• 제목/요약/키워드: Random Pulse Position Modulation

검색결과 17건 처리시간 0.024초

Random Pulse Position PWM 방식을 적용한 IPMSM 기반 차세대 고속전철 구동 인버터 시스템의 고조파 저감 (Reducing Harmonics of the Next-generation High-speed Railway Inverter System by Random Pulse Position Modulation Technique based on Space Vector Modulation)

  • 이상현;진강환;김성제;노애숙;김윤호
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.94-101
    • /
    • 2012
  • In this paper, The Next Generation High Speed Railway inverter system based on IPMSM drives using Random Pulse Position Modulation is proposed to reduce electromagnetic noise. To verify the validity of study, the simulator for the proposed system is designed and impplemented. Simulation program is developed using Matlab/Simulink. The simulation results of the proposed system was compared with the system using conventional method. The results show that the voltage and current harmonics of the proposed Next Generation High Speed Railway Inverter system. significantly decrease and spread into wide band area by the proposed Random Pulse Position modulation technique based on Space Vector Modulation method.

Random Position PWM을 이용한 유도전동기의 가청 스위칭 소음 저감 (Reduction of Audible Switching Noise in Induction Motor Drives Using Random Position PWM)

  • 나석환;임영철
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.287-297
    • /
    • 1998
  • RPWM(Random Pulse Width Modulation)은 인버터의 스위칭 주파수를 랜덤하게 변화 시킴으로써 전압, 전류의 고조파 및 소음의 스펙트럼을 광대역에 분산시키는 PWM 기법이다. 스위칭 주파수 또는 펄스의 위치를 랜덤하게 변화시켜 고조파의 불연속적인 이산치 성분을 넓은 영역에 분산시켜 EMI, 진동 등에 좋은 효과를 낼 수 있을 뿐만 아니라, 전력소자의 스위칭에 의해 발생하는 가청 스위칭 소음을 저감할 수 있으므로 근래에 매우 각광 받고 있다. 본 연구에서는 펄스의 위치를 랜덤하게 함으로써 가청 스위칭 소음을 저감할 수 있는 새로운 RPPWM(Random Position Pulse Width Modulation) 방식의 제안 및 구현하였다. 제안된 방식은 각 3상 펄스들의 위치를 변조 구간 내의 임의의 위치에 랜덤하게 배치함으로써 RPWM을 구현하는 방식이다. 이를 위하여 16bit 공성능 마이크로 컨트롤러의 C167을 사용하여, 공각 벡터 변조에 의하여 각 변조 구간에서의 듀티비를 구한 후, 랜덤수 발생기를 이용하여 균일한 분포로 각 상의 펄스를 배치하였다. 그리고 제안된 RPPWM을 이용하여 실험한 결고, 전압, 전류 및 소음의 스텍트럼이 광대역화 되어 전력소자의 스위칭에 의해 발생하는 전동기의 가청 스위칭 소음이 현저히 저감 됨을 확인하였다.

  • PDF

Acoustic Noise Reduction of Three-Phase SRM with Random Pulse Position PWM and Random Turn-on/off Angle Control

  • Khai, Nguyen Minh;Shin, Duck-Shick;Jung, Young-Gook;Lim, Young-Cheol
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2006
  • This paper describes a new method using random modulated strategies for switched reluctance machines. The proposed method is combined random turn-on, turn-off angle technique and random pulse width modulation technique. The purpose of this proposed method is to decrease harmonic spectrum, and thus reduce the emitted acoustical noise. A random generator is generated by linear congruential generator (LCG) using random pulse position (RPP) scheme. Simulation results show that the harmonic intensity of proposed method is better than that of conventional method.

  • PDF

개선된 Randomized Pulse Position PWM기법을 이용한 3상 유도 전동기의 고조파 영향 (Improved Randomized Pulse Position PWM Scheme Based on The three-phase Indui Drive To Reduce the Harmonic Effect)

  • 하상목;한우용;이창구;김병우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1169-1171
    • /
    • 2002
  • In this paper, RFRPP(Random Frequency Randomized Pulse Position ) PWM for three-phase voltage-controlled inverters is proposed. The LLPWM(Lead-Lag PWM) techinquc is that three switching pulses are located randomly back and forth in each switching interval. But with the restriction of random distribution, the harmonic spectrum cannot be dispersedly and continuously distributed. This paper calculates the duty ratio of the switching pulse firstly. Second, the switching pulses are located randomly in the switching interval. Third, the fixed switching frequency of the space vector modulation is randomly varied. To verify the validity of the proposed technique, simulation study is tried using Matlab/Simulink. When a proposed techniquc is employed, the harmonic spectrum of the inverter output voltagc varies from one cycle to the next and the EMI(Electromagnetic Interference) and resonant vibration are greatly alleviated.

  • PDF

새로운 공간벡터 Random Position PWM기법 (A New Space Vector Random Position PWM Scheme)

  • 김회근;임영철;나석환;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.168-174
    • /
    • 2001
  • In this paper, a new space vector RPPWM (Random Position PWM) is proposed. In the proposed RPPWM, each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed RPPWM, simulation study was tried using Matlab/simulink. The main model described in Simulink block diagrams includes the space vector modulation block, pulse position randomization block, inverter block, 3 phase induction motor block, and so on. By the simulation study, the harmonics of the output voltage, and the current of inverter are predicted in different PWM methods- SVPWM, LLPWM, proposed RPPWM.

