• Title/Summary/Keyword: Rain removal

Search Result 66, Processing Time 0.024 seconds

Study on Chemical Removal of Nitric Oxide (NO) as a Main Cause of Fine Dust (Air Pollution) and Acid Rain

  • Seo, Hyeon Jin;Jeong, Rak Hyun;Boo, Jang-Heon;Song, Jimin;Boo, Jin-Hyo
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.218-222
    • /
    • 2017
  • This study was conducted to remove $NO_x$, which is the main cause of fine dust and air pollution as well as acid rain. $NO_x$ was tested using 3% NO (diluted in He) as a simulated gas. Experiments were sequentially carried out by oxidizing NO to $NO_2$ and absorbing $NO_2$. Especially, we focused on the changes of NO oxidation according to both oxidant ($NaClO_2$) concentration change (1~10 M) and oxidant pH change (pH = 1~5) by adding HCl. In addition, we tried to suggest a method to improve $NO_2$ absorption by conducting $NO_2$ reduction reaction with reducing agent (NaOH) concentration (40~60%). It was found that NO removal efficiency increased as both concentration of oxidant and flow rate of NO gas increased, and NO decreased more effectively as the pH of hydrochloric acid added to the oxidant was lower. The $NO_2$ adsorption was also better with increasing NaOH concentration, but the NO removal efficiency was ~20% lower than that of the selective NO reduction. Indeed, this experimental method is expected to be a new method that can be applied to the capture and removal of fine dust caused by air pollution because it is a method that can easily remove NO gas by a simple device without expensive giant equipment.

Effective adsorption of lead and copper from aqueous solution by samaneasaman and banana stem

  • Harish, Narayana;Janardhan, Prashanth;Sangami, Sanjeev
    • Advances in environmental research
    • /
    • v.7 no.3
    • /
    • pp.225-237
    • /
    • 2018
  • The sorption of metal ions with low-cost adsorbents plays an important role in sustainable development. In the present study, the efficacy of sugarcane bagasse, rain tree fruits (samaneasaman), banana stem and their mixtures, used as bio-sorbents, in the removal of Cu(II) and Pb(II) ions from aqueous solution is evaluated. Batch studies are conducted, and residual ions were measured using Inductively Coupled Plasma (ICP)-atomic spectrometer. Effect of pH, initial metal ion concentration, reaction time and adsorbent dosage are studied. The Pb(II) removal efficiency was observed to be 97.88%, 98.60% and 91.74% for rain tree fruits, banana stem and a mixture of adsorbents respectively. The highest Cu(II) ion removal was observed for sugarcane bagasse sorbent with an efficiency of 82.10% with a pH of 4.5 and a reaction time of 90 min. Finally, desorption studies were carried out to study the leaching potential of adsorbent, and it was found that the adsorbent is stable in water than the other leaching agents such as HCl, ammonium acetate, Sodium EDTA. Hence, these adsorbents can be effectively used for the removal of these heavy metals.

Permeable Coastal Pavement Structure for Shore Protection and Removal of Non-point Source Pollutants (연안재해 방지 및 비점오염원 유출저감을 위한 투수블록의 특성 연구)

  • Choi, Yun-Shik;Kim, Jong-Yeong;Han, Sangsoo;Kwon, Soonchul
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.597-606
    • /
    • 2019
  • Due to climate change, coastal areas are being flooded with torrential rain, typhoons, and tsunamis. In addition, non-point source pollutants (NPSs) that accumulated on the ground, streets, and buildings during the dry season are washed off by rain and stormwater runoff, which adds to the damage associated with environmental pollution, e.g., pollution that makes its way into the ocean. Recently, low impact development (LID) has been considered as a means of controlling water circulation and NPSs. In the coastal area, permeable blocks have been constructed mainly to reduce the flood damage caused by waves. Some important design factors that must be considered to ensure long-term performance are the permeability coefficient, clogging, and the efficiency of the removal of total suspended solids (TSS), but currently there are no standardized design criteria or testing techniques that are used worldwide. Herein, we analyzed the permeability coefficient and the TSS removal efficiency tendency according to the permeability area ratio with an easily-detachable, permeable block filled with calcinated yellow soils as the filter media. Our lab-scale tests indicated that, when the permeability area ratio was 25%, the reduction of the permeability coefficient after clogged was 11%, which was a significant decrease compared to other cases. Permeability persistence increased when the permeability area ratio increased from 50% to 75%. The TSS removal efficiency decreased as the permeability area ratio increased. Our pilot-scale test indicated that the TSS removal efficiency was more than 80% higher in all cases. We also found that the permeability persistence was excellent as the permeability area ratio increased, and, in actual construction, it is effective to set 5.3% of the total area as permeable area in terms of permeability and economic feasibility.

