• Title/Summary/Keyword: Railway station of square

Search Result 7, Processing Time 0.027 seconds

A study on the characteristics of layout patterns of railway station square according to the characteristics of railway station (철도역 개발특성을 통한 역광장 배치유형 계획특성 연구)

  • Yang, Seung-Hee;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.571-581
    • /
    • 2016
  • This study focused on the characteristics of railway station squares according to layout patterns, which provide transit and links between the station and town. The results were as follows: (1) The analysis examined the characteristics of the railway station to the location and types the proportion: civic center type (59.3%) and ground station (43.7%), and upper railroad station (40.6%). The spatial configurations of the railway station square were obtained: Traffic space and Environment space. (2) The railway station square space configurations was classified as 4 main layout types: Turn place type (PC), Circulation type (PI), Stop place type (PS-1), and Stop place type (PS-2) (3) The average size for each type of railway station square layout patterns of the Location was larger than the civic center type ($16,882.3m^2$) to suburbs type ($37,698.9m^2$). The average form for each type of a railway station square layout patterns of the Location was the civic center type (1.00:0.73) and suburb type (1.00:0.37).

A Study on the Improvement Plan of Railway Station & Surrounding Area for Regional Refurbishment (Focused on Dongincheon Railway Station) (지역활성화를 위한 철도 및 역세권 정비방안 연구(인천광역시 동인천역을 중심으로))

  • Shin, Ye-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.412-418
    • /
    • 2012
  • This paper suggests some strategies for the regional regeneration of Dongincheon Railway station and surrounding area. One is the reduction of the regional unbalance in those divided into two parts, the other is multi-dimentional plan through the efficient land-use on the side area of railway. For these regional refurbishment Plan, organizing the integrated transit system for the passenger's convenience, connecting existing commercial area and existing northen station square, modernization and improvement of environment are suggested.

Development of Selection Model of Subway Station Influence Area (SIA) in Seoul City using Chi-square Automatic Interaction Detection (CHAID) (CHAID분석을 이용한 서울시 지하철 역세권 지가 영향모형 개발)

  • Choi, Yu-Ran;Kim, Tae-Ho;Park, Jung-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.504-512
    • /
    • 2008
  • In general, based on criteria of subway law, radius 500m from subway station is defined as SIA (Subway Station Influence Area). Therefore, in this paper, selection models of SIA are developed to identify appropriate SIA for specific legions in Seoul metropolitan city based on CHAID analysis. As a result, following outputs are obtained; (1) walking distance from subway station is the most influential factor to define SIA (2) SIAs vary with regions (i. e. Gangnam area: 767m, Gangbuk area: 452m), and (3) walking distance from subway station is influential to land price of SIA. In addition, in Gangnam, the structure of land price of the closest section has a polynomial trend curve rather than linear compared in comparison with other sections. Therefore, it is desirable for current definition of SIA (radius 500m from subway station) to be redefined to reflect characteristics of land use and walking distance according to each region respectively.

Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires (철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 수치연구)

  • Jang, Won-Cheol;Kim, Dong-Woon;Ryou, Hong-Sun;Lee, Seong-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2130-2138
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading characteristics in railway tunnels with the rescue stations. Experiments were carried out for n-heptane pool fires with a square length 4 cm at different fire locations, and the heat release rates (HRR) were obtained by the measurement of burning rates. In addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

  • PDF

Calibration of Timetable Parameters for Rail-Guided Systems

  • Zhao, Weiting;Martin, Ullrich;Cui, Yong;Kosters, Maureen
    • International Journal of Railway
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In order to achieve a comprehensive utilization of railway networks, it is necessary to accurately assess the timetable indicators that effect the train operation. This paper describes the parameter calibration for two timetable indicators: scheduled running time and scheduled dwell time. For the scheduled running time, an existing model is employed and the single timetable parameter (percentage of minimum running time) in that model is optimized. For the scheduled dwell time, two intrinsic characteristics: the significance of stations and the average headway at each station are proposed firstly to form a new model, and the corresponding timetable parameters (the weight of the significance and the weight of the average headway) are calibrated subsequently. The Floyd Algorithm is used to obtain the connectivity among stations, which represents the significance of the stations. A case study is conducted in a light rail transportation system with 17 underground stations. The results of this research show that the optimal value of the scheduled running time parameter can be automatically determined, and the proposed model for the scheduled dwell time works well with a high coefficient of determination and low relative root mean square error through the leave-one-out validation.

Analysis of Cooling Air Current and Efficiency of Air Conditioning in the Underground Subway Station with Screen-Door Opening and Closing (도시철도 역사 스크린 도어 개폐에 따른 냉방 기류 해석 및 효율 비교 분석)

  • Jang, Yong-Jun;Ryu, Ji-Min;Jung, Ho-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Numerical prediction methods were applied to investigate the turbulent air currents and air-conditioning efficiency in an underground subway station, and the results compared to experimental data. The Shin-gumho Station($8^{th}$ floor underground and 43.6m in depth) in Seoul was selected for the analysis. The entire station was covered for simulation and the ventilation mode was ordinary. The ventilation diffusers were modeled as 95 square shapes of $0.6m{\times}0.6m$ in the lobby and as 222 square shapes in the platform. Cooling air of $47,316m^3/h$ was supplied and the returned air of $33,980m^3/h$ is exhausted in the lobby and the cooling air of $33,968m^3/h$ is supplied and the returned air of $76,190m^3/h$ was exhausted in the platform which is the same as the experimental data. The cases of the screen-door-closed and open were respectively investigated. A total of 7.5million grids were generated and the whole domain divided into 22 blocks for MPI efficiency of calculation. Large eddy simulation (LES) was applied to solve the momentum and energy equation.

Characteristics of Smoke Propagation in Railway Tunnels with Rescue Station (구난역을 갖는 철도 터널 내부의 연기거동 특성)

  • Jang, Won-Cheol;Kim, Dong-Woon;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.13-18
    • /
    • 2009
  • The main objective of the present study is to investigate smoke propagation in railway tunnels with rescue stations. In particular, based on measurement of HRR (heat release rate) for pool fires formed at different locations, the influence of fire source location on smoke behavior is examined. The fuel is n-heptane and pool fires are generated with a square length 4cm. With the use of MVHS (Modified Volumetric Heat Source) model for fire source, extensive numerical simulations are performed by using the commercial code FLUENT (Ver.6.3) Predicted smoke temperatures and smoke propagation are discussed. From numerical predictions, it is found that ventilation systems may be necessary in the railway tunnels because the smoke moves along the tunnel, and consequently it enters the non-accident tunnel. It is also confirmed that the cross-passage and fire protection wall systems contribute to control the smoke.