉치의 치험례)

  • Jeong, Nae-Jeong;Kim, Jung-Wook;Kim, Chong-Chul;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.142-145
    • /
    • 2001
  • Supernumerary tooth is one of the abnormalities in tooth number. Supernumerary tooth result from excessive proliferation of dental lamina and incidence reports identify a range of $0.3\sim0.8%$ in primary dentition, $1.0\sim3.5%$ in permanent dentition with males being affected twice as frequently as females, maxilla nine times as frequently as mandible The incidence is more in anterior tooth region than in posterior region. The most common supernumerary tooth is the mesiodens, which located between maxillary central incisors. The occurrence is very rare in the incisor region of mandible and the reports on incidence is 2%. In this case, there were two supernumerary teeth in the mandibular region and we could acquire normal alignment of mandibular incisors by extraction and orthodontic treatment.

  • PDF

The Performance of Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Moon, Bongkon;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Ko, Kyeongyeon;Kim, Mingyu;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared spectro-photometric instrument optimized to the first Next Generation of small satellite (NEXTSat-1). The off-axis optics was developed to cover a wide field of view with 2 deg. ${\times}$ 2 deg. as well as a wide wavelength range from 0.95 to $2.5{\mu}m$. Considering the simple alignment scheme, afocal system was adapted in the optical components. The mechanical structures were tested under the space environment. We have obtained the accurate calibration data using our test facilities under the operational condition. After the final integration of flight model into the satellite, the communication with the satellite and the functional test were passed. The NISS will be launched in early 2018. During around 2-year operation, the spectro-photometric survey covering more than 100 square degree will be performed. To achieve the major scientific objectives for the study of the cosmic star formation in local and distant universe, the main observational targets will be nearby galaxies, galaxy clusters, star-forming regions and low background regions. Here, we report the final performance of the flight model of the NISS.

  • PDF

Manufacturing Functional Nano-Composites by Using Field-Aided Micro-Tailoring Manipulation (Field-Aided Micro-Tailoring에 의한 기능성 나노복합재 제조)

  • Cho, Hee-Keun;Rhee, Juhun;Sim, Eun-Sup
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.178-185
    • /
    • 2012
  • One of a unique technique in manipulating a multifunctional composite is demonstrated in this study. An electric field is applied to a liquid suspension in order to align the inclusions along with the direction electric field. This is called FAiMTa(Field Aided Micro Tailoring). It makes orthotropic polymer composites by arranging the micro and/or nano size particle inclusions in chain-line formation. Several kinds of particles such as $Al_2O_3$, graphite, CNT(Carbon Nano Tube), W(Tungsten) are tested to verify the effectiveness of the FAiMTa. The particles redistributed in an epoxy suspension and their coupons show that mechanical and thermal properties of orthotropic and random composites containing those particles depend on the trend of particles' alignment. The micro-images of the functional composite from FAiMTa have been captures and their physical properties demonstrate their wide-range and state-of-the-art application for advanced multifunctional composites.

Development of Contact-Type Thickness Measurement Machine using LVDT Sensors (LVDT센서를 이용한 접촉식 두께자동측정기 개발)

  • Shin, Ki-Yeol;Hwang, Seon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • In this study, we developed an automated contact-type thickness measurement machine that continuously and precisely measures the thickness of a PCB module product using multi-LVDT sensors. The system contains a measurement part to automatically measure the thickness in real time according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The sensors were calibrated before assembly in the measuring machine, and precision and accuracy performance tests were also performed to reduce uncertainty errors in the measurement machine. In the calibration test, the precision errors of the LVDT sensor were determined to be $1-3{\mu}m$ as 0.1% at the measuring range. A measurement error of 0.8 mm and 1.0 mm thickness test standards were found to be $1{\mu}m$ and $4{\mu}m$, and the standard deviations of two 1.0 mm products were measured as $14{\mu}m$ and $8{\mu}m$, respectively. In the measurement system analysis, the accuracies of test PCB standards were found to be $2{\mu}m$ and $3{\mu}m$, respectively. From the results of gage repeatability and reproducibility (R & R) crossed, we found that the machine is suitable for the measurement and process control in the mass production line as 7.92% of total gage R & R and in seven distinct categories. The maximum operating speed was limited at 13 pcs/min, showing a value good enough to measure.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Pelvic, Hip, and Knee Kinematics of Stair Climbing in People with Genu Varum

  • Chae, Yun Won;Park, Seol;Park, Ji Won
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.14-22
    • /
    • 2018
  • Purpose: This study examined the effects of the lower limb alignment on the pelvis, hip, and knee kinematics in people with genu varum during stair walking. Methods: Forty subjects were enrolled in this study. People who had intercondylar distance ${\geq}4cm$ were classified in the genu varum group, and people who had intercondylar distance <4cm and intermalleolar distance <4cm were placed in the control group. 3D motion analysis was used to collect the pelvis, hip, and knee kinematic data while subjects were walking stairs with three steps. Results: During stair ascent, the genu varum group had decreased pelvic lateral tilt and hip adduction at the early stance phase and decreased pelvic lateral tilt at the swing phase compared to the control group. At the same time, they had decreased minimal hip adduction ROM at the early stance and decreased maximum pelvic lateral tilt ROM and minimum hip rotation ROM at the swing phase. During stair descent, the genu varum group had decreased pelvic lateral tilt at the early stance and decreased pelvic lateral tilt and pelvic rotation at the swing phase. In addition, they had decreased pelvic frontal ROM during single limb support and increased knee sagittal ROM during the whole gait cycle. Conclusion: This study suggests that a genu varum deformity could affect the pelvis, hip and knee kinematics. In addition, the biomechanical risk factors that could result in the articular impairments by the excessive loads from lower limb malalignment were identified.

A Study on the Performance Evaluation and Use Status of Grid (격자의 성능평가와 이용실태에 관한 연구)

  • Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk;Oh, Hyun-Joo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, In-Ja;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 1994
  • We have conducted on experiment with a purpose to evaluate the performance of grids being used at hospitals in Seoul and adjacent cities of Seoul. The results are as follows; Reality of the grids use 1. The focused grids were 105 and the parallel grids were 6 among 111 grids subject to experimenting. 2. The grid interspace material was aluminium of 94 and the remains were wood and bakelite. 3. The umber of Korean products from five companies was 33 and the one of the foreign products was 34 from companies. The physical properties have been examined by the notice of Department of Health and Social Affairs. 4. The intensity of secondary radiation was the highest in 5 : 1 grid ratio. 5. The Bucky factor increased with the increase of grid ratio. The selectivity, the grid improvement factor of grids also increased with increase of the grid ratio. However, with 6 : 1 grid ratio those factors were decreased exceptionally. In measurement of grid density with screen determiners and the beam alignment. 6. In evaluation the results were satifisfied within, 20%. 7. The value of the scale and the value of measurement were within the range of standard deviation, but the value of 103 lines were outranged from the standard deviation with all grid ratio except of 6 : 1 grid ratio.

  • PDF

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).