  • PDF

모터 구동 장치의 가청 소음 저감을 위한 새로운 3상 Lead-Lag 랜덤 펄스 위치 PWM 기법 (A New Three-Phase Lead-Lag Random Pulse Position PWM Scheme for Decreasing Audible Acoustic Noise of Motor Drives)

  • 위석오;정영국;임영철;나석환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권7호
    • /
    • pp.387-398
    • /
    • 2002
  • In this paper, a new Three-Phase Lead-Lag Random Pulse Position PWM(LL-RPWM) scheme is proposed and implemented for decreasing audible acoustic noise of motor drives. In the proposed RPWM(Random PWM), each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed LL-RPWM, the simulation and experimental study was tried. Along with the randomization PWM pulses, the space vector modulation is also executed in the C167 micro-controller. The simulation and experimental results show that the voltage and current harmonics are spread to a wide band area and that the audible acoustic noise is reduced by the proposed RPWM method.

인버터 구동 시스템을 위한 새로운 공간벡터 Random PWM기법 (A New Space Vector Random PWM Scheme for Inverter Fed Drive Systems)

  • 나석환;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.525-537
    • /
    • 2001
  • 본 연구에서는 펄스의 위치를 랜덤하게 함으로써 효율적은 RPWN (Random PWM)을 구현할 수 있는 새로운 공간 벡터 RPPWM(Random Position PWM)방식을 제안하였다. 제안한 방식은 마이크로 컨트롤로 적용하기 쉬운 공간벡터 변조에 의하여 각 상의 듀티비를 연산한 다음, 스위칭 순서를 유지하며 각 3상 펄스들의 위치를 변조구간내에서 임의의 위치에 랜덤하게 배치함으로써 RPWM을 구현하는 방식이다. 제안된 방법의 타당성을 검증하기 위하여 MATLAB/SIMULINK를 이용하여 펄스위치의 랜덤화 공각벡터 변조, 인버터 및 3상 유도전동기를 포함하는 전체 시스템을 모델화하였다. 종전의 공각벡턱 PWM 그리고 제안된 RPPWM에 의한 인버터 출력 전압 전류의 고조파 성분을 시뮬레이션에 의하여 비교 검토하였으며 제안된 방법의 유용성을 입증할 수 있었다.

  • PDF

REDUCTION OF AUDIBLE SWITCHING NOISE IN INDUCTION MOTOR DRIVES USING RANDOM POSITION PWM

  • Na, Seok-Hwan;Wi, Seok-Oh;Lim, Young-Cheol;Yang, Seung-Hak
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.316-319
    • /
    • 1998
  • RPWM(Random Pulse Width Modulation) is a switching technique to spread the voltage and current harmonics on the wide frequency area. Using randomly changed switching frequency of the inverter, the power spectrum of the electromagnetic acoustic noise cab be spread to the wide-band area. The wide-band noise is much more comfortable and less annoying than the narrow-band one. So RPWM have been attracting an interest as an excellent method for the reduction of acoustic noise on the inverter drive system. In this paper a new RPPWM (Random Position PWM) is proposed and implemented. Each of three pulses is located randomly in each switching interval. Along with the randomization of PWM pulses, the space vector modulation is executed in the C167 microcontroller also. The experimental results show that the voltage and current harmonics were spread to wide band area and that the audible switching noise was reduced by proposed RPPWM method.

  • PDF

새로운 2상 랜덤 펄스 위치 PWM기법 (A New Two-Phase Random Pulse Position PWM Scheme)

  • 魏 昔 吾;鄭 榮 國;羅 碩 煥;任 永 徹
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.194-204
    • /
    • 2002
  • 본 연구에서는 각 상의 PWM 펄스를 개별적으로 랜덤하게 위치시킬 수 있는 새로운 2상 공간벡터 RPWM (Random PWM) 기법을 제안하고 있다. 제안된 방식은 각 2상 펄스들을 변조 구간 내에서 임의의 위치에 랜덤하게 배치하고 이를 기준으로 한 인버터 스위칭에 의해 고조파의 스펙트럼을 광대역화 하는 RPWM 기법이다. 제안된 방법의 타당성을 검증하기 위하여, 16비트 고성능 마이크로 콘트롤러Cl67 기반의 실험을 수행하였다 제안된 2상 RPWM에 의한 인버터 출력 선간 전압과 직류 링크 전류의 고조파 스펙트럼 및 모터의 가청 스위칭 소음 저감효과를 종전의 방식과 비교 검토하였으며, 제안된 방법의 우수성을 입증할 수 있었다.

옵셋 전압을 이용한 일정 스위칭 주파수의 Random PWM 기법 (A Novel Random PWM Technique with a Constant Switching Frequency Utilizing an Offset Voltage)

  • 김도겸;김상훈
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.67-74
    • /
    • 2017
  • This study proposes a novel random pulse-width modulation (PWM) technique with a constant switching frequency utilizing a random offset voltage. The proposed PWM technique spreads switching harmonics by varying the position of an active voltage vector without a switching frequency variation. The implementation of the proposed PWM technique is simple because it does not require additional hardware and complex algorithm. The proposed random PWM technique is compared with the conventional PWM technique on the factors of harmonic spectrum, total harmonic distortion, and harmonic spread factor to confirm the harmonic spread effect. The validity of the proposed method is verified by simulations and experiments on a three-phase inverter drive system.