• Title/Summary/Keyword: Rainwater utilization system

Search Result 16, Processing Time 0.022 seconds

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

A Study on Efficient Improvement Method of Rainwater Utilization Facilities in Jeju Island (제주지역 빗물이용시설의 효율적 개선방안 연구)

  • Park, Won-Bae;Moon, Deok-Cheol;Koh, Gi Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2012
  • This study is to suggest a few efficient ways of rainwater utilization, through monitoring and analyzing 143 rainwater storage systems and 110 artificial recharge systems, which are installed in the recommended facilities by law, among the rainwater harvesting systems in Jeju Island. In the case that catchment facilities are damaged, rainwater could be contaminated by leaves and debris so that the rates of rainwater usages come to be lower. It is possible that contaminated rainwater could contaminate artificial recharge wells or rainwater discharging out of the rainwater harvesting system could result in flood and damage for the downgradient area. For maintaining high quality of rainwater and increasing rainwater utilization rate, it is necessary to install screening facilities and purification plant functioning precipitation and filtration. Also, in order to efficiently preclude the overflowing rainwater exceeding storage capacity, it is recommended to associate rainwater storage tanks with artificial recharge well or infiltration trench facilities.

A Study on Rainwater Utilization for Environmental Friendly Housing Complex Plan in Korea and Foreign Country (친환경적 단지조성을 위한 국내외 우수이용사례 및 적용방안에 관한 연구)

  • Cho, Kyung-Min;Lee, Tae-Goo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.195-200
    • /
    • 2003
  • The purpose of this study is to establish the rainwater Utilization for the housing complex through the using rainwater, infiltration and detention. This study focused on the following items. 1) Legal basic conditions for the rainwater utilization in Germany 2) Case study on the rainwater management with examples. As the results of this study, it is necessary to implement these rainwater management system in laws, legal norms and technical regulation.

  • PDF

A Study on the Rainwater Quality Monitoring and the Improvement, Collection and Storage System (빗물 집수 및 저장 시스템 개선과 수질 분석 모니터링)

  • Kim, Chul-Kyung
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.

Assessment of Roof-rainwater Utilization System and Drought Resistance of Ground Cover Plants (지피식물을 이용한 우수저장형 옥상녹화 시스템 및 식물 내건성 평가)

  • Kang, Tai-Ho;Zhao, Hong-Xia
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.5
    • /
    • pp.1-8
    • /
    • 2013
  • In order to evaluate 2 extensive green roof systems(Sedum Box Roof System and Roof-rainwater Utilization System) for urban greening and select ground-cover plants, which can adapt well to the drought tolerance in an extensive green roof system on 12 species. This study was carried out in order to suggest an experimental base in assessment of the Green Roof-rainwater Utilization System and selecting the drought resistance of plants. Adopting the natural drought method, this paper studies the drought resistance of 12 kinds of ground cover plants. The drought-resistance of ground cover plants subjected to dry processing time were evaluated using relative water content on leaves, relative electric conductivity and chlorophyll content in 12 kinds of plants, and the relation between soil water content under drought stress. Drought resistance of the plants were subject to rooftop drought resistance treatments. The result showed that with the increase of stress time, the relative water content and chlorophyll content on leaves were in a downward trend while the relative electric conductivity was in an upward trend. Among the 12 species of ground cover plants, excluding Pulsatilla koreana, Ainsliaea acerifolia was selected for rooftop plants because they showed resistance to drought strongly and took adaptive ability. These results showed that drought tolerance of plants in Roof-rainwater Utilization System were stronger than the Sedum Box Roof System. Therefore, the Roof-rainwater Utilization System is good for plants. It helps them adapt well to the drought tolerance in rooftops and can be used for urban greening.

Hydrological Evaluation of Rainwater Harvesting: 2. Hydrological Evaluation (빗물이용의 수문학적 평가: 2. 수문학적 평가)

  • Kim, Kyoungjun;Yoo, Chulsang;Yun, Zuhwan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.230-238
    • /
    • 2008
  • This study evaluated the economic aspect of the rainwater harvesting facilities by hydrologically analyzing the inflow, rainwater consumption, rainfall loss, tank storage, and overflow time series to derive the net rainwater consumption and the number of days of rainwater available. This study considers several rainwater harvesting facilities in Seoul National University, Korea Institute of Construction Technology and Daejon World Cup Stadium and the results derived are as follows. (1) Increasing the water consumption decreases the number of days of rainwater available. (2) Due to the climate in Korea, a larger tank storage does not increase the amount and the number of days of water consumption during wet season (June to September), but a little in October. (3) Economic evaluation of the rainwater harvesting facilities considered in this study shows no net benefit (private benefit). (5) Flood reduction effect of rainwater harvesting facilities was estimated very small to be about 1% even in the case that 10% of all the basin is used as the rainwater collecting area.

