• Title/Summary/Keyword: Rainwater retention

Search Result 26, Processing Time 0.027 seconds

Performance Evaluation of Water Circulation Facilities with Infiltration and Retention Functions (침투 및 저류 기능을 가진 물 순환 시설의 효과 평가)

  • Hong, Jung Sun;Maniquiz-Redillas, Marla C.;Kim, Ree Ho;Lee, Seon Ha;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In 2014, the city of Seoul revised the ordinance regarding water-cycle restoration in the Seoul Metropolitan areas by incorporating the 'Low Impact Development (LID)' policy. The new ordinance plan will utilize 630 mm or almost 45 to 50% of annual rainfall until 2050 by means of providing a rainwater management system consisting of infiltration, retention and vegetation. The LID is believed to be the key to achieving the target requirements, specifically in development projects. This research was performed to evaluate the stormwater runoff and pollutant reduction performance of three different LID facilities (water circulation facilities) including an infiltration inlet, bioretention swale, and permeable pavement constructed in Seoul City. Results show that among the water circulation facilities, the permeable pavement achieved the highest runoff reduction as it was able to entirely capture and infiltrate the runoff to the ground. However, in order to attain a long-term performance it is necessary to manage the accumulated sediment and trapped pollutants in the landscape areas through other water circulation techniques such as through soil erosion control. In terms of pollutant reduction capability, the infiltration inlet performed well since it was applied in highly polluted areas. The bioretention facility integrating the physico-chemical and biological mechanisms of soil, microorganisms and plants were able to also achieve a high runoff and pollutant reduction. The water circulation facilities provided not only benefits for water circulation but also various other benefits such as pollutant reduction, ecological restoration, and aesthetic functions.

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.

The Effect of Low Impact Development Techniques on Urban Runoff (저영향개발기법이 도시 유출에 미치는 영향)

  • Kim, Heesoo;Chung, Gunhui
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.307-316
    • /
    • 2021
  • Due to rapidly increased urbanization, impervious area has been extended and concerns about urban flooding has been increased as well. A lot of effort has been made to restore the urban water circulation. Low Impact Development (LID) technology that consist of retention, infiltration, and evapotranspiration has begun to attract attention to simulate the hydrologic phenomenon before and after development. Many researches on the technique is being actively conducted. In this study, the effect on reducing runoff in urban catchment was analyzed and evaluated by applying LID techniques using SWMM and six scenarios. A SWMM-LID model was built for the Gasan 1 rainwater pumping station basin, and Green Roof and Permeable Pavement were selected as LID techniques to be applied. As a result, the reduction effect of the permeable pavement was larger than green roof. In the future, the results could be used to design a LID facility using the characteristics of the watershed, and other urban water resource factors such as river and groundwater levels that affect each other should be considered, so that the entire system can be considered.

A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor - (학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.5
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

Effect of Organic Fertilizer Ratios on the Growth of Spiraea × bumalda 'Gold Mound' in the Container Green Wall Systems with Rainwater Utilization (빗물활용 벽면녹화 용기 내 유기질비료 배합비에 따른 노랑조팝나무의 생육 반응)

  • Ju, Jin-Hee;Kim, Hya-Ran;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1417-1423
    • /
    • 2011
  • For evaluating the effect of various organic fertilizer ratios on the Spiraea${\times}$bumalda 'Gold Mound' growth, a container green wall system experiment was conducted in a greenhouse at Konkuk university. The experimental planting grounds were prepared with different organic fertilizer ratios ($A_1L_0$, $A_8L_1$, $A_4L_1$ $A_2L_1$ and $A_1L_1$) and with drought tolerance and an ornamental value Spiraea${\times}$bumalda 'Gold Mound' was planted. The change in soil moisture contents, plant height, number of branches, number of dead leafs, number of leaf, number of shoots, length of node, length of leaf, width of leaf, root-collar caliper, chlorophyll contents and survival rate were investigated from April to Jun 2010. 1. The result of soil moisture contents was analyzed with weight unit in the container green wall system during the dry summer season. The soil moisture contents were significantly enhanced in the container green wall system in increasing order as the amount of fertilizer level increased $A_1L_1$ > $A_2L_1$ > $A_4L_1$ > $A_8L_1$ > $A_1L_0$. 2. Compared to the control treatment (amended soil with 100% + organic fertilizer 0%) application, the highest plant growth was observed in the treatment of $A_2L_1$(amended soil with 67% + organic fertilizer 13%) application. However, the differences between the organic fertilizer ratio treatments of $A_1L_1$, $A_4L_1$, $A_8L_1$, and the $A_1L_0$ organic fertilizer application were mostly not significant. 3. The survival rate increased with the increasing application of organic fertilizer, but in the control treatment (amended soil with 100% + organic fertilizer 0%) application all the plants died. Experimental results from the presented study clearly demonstrated that the organic fertilizer improved the survival rate more than the Spiraea${\times}$bumalda 'Gold Mound' growth at different levels of organic fertilizers. This strain can be utilized as a plant growth application in living wall systems during the dry summer season. Therefore, Spiraea${\times}$bumalda 'Gold Mound' is expected to be a highly valuable shrub for the green wall system if it should be considered in integration with stormwater retention or as a soil conditioner for increasing soil water contents in planting ground.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.