2차 보간법을 이용한 전기철도 급전계통의 고장점 산출 기법에 관한 연구 (A Study on Estimation Technique for Fault Location using Quadratic Interpolation in a Parallel Feeding AC Traction System)

  • 민명환;안태풍;권성일;정호성
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.599-604
    • /
    • 2017
  • Nowadays reactance method is being used as a technique for fault location in parallel feeding AC traction power system. However, implementation of this method requires a large number of field tests(ground fault) which is a huge burden on the operators. This paper presents a new estimation technique using quadratic interpolation to reduce number of times for field test and improves the accuracy of fault location. To verify a new technique, we solve AT feeding circuit and model it using PSCAD/EMTDC. Finally this paper conducts a comparative analysis of usefulness between a new technique and real field data.

경량전철 추진용 영구자석 동기전동기의 고정자 철손 저감 연구 (A study on the Reduction of the Stator iron loss on Permanent Magnet Synchronous Motor for Light Railway Transit Propulsion System)

  • 박찬배;이형우;이병송
    • 한국철도학회논문집
    • /
    • 제15권4호
    • /
    • pp.376-380
    • /
    • 2012
  • IPMSM의 구동 중에 발생되는 철손은 코어 재료 특성에 의해 크게 좌우되며, 일반적으로 회전형 전동기에서는 모든 자속의 흐름 방향으로 자기적 특성이 동일한 무방향성 전기강판이 코어 재료로 사용된다. 무방향성 전기강판과 비교하여 방향성 전기강판은 자속의 흐름 방향으로의 자기적 특성이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 IPMSM의 철손을 저감시키기 위하여 코어 재료로써 무방향성 전기강판과 방향성 전기강판을 동시에 사용하는 구조를 제안하였다. IPMSM의 고정자에 자속 흐름의 방향으로 가공된 방향성 전기강판을 이용한 분할 티스 구조를 적용함으로써 기존의 110kW급 IPMSM과 비교하여 거의 40% 정도의 철손 저감 효과를 얻을 수 있었다.

다단자망 알고리즘을 이용한 급전시스템의 무효전력 보상 모델링 및 시뮬레이션 (Modeling and Simulation Reactive Power Compensator using Multi-port Network Algorithm in Electrified Railway)

  • 김주락
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.883-887
    • /
    • 2016
  • The power supply system in Korean electrified railway has adopted AT feeding. If a fault occurs in some substation for any reason, the vicinity substation must feed electric power on the outage substation through catenary. So, the feeding distance grows twice of the normal state at extended feeding condition. If substation's feeding distance is longer than normal condition, the catenary impedance and train to supply electric power from the substation. Therefore, the severe voltage drop can occur and power supply shall be not allowed. This paper presents the model of compensator against voltage drop using multi-port network algorithm. Whole traction power supply system can be analyzed with this model. Computer simulation including this model is performed based on real train schedule and increased schedule in case studies.

직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰 (An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System)

  • 이재봉;정노건;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

직류급전계통에서 레일전위상승제한장치의 동작제어기법 (A Control Technique for the Rail Potential Limit Device in DC Feeding System)

  • 민명환;정호성;박영;창상훈;신명철
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.485-490
    • /
    • 2012
  • Nowadays, in metropolitan railroad, DC feeding system is being generally applied. In order to reduce damage of electro-chemical corrosion caused by stray current and leakage current, in DC feeding system, rail is used as negative-polarity return conductor for traction load current. However, it has problem of rail potential increase and there are no adequate measures to prevent it in domestic. The rise of rail potential leads to damage for human and equipments. To solve the problems, this paper presents fundamental theory and related standards about rail potential increase. And then, we analyzed field testing data and simulated a variety of operations by using PSCAD/EMTDC as an analysis program of power system. In addition, this paper suggests rail potential limit device and addresses how to the device. To verify the effect, simulation of DC feeding system before and after the application of the device is carried out in various cases.

