• Title/Summary/Keyword: Rainfall depth

Search Result 462, Processing Time 0.025 seconds

A study of Spatial Multi-Criteria Decision Making for optimal flood defense measures considering regional characteristic (지역특성을 고려한 홍수방어대안 제시를 위한 공간 다기준의사결정 기법 적용 방안 연구)

  • Lee, Eunkyung;Ji, Jungwon;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.301-311
    • /
    • 2018
  • Recently, the flood inundation caused by heavy rainfall in urban area is increasing due to global warming. The variability of climate change is described in the IPCC 5th report (2014). The precipitation pattern and hydrological system is varied by climate change. Since the heavy rainfall surpassed the design capacity of the pipeline, it caused great damage in metropolitan cities such as Seoul and Busan. Inundation in urban area is primarily caused by insufficient sewer capacity and surplus overflow of river. Inundation in urban area with concentrated population is more dangerous than rural and mountains areas, because it is accompanied by human casualties as well as socio-economic damage to recover destruction of roads, brides and underground spaces. In addition, various factors such as an increase in impervious area, a short time of concentration to outlet, and a shortage of sewer capacity's lack increase flooding damage. In this study, flood inundation analysis was conducted for vulnerable areas using XP-SWMM. Also, three structural flood prevention measures such as drainage pipeline construction, detention reservoir construction, and flood pumping station construction are applied as flood damage prevention alternatives. The flood data for each alternative were extracted by dividing the basin by grid. The Spatial Compromise Programming are applied using flood assessment criteria, such as maximum inundation depth, inundation time, and construction cost. The purpose of this study is to reflect the preference of alternatives according to geographical condition even in the same watershed and to select flood defense alternative considering regional characteristics.

Determination of Optimum Design Capacity of Bio-retention for Improvement of Urban Water Cycle (도시 물 순환 개선을 위한 생태저류지의 최적설계용량 결정)

  • Lee, Okjeong;Choi, Jeonghyeon;Lee, Jeonghoon;Kim, Sangdan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.745-753
    • /
    • 2017
  • In this study, a design strategy is proposed to restore the distorted urban water cycle to the natural water cycle through the LID facility. This is accomplished by determining the optimal LID facility design capacity through which flow duration curves remain the same before and after urban development. A part of the Noksan National Industrial Complex in Busan was selected as the study area and EPA SWMM was constructed to simulate long-term stormwater for various land use scenarios and LID facility design capacity. In the case that the study area was assumed to be a forest area or an agricultural area before urban development, it was found that it was necessary to allocate 7.3% or 5.5% of the impervious area to the area of the bio-retention in order for the flow duration curve to remain the same as before urban development. As a result of the sensitivity analysis of the bio-retention design capacity according to regional rainfall characteristics, the design capacity of 3.8~5.5% of impervious area is needed for the development of agriculture area. Therefore, it can be seen that the optimum capacity can be significantly different according to regional rainfall characteristics. On the other hand, as a result of analyzing the sensitivity of the design capacity according to the variation of the depth of each layer constituting the bio-retention and the size of contributing catchment area, the sensitivity of the optimal design capacity with respect to the design specifications of the bio-retention and the size of contributing catchment area was not significant.

A study on simplification of SWMM for prime time of urban flood forecasting -a case study of Daerim basin- (도시홍수예보 골든타임확보를 위한 SWMM유출모형 단순화 연구 -대림배수분구를 중심으로-)

  • Lee, Jung-Hwan;Kim, Min-Seok;Yuk, Gi-Moon;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.81-88
    • /
    • 2018
  • The rainfall-runoff model made of sewer networks in the urban area is vast and complex, making it unsuitable for real-time urban flood forecasting. Therefore, the rainfall-runoff model is constructed and simplified using the sewer network of Daerim baisn. The network simplification process was composed of 5 steps based on cumulative drainage area and all parameters of SWMM were calculated using weighted area. Also, in order to estimate the optimal simplification range of the sewage network, runoff and flood analysis was carried out by 5 simplification ranges. As a result, the number of nodes, conduits and the simulation time were constantly reduced to 50~90% according to the simplification ranges. The runoff results of simplified models show the same result before the simplification. In the 2D flood analysis, as the simplification range increases by cumulative drainage area, the number of overflow nodes significantly decreased and the positions were changed, but similar flooding pattern was appeared. However, in the case of more than 6 ha cumulative drainage area, some inundation areas could not be occurred because of deleted nodes from upstream. As a result of comparing flood area and flood depth, it was analyzed that the flood result based on simplification range of 1 ha cumulative drainage area is most similar to the analysis result before simplification. It is expected that this study can be used as reliable data suitable for real-time urban flood forecasting by simplifying sewer network considering SWMM parameters.

