• Title/Summary/Keyword: Radon management

Search Result 41, Processing Time 0.025 seconds

International Trends for Radionuclides Management in Drinking water (선진 외국에서의 먹는물 중 방사성물질 관리동향)

  • Park, Sun-Ku;Son, Ji-Hwan
    • Journal of Environmental Policy
    • /
    • v.5 no.2
    • /
    • pp.49-67
    • /
    • 2006
  • The radionuclides in drinking water have been regulated in many countries. In USA, the regulation has been revised for over 30 years since radionuclides have been regulated under Safe Drinking Water Act(SDWA) from 1974. Today, USEPA is finalizing maximum contaminant level goal(MCLG) of zero for radionuclides, maximum contaminant level(MCL) and alternative maximum contaminant level(AMCL) of 300pCi/L and 4,000pCi/L for radon respectively, MCLs of $30{\mu}g/L$ for uranium, and MCLs of 5pCi/L for combined radium 226 and 228. In Canada, Maximum Acceptable Concentration(MAC) value for uranium is $20{\mu}g/L$. WHO revised the guideline value of uranium and radon to $15{\mu}g/L$ and 100Bq/L in september 2004, respectively. On this survey, it has been found that international regulations for radionuclides in drinking water have been established and improved steadily on the knowledge basis from the past decades' studies.

  • PDF

A Study on Risk Communication and Risk Perception in Environmental Problems (환경문제의 위해도 인식과 위해도 홍보 프로그램의 효과분석 -라돈과 다이옥신을 중심으로-)

  • 김진용;신동천;박성은;임영욱;황만식
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.315-324
    • /
    • 2002
  • Risk communication can be defined as the exchange of information about the nature, magnitude, significance, acceptability, and management of risk. The effect of risk communication on the perception and knowledge towards risk of environmental pollutants and it's related factors were investigated in this study. To investigate perception and knowledge of students and teachers towards risk of environmental pollutants, we conducted the survey using self-administrated questionnaire. The subjects were 574 for the first survey and 465 for the seconds survey from May to June, 2000. The main methods of transmission used in this study- through video tape, visual materials, question and answer, and participation in measuring pollutants - were not a one - way street. But an interactive process where information and opinions were exchanged among individuals, groups, and institutions. Environmental pollutants measured with participation of study subjects was Radon in the class room. The concentration of Radon was measured using E -PERM Device by installing it at each site for about 5 days. Subjects showed much interest in environmental pollution. Also, more than 98% of total subjects were perceived as Korea is seriously contaminated at present. By risk communication activity, risk perception of all subjects about Radon was increased, on the other hand, risk perception of Dioxin was decreased except for elementary student. Moreover, knowledge of all subjects about environmental risk was significantly increased (p =0.0001) and effort of reducing environmental pollution was more increased (p<0.05). There is need to further develop, refine, and integrate these approaches environmental risk communication study, there is an even more pressing need to accelerate the diffusion of environmental risk communication practice into government and organizations.

Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul (서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구)

  • Jeon, Jea-Sik;Kim, Mi-Hyung;Lee, Ju-Yeol;Jeon, Myung-Jin;Ryu, In-Cheol;Park, Duck-Shin;Choi, Han-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.

Occupational and Environmental Safety Issues in South Korea and Their Implications for Health Experts (국내 주요 직업병 및 생활제품 위해 사건과 전문가의 역할)

  • Ahn, Jong-Ju
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • The industrial development and socioeconomic structures of a society are inextricably linked to occupational accidents and diseases. Since the 1970s, a series of major occupational diseases have occurred in South Korea, such as mercury poisoning in Munsong-myeon, carbon disulfide poisoning at Wonjin Rayon, and leukemia at Samsung Electronics. These incidents have caused us to take a critical look at the level of worker safety and health management within companies and the government. These serve as symbolic and representational events. Doctors, lawyers, and labor activists concerned about employee safety and lives came together for years to struggle with the government and industry in order to determine what caused the diseases and to obtain compensation for victims. They finally achieved recognition for occupational diseases and recompense for losses. It is difficult to find similar cases to the baby powder asbestos talc cases and the radon bed case internationally, or there is no case where such a large number of consumers have been potentially harmed. It is also difficult to prove that the damage took place due to the victims' diverse geographic locations and ages, as well as the disease's long incubation period. Based on this premise, businesses and the government have been apathetic in acknowledging these diseases and compensating for damages, with few practical outcomes. Furthermore, unlike the large-scale occupational disease cases, only a few people including expert groups were organized and actively participated in the settlement of these issues, so it remains unfinished business for our society to address.

Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

Case Study of Hong Kong Metro for Improving Indoor Air Quality (홍콩지하철의 실내공기질 개선사례 연구)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1561-1565
    • /
    • 2008
  • More than 3.4 million people use Hong Kong metro a day. It was first constructed in 1979, and extended to 9 operating lines with 168.1km length operated by Hong Kong Mass Transit Railway Corporation (MTR). In Hong Kong, airborne viruses such as avian influenza (bird's flu) and severe acute respiratory syndrome (SARS), air