고속철도 전차선로 드로퍼 클램프 내구성 기준 정립에 관한 연구 (A Study on Durability Standard Specification of the Dropper Clamp of Catenary for High Speed Railway)

  • 오완식;양인동;박병곤;홍석진;김성철
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1431-1436
    • /
    • 2017
  • The high-speed railway of catenary system, supplies a stable electric power supply to the train by satisfying the special conditions between pantograph and trolley wire, which operates more than 250km/h mutually sliding and feeding electric lines. According to Korean Railway Standard KRS PW 0026-13 (R), the standard for the grip strength of the dropper clamp in conventional line is established, but the high-speed railway line is not yet. When the grip strength of the dropper clamp is detached from the catenary line of the high-speed railway line, various problems may occur, such as damage to the pantograph due to the collision and arcing. In this paper, it is expected to be used as a basic data for establishing the durability criteria of the high-speed railway dropper clamp by verifying the dropper clamp on the Gyeong-bu and Honam high-speed line.

급전시스템 파라미터의 통신유도영향분석 (Parameter Analysis on the Telecommunication Induction in Electric Railway Feeding System)

  • 한문섭;이장무;권삼영;김용규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1248-1250
    • /
    • 2001
  • 전기철도에서의 급전시스템은 레일을 귀선으로 사용하는 단상급전시스템을 사용하고 있다. 이에 따라 레일로부터 대지로의 누설에 의해 상당한 누설전류가 대지로 흐르게 된다. 대지로 흐르는 이 누설전류는 전자유도에 의해 선로 주변에 설치된 통신 케이블 또는 장치에 영향을 주게 된다. 더욱이 전기차의 견인시스템은 견인전동기를 제어하는데 있어서 스위칭 소자의 개폐에 의한 고조파 전류를 발생하고 있어 대지누설전류에 고조파 전류가 포함되어 흐른다. 본 연구에서는 전기철도 급전시스템에서 통신유도원인 대지누설전류에 따른 고려되어야 할 급전시스템 설계 파라미터를 시뮬레이션을 통하여 검증하였으며, 이 결과가 향후 급전시스템 설계시 기본적인 지침이 되어야 할 것이다.

  • PDF

고속철도 급전계통 고조파 저감설비 설치에 따른 저감효과 검토 (Investigation of Reduction Effect according to installation of Harmonic Diminution Equipments at Feeding System of High Speed Railway)

  • 이장무;한문섭;박현준;신창기;이인재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1388-1390
    • /
    • 2004
  • 경부고속철도 급전구간을 운행하는 KTX 고속열차는 싸이리스터 위상제어방식을 사용하는 대용량의 집중부하로 고속열차가 운행될 때 차량에서 발생되는 많은 고조파 전류가 철도급전계통으로 유입된다. 이러한 고조파 전류가 한국전력계통으로 유입되면 한전계통의 전압왜형율을 증가시켜 전력품질을 저하시키게 된다. 이에따라 모든 고속철도 변전소에는 고조파 전류 저감을 위한 필터설비가 설치되어 있다. 필터설비 설치에 따라 고속철도 급전계통으로 유입되는 고조파 전류와 전압왜형율 측정결과로 고조파 저감효과를 보인다.

  • PDF

직류전기철도에서 전식방지 시스템에 대한 시뮬레이션 분석 (A Simulation Analysis on Electrolytic Corrosion Protection System in DC Feeding System)

  • 민명환;정호성;박영;김형철;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2188-2189
    • /
    • 2011
  • 최근 직류철도에서는 누설전류로 인한 철도 자체 시설물 및 인근 지하매설물의 전식 피해 문제가 대두되고 있다. 본 논문에서는 전식에 대한 이론과 기존의 전식방지 대책인 선택배류법에 대해 제시하고, 배류기가 적용된 직류철도시스템을 모델링하였다. 시뮬레이션을 통해 배류법적용에 대한 유용성에 대해 연구하였다.

  • PDF

직류급전계통의 회생용 인버터 실용화 적용 (Application of regenerative inverter on DC feeding)

  • 한문섭;장동욱;신효범;김성태;김민수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2200-2201
    • /
    • 2011
  • DC railway systems have been adopted in the urban rail train. When EMU decelerates using electric breaking, regenerative power occurs. extra power is forcibly wasted by resisterIf DC transit system has inverter for reusing regenerative power, energy efficiency in DC transit system will be increased. in this paper present developed regenerative power inverter and its field test result.