자연전위의 효율적 측정을 위한 전극의 잡음요소 분석

  • Song, Seong-Ho;Gwon, Byeong-Du
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.1
    • /
    • pp.9-18
    • /
    • 2002
  • We performed a long-term monitoring of self-potential(SP) using the Cu-CuSO₄non-polarizable electrode and copper-clad electrodes(CCE) in a test site in order to analyze the effects of surrounding environmental noises such as temperature, rainfall and soil moisture content on the electrodes. Analysis of the temperature dependence of the non-polarizable electrodes showed that is temperature coefficient was about +0.5 mV/°Fwhen its end was exposed to atmosphere while it was less than +0.5 mV/℃ when submerged into the subsurface, which reflects that there exists an 8 to 11 hour lag between temperatures at the depth of 15 cm and atmosphere. CCE was independent of atmospheric temperature in subsurface but showed temperature coefficient of 1.0 mV/℃ when exposed to atmosphere. Drifts of 1 to 2 mV recorded with the non-polarizable electrode directly related to the soil moisture content when it was buried in subsurface. Drift with CCE also showed similar trend to the soil moisture content, and 5 mV drift was recorded according to 5% of daily variation. The soil moisture content had strong effects on the measurement with CCE in rainfall since the flow potential is generated on the surface of the electrode.

  • PDF

Nitrogen Leaching and Balance of Soils Grown with Cabbage in Weighing Lysimeter (중량식 라이시미터에서 배추 재배에 따른 질소 용탈과 수지)

  • Lee, Ye Jin;Ok, Jung Hun;Lee, Seul Bi;Sung, Jwa Kyung;Song, Yo Sung;Lee, Deog Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.3
    • /
    • pp.166-171
    • /
    • 2018
  • BACKGROUND: Nitrogen leaching depends on the drainage pattern and nitrate content, and those are influenced by soil hydraulic properties and fertility. The purpose of this study was to confirm how soil texture contributed to leaching and balance of nitrogen, as well as to drainage. METHODS AND RESULTS: This study was performed using undisturbed weighing lysimeters which were piled up with clay loam (Songjung series) and sandy loam (Sanju series) soils in National Institute of Agricultural Science experimental field. Chinese cabbage was cultivated from August 30 to October 31, 2017. The application rates of N, $P_2O_5$, and $K_2O$ were 21.5, 7.8, and $15.0kg\;10a^{-1}$, respectively, and irrigation was supplied at -33 kPa in 30 cm soil depth. Drainage in clay loam was not noticeable, although it was increased by rainfall in early September. By contrast, the trend of drainage in sandy loam was strongly dependent upon rainfall pattern. Owing to different drainage patterns between both soil textures, nitrogen leaching was 5-fold higher in sandy loam than in clay loam. Nitrogen use efficiencies in clay loam and sandy loam were represented as 43% and 52%, respectively. CONCLUSION: The pattern of drainage and nitrogen leaching were greatly depended on clay content in soil. From this study, we carefully suggest that soil texture should be considered as an incidental factor to estimate nitrogen balance.

Application of dual drainage system model for inundation analysis of complex watershed (복합유역의 침수해석을 위한 이중배수체계 유출모형의 적용)

  • Lee, Jaejoon;Kwak, Changjae;Lee, Sungho
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.301-312
    • /
    • 2019
  • The importance of the dual drainage system model has increased as the urban flood damage has increased due to the increase of local storm due to climate change. The dual drainage model is a model for more accurately expressing the phenomena of surface flow and conduit flow. Surface runoff and pipe runoff are analyzed through the respective equations and parameters. And the results are expressed visually in various ways. Therefore, inundation analysis results of dual drainage model are used as important data for urban flood prevention plan. In this study, the applicability of the COBRA model, which can be interpreted by combining the dual drainage system with the natural watershed and the urban watershed, was investigated. And the results were compared with other dual drainage models (XP-SWMM, UFAM) to determine suitability of the results. For the same watershed, the XP-SWMM simulates the flooding characteristics of 3 types of dual drainage system model and the internal flooding characteristics due to the lack of capacity of the conduit. UFAM showed the lowest inundation analysis results compared with the other models according to characteristics of consideration of street inlet. COBRA showed the general result that the flooded area and the maximum flooding depth are proportional to the increase in rainfall. It is considered that the COBRA model is good in terms of the stability of the model considering the characteristics of the model to simulate the effective rainfall according to the soil conditions and the realistic appearance of the flooding due to the surface reservoir.