Assessment of Performances of Low Impact Development (LID) Facilities with Vegetation (식생이 조성된 LID 시설의 효율 평가)

  • Hong, Jung Sun;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.100-109
    • /
    • 2016
  • Low impact development (LID) facilities are established for the purpose of restoring the natural hydrologic cycle as well as the removal of pollutants from stormwater runoff. Improved efficiency of LID facilities can be obtained through the optimized interaction of their major components (i.e., plant, soil, filter media, microorganisms, etc.). Therefore, this study was performed to evaluate the performances of LID facilities in terms of runoff and pollutant reduction and also to provide an optimal maintenance method. The monitoring was conducted on four LID technologies (e.g., bioretention, small wetlands, rain garden and tree box filter). The optimal SA/CA (facility surface area / catchment area) ratio for runoff reduction greater than 40% is determined to be 1 - 5%. Since runoff reduction affects the pollutant removal efficiency in LID facilities, SA/CA ratio is derived as an important factor in designing LID facilities. The LID facilities that are found to be effective in reducing stormwater runoff are in the following order: rain garden > tree box filter > bioretention> small wetland. Meanwhile, in terms of removal of particulate matter (TSS), the effectiveness of the facilities are in the following order: rain garden > tree box filter > small wetland > bioretention; rain gardens > tree box filter > bioretention > small wetland were determined for the removal of organic matter (COD, TOC), nutrients (TN, TP) and heavy metals (Cu, Pb, Cd, Zn). These results can be used as an important material for the design of LID facilities in runoff volume and pollutant reduction.

Transport of nonpoint source pollutants and stormwater runoff in a hybrid rain garden system (하이브리드 빗물정원 시스템에서의 비점오염물질 및 강우유출수 이송 특성)

  • Flores, Precious Eureka D.;Maniquiz-Redillas, Marla C.;Geronimo, Franz Kevin F.;Alihan, Jawara Christian P.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.481-487
    • /
    • 2016
  • In this research, a pilot scale hybrid rain garden system was developed in order to investigate the efficiency in the different components of the hybrid rain garden system and at the same time evaluate the initial efficiency of the system in treating urban stormwater runoff prior to its actual use in the field. Experimental runs were conducted using synthetic runoff having target concentrations similar to that of the typical runoff characteristics found in different countries and in Korea. With the employment of the hybrid rain garden system, hydrologic improvement was observed as the system demonstrates an approximately 95% reduction in the influent runoff volume with 80% retained in the system, and 15% recharged to groundwater. The reduction was contributed by the retention capabilities of ST and infiltration capabilities in PB and IT. With the combined mechanisms such as filtration-infiltration, biological uptake from plants and soil and phytoremediation that are incorporated in PB and IT, the system effectively reduces the amount of pollutant concentration wherein the initial mean removal efficiency for TSS is 87%, while an approximate mean removal efficiency of 76%, 46% and 56% was observed in terms of organics, nutrients and heavy metal, respectively. With these findings, the research helps in the further improvement, innovation and optimization of rain garden systems and other facilities as well.

Development of Pilot-Scale Scrubber for Simultaneous Removal of $SO_2/NO$

  • Jung, Seung-Ho;Jeong, Gwi-Taek;Lee, Gwang-Yeon;Park, Don-Hee;Cha, Jin-Myeong
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.468-474
    • /
    • 2005
  • SOx and NOx are known major precursors of acid rain and thus the abatement of their emissions is a major target in air pollution control. To obtain basic data on the removal process of simultaneous $SO_2/NO$, the optimal reaction condition and the composition of reaction solution for simultaneous removal of $SO_2/NO$, ware investigated using a bubble column reactor. Pilot scrubber was consisted of scrubber, filter and control box. Dust removal rate was 83, 92, and 97% with catalyst flux of 0.5, 0.8, 1.5 L/min, respectively Average dust removal efficiency with a kind of nozzle was about 94 and 90% in STS FF6.5 (5/8in.) and 14 of P.P W(1.0in.), respectively Dust and $SO_2$ were removed more than 98-96% regardless of reactor number. In the case of NO gas, removal yield of 83.3% was achieved after 48 hours in 1 stage, also removal yield of 95.7% was reached in 2 stages. In tile case of application of STS (5/8 in.) and P.P (1.0 in.) as used fill packing, removal efficiency was reached higher than 98% without related to of kind of fill packing.