Comparative Study of the System for Decentralized Rainwater Management in Korea and Germany (한국과 독일의 분산식 빗물관리를 위한 제도 비교 연구)

  • Han, Young-Hae;Lee, Tae-Goo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.4 s.117
    • /
    • pp.84-95
    • /
    • 2006
  • This study begins by examining the reason for the lack of urban planning that takes the water cycle into consideration. While there are institutions that support environmentally friendly development or smooth water circulation, these designs are not reflected in planning nor in the real world. After reviewing foreign case studies, policy suggestions and possible policy implications for Korea are derived. In Korea, there is not a sufficient level of relevant laws or institutions systematically established to make it possible to deal with rainwater in a decentralized way. Instead, facility standards or guidelines are considered separately for the control of water and for preventing natural disasters. And even though an environmentally friendly approach is stipulated in relevant laws in terms of spatial planning, there are no planning systems or implementation tools to actualize this kind of approach. The factors that make decentralized rainwater management possible in urban planning are analyzed based on the case study of Germany. Germany requires developers to plan in order to achieve ecological urban development. In addition, as a detailed implementation tool to promote conservation of the water cycle, the law provides for various kinds of measures such as restrictions on the proportion of impervious surface area according to the use of the land, required compensation measures for environmental degradation following development, introduction of a fee for rainwater runoff and the establishment of ecological landscape planning. The actual reason these measures can be implemented however is the provision of planning guidelines and design criteria for rainwater utilization, absorption and containment, and the construction of a database for various environmental information.

Analysis on Rainwater Harvesting System as a Source of Non-Potable Water for Flood Mitigation in Metro Manila (마닐라의 홍수저감을 위한 잡용수 대체자원으로서의 가정용우수저류시설 분석)

  • Necesito, Imee V.;Felix, Micah Lourdes A.;Kim, Lee-Hyung;Cheong, Tae Sung;Jeong, Sangman
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 2013
  • Excessive precipitation, drought, heat waves, strong typhoons and rising sea levels are just some of the common indicators of climate change. In the Philippines, excessive precipitation never failed to devastate and drown the streets of Metro Manila, a highly urbanized and flood-prone area; such problems are expected to occur frequently. Moreover, the water supply of Metro Manila is dependent only to Angat Reservoir. Rainwater harvesting can serve as an alternative source of raw water and it can mitigate the effects of flooding. The harvested rainwater can be used for: potable consumption if filtered and disinfected; and non-potable consumptions (e.g., irrigation, flushing toilets, carwash, gardening, etc.) if used untreated. The rainfall data were gathered from all 5 rainfall stations located in Metro Manila namely: Science Garden, Port Area, Polo, Nangka and Napindan rain gauge stations. To be able to determine the potential volume of rainwater harvested and the potentiality of rainwater harvesting system as an alternate source of raw water; in this study, three different climatic conditions were considered, the dry, median and wet rainfall years. The frequent occurrence of cyclonic events in the Philippines brought significant amount of rainwater that causes flooding in the highly urbanized region of Metro Manila. Based from the results of this study, the utilization of rainwater harvesting system can serve as an alternative source of non-potable water for the community; and could also reduce the amount of surface runoff that could result to extreme flooding.

A Study on the Control and Level Measurement for a Rainwater Tank (우수 저류조 수위측정 및 제어에 대한 연구)

  • Kim, Kee-Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.2 no.4
    • /
    • pp.55-59
    • /
    • 2016
  • In this paper, we propose a system for monitoring and controlling the level of the rainwater tank by installing an underground storage tank as one of ways to increase the utilization rate to solve the water shortage and imbalance. For this purpose, a microprocessor of ATMEL's Atmega 128 is used for the control module, and the sensor capable of measuring the water level uses a float type level sensor which is a kind of tactile sensor. In particular, the level sensor outputs the output in a industry standard dimension, so that the compatibility is improved so as to replace the existing sensor.

Comparison of rainwater utilization rate according to actual capacity-standard capacity of storage tank of rainwater harvesting system (빗물이용시설 저류조 실제용량-기준용량에 따른 빗물이용률 비교)

  • Sim, Inkyeong;Park, Yoonkyung;Kim, Reeho;Park, Jongpyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.418-418
    • /
    • 2022
  • 본 연구에서는 수문학적 물수지 분석을 통한 물수요-공급 시계열 분석을 수행하여 빗물이용률을 산정하였다. 물수지 분석 도구를 개발하였으며, 이를 통해 빗물이용시설 공급충족률(필요수량 대비 빗물이용량), 빗물보장률(전체일수 대비 빗물이용일수), 빗물이용률(빗물이용시서용량 대비 빗물이용가능량)에 대해 분석을 수행하였다. 업무시설, 학교, 체육시설(공원), 공동주택에 대해 수요처별 수요 시나리오를 작성하였으며, 고수요 75%, 중수요 50%, 저수요 25%를 적용하였다. 시나리오별 실제 용량과 기준용량에 따른 빗물이용률을 비교함으로써 현재 설치된 빗물이용시설이 잘 계획되었는지, 과소 계획되었는지 파악할 수 있다. 빗물이용률 분석을 위해 빗물이용시설 유형별 2개소씩 선정하였으며, 빗물이용시설 실제용량 및 기준용량(집수면적(m2)×0.05 적용)에 따른 수요 시나리오별 빗물이용률을 비교하였다. 이와 같이 물수지 분석 도구를 이용하면 다양한 시나리오 적용에 따른 운영 결과를 향후 설치될 빗물이용시설의 설치 이전에 확인하여 최적 운영방안 도출 및 저류조 용량 계획에 참고할 수 있을 것으로 판단된다.

  • PDF