Development of a new system for measurement of total effluent load of water quality

  • Keiji, Takase;Akira, Ogura
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.221-221
    • /
    • 2015
  • Sustainable use of water resource and conservation of water quality are essential problems in the world. Especially, problems of water quality are serious one for human health as well as ecological system of all creatures on the earth. Recently, the importance of total effluent load as well as the concentrations of pollutant materials has been recognized not only for the conservation of water quality but also for sustainable water use in watersheds. However, the measurement or estimation of total effluent load from non-point source area such as farm lands or forests may be more difficult because both of concentration and discharge of the water are greatly changed depending on various factors especially metrological conditions such as rainfall, while the measurement from a point source area may be easy because the concentration of pollutant materials and amount of discharge water are relatively steady. Therefore, the total effluent load from a non-point source is often estimated by statistical relationships between concentration and discharge, which is called as L-Q equation. However, a lot of work and time are required to collect and analyze water samples and to get the accurate relationship or regressive equation. So, we proposed a new system for direct measurement of total effluent load of water quality from non-point source areas to solve the problem. In this system, the overflow depth at a hydraulic weir is measured with a pressure gage every hourly interval to calculate the amount of hourly discharge at first. Then, the operating time of a small electric pump to collect an amount of water which is proportional to the discharge is calculated to intake the water into a storage tank. The stored water is taken out a few days later in a case of storm event or several weeks later in a case of non-rainfall event and the concentrations of water quality such as total nitrogen and phosphorous are analyzed in a laboratory. Finally, total load of the water quality can be calculated by multiplying the concentration by the total volume of discharge. The system was installed in a small experimental forestry watershed to check the performance and know the total load of water quality from the forest. It was found that the system to collect a proportional amount of water to actual discharge operated perfectly and a total load of water quality was analyzed accurately. As the result, it was expected that the system will be very available to know the total load from a non-point source area.

  • PDF

An Analysis of the Application Effect of LID Technology in Urban Inundation Using Two-Dimensional Model (2차원 모델을 이용한 도시침수지역에서의 LID기법 적용효과 분석)

  • Minjin Jung;Juho Kim;Changdeok Jang;Kyewon Jun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.13-22
    • /
    • 2023
  • The importance of preemptive flood preparation is growing as the importance of preparing for climate change increases due to record heavy rains in the Seoul metropolitan area in August 2022. Although it is responding to flood control through reservoirs and sediment sites, the government is preparing excellent spill reduction measures through a preliminary consultation system for Low Impact Development (LID). In this study, the depth of flooding was simulated when LID technologies were applied to the Sillim 2-drain region in Dorimcheon Stream basin, an urban stream, using XP-SWMM, a two-dimensional model. In addition, the analysis and applicability of the effect of reducing rainfall runoff for the largest rainfall in a day were reviewed, and it was judged to be effective as a method of reducing flooding in urban areas. Although there is a limitation in which the reduction effect is overestimated, it is thought that the LID technologies can be a significant countermeasure as a countermeasure for small-scale flooded areas where some flooding occurs after structural flooding measures are established.

Comparing Methods for Determining Flood Protection Elevation in Urban Built-up Areas (도시지역 방어침수위 설정방법 비교분석)

  • Lee, Yang Jae;Shin, Sang Young;Lee, Chang Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.271-281
    • /
    • 2008
  • To determine the flood protection elevation (FPE) in urban built-up areas, this study examines four possible methods: using the highest flood elevation in the past, extending base flood elevations of nearby watercourse to inland, and two simulation methods of inland flood under the same rainfall used in the watercourse planning nearby. According to the case study of the Jang-An Drainage Area, Seoul, the highest flood elevation in the past and simulation results of inland flood under the same rainfall in the watercourse planning nearby tend to get similar results, while extending base flood elevations of nearby watercourse to inland shows much higher elevations than other results. Meanwhile, cost-benefit analysis, when regulating residential/commercial uses below the FPE by each of four methods, suggest that planners need to consider carefully the economic feasibility of FPE used to choose appropriate methods.

Monitoring the Alternative Habitat of Kaloula Borealis and Analysis on Meteorological Factors in Pyeongtaek (평택지역의 맹꽁이 대체서식지 모니터링 및 기상요인 분석)

  • Min-Ho Choi;Yang-Seop Bae
    • Journal of Life Science
    • /
    • v.34 no.4
    • /
    • pp.264-270
    • /
    • 2024
  • This study is conducted to analyze environmental factors that affect the ecology of boreal digging frog and use them as basic data for selecting (or creating) suitability of alternative habitats for survival and monitoring method from 2020 to 2022 after boreal digging frog were relocated to the alternative habitats in 2019. Analyzing the environment of the alternative habitats showed that the criteria suited the followings: distance from wetlands, grasslands and rivers was within 5 m, the low-rise grassland was 6,000 m2, soft soil was at a depth of ≥20 cm, and the area of permanent wetlands was 5,000 m2 wide. As a result of the correlation analysis between meteorological factors and population (n) and breeding, there was a significant correlation between rainfalls and breeding (p<0.01). During the monitoring, it was confirmed that the SVL (Snout-Vent Length) and BM (Body Mass) of the translocated population were maintained (p>0.05), and it was found that the proximity of the habitat and spawning pond, securing food space (grasslands), soil quality, and wetlands could function as an alternative habitat if conditions were met. As a result of analyzing the meteorological factors affecting the population of boreal digging frog, the SVL had a statistical impact on the minimum temperature, maximum temperature, relative humidity, and the rainfall (p<0.05). In the case of breeding, rainfall was found to be affected (p<0.01), and the population was statistically affected by the average temperature, minimum temperature, and relative humidity (p<0.05).