  • PDF

NOx Removal Characteristics Using Radical In A Diesel Engine (Radical을 이용한 디젤 엔진의 NOx 제거 특성)

  • Jeon, J.H.;Choi, S.H.;Jeon, C.H.;Chang, Y.J.;Lee, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.715-719
    • /
    • 2000
  • It is reported that we are facing the serious environment pollution difficulties such as acid rain, green house effects, etc. The gaseous matter CO, NOx, SOx, VOCs which are regarded as main factors for these current pollutions are mainly emitted from power plants and vehicles. Therefore several leading countries are regulating the related laws strictly, especially exhaust emissions from a Diesel engine without an after treatment device. The Objective of this study is to find out NOx removal characteristics focused on emissions of a Diesel engine using radical at each engine speed and load. It is generated from outer air and put into a mixing chamber in the end of exhaust line. In addition, the optimum temperature condition to activate reaction by radical is experimentally carried out. Concentration of exhaust emissions is analyzed from the gas anlayzer(KaneMay) and FTIR to estimate by-products.

  • PDF

A Study on Treatment of CSOs by Vortex Separator and Continuous Fiber-Filter System (Vortex separator와 연속식 섬유사여과를 이용한 CSOs 처리연구)

  • Lee, Bum-Joon;Na, Ji-Hoon;Kim, Jin-Sung;Joo, Jae-Young;Bae, Yoon-Sun;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.443-451
    • /
    • 2010
  • This study was conducted to confirm the CSOs characteristics, and to estimate treatment efficiency of CSO treatment process. Flowrate was average $53,500m^3$/d, maximum $58,100m^3$/d during dry season, but after rain-fall, the flowrate was increased more than twice that of the dry season. And, water pollution concentrations, such as $COD_{Cr}$, SS, $BOD_5$, TN and TP of after rain-fall, were also increased. Thus, for more efficient treatment of pollutants during rainy season, The vortex separator and continuous fiber filter devices were used. From the results on particle range, removal efficiency of particle was 99.7% at the particle size range of $40{\sim}100{\mu}m$ but decreased as 55-80% at the below $40{\mu}m$. The removal efficiencies of $COD_{Cr}$, SS, TN and TP were approx. 70, 60, 70 and 50, respectively during the dry season and approx. 50, 50, 8 and 18% during the rainy season. Also, when compared with the primary sediment basin, $COD_{Cr}$, SS, TN and TP removal efficiencies were high. especially, at the case of TN and TP, TN was more removed than TP because of higher conversion factor value. But we needed more study for the injection of a coagulants to get more stable treatment efficiency for soluble pollutants. Consequently, This process can be used for CSOs treatment as well as replace the primary sedimentation basin during the dry season.

Removal Characteristics of Soot and NO by Nonthermal Plasma and Radical in a Diesel Engine (비열플라즈마와 라디칼을 이용한 디젤엔진의 매연 및 NO 제거 특성)

  • Jang, Yeong-Jun;Choe, Seung-Hwan;Kim, Gyu-Bo;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.547-554
    • /
    • 2002
  • We are facing the serious environmental pollution difficulties such as acid rain, green house effects, etc. The gaseous matter NOx, SOx, VOCs which are regarded as main factors for these current pollutions are mainly emitted from power plants and vehicles. Therefore several leading countries are regulating the emissions strictly, especially the exhaust emissions from a Diesel engine without an aftertreatment device. The objective of this study is to find out soot and NO removal characteristics focused on the emissions of a Diesel engine by using nonthermal plasma for each engine speeds and loads. Electrostatic precipitator(wire-to-plate type reactor) is used for soot removal. Radicals generated from outer air and put into a mixing chamber in the end of exhaust line are used for NO removal. Concentration of exhaust emissions is analyzed from the gas analyzer(KaneMay) and FTIR to estimate by-products.

Target Detection for Marine Radars Using a Data Matrix Bank Filter

  • Jang, Moon Kwang;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.151-157
    • /
    • 2013
  • Marine radars are affected by sea and rain clutters, which can make target discrimination difficult. The clutter standard deviation and improvement factor are applied using multiple parameters-moving speed of radar, antenna speed, angle, etc. When a radar signal is processed, a Data Matrix Bank (DMB) filter can be applied to remove sea clutters. This filter allows detection of a target, and since it is not affected by changes in adjacent clutters resulting from a multi- target signal, sea state clutters can be removed. In this paper, we study the level for clutter removal and the method for target detection. In addition, we design a signal processing algorithm for marine radars, analyze the performance of the DMB filter algorithm, and provide a DMB filter algorithm design. We also perform a DMB filter algorithm analysis and simulation, and then apply this to the DMB filter and cell-average constant false alarm rate design to show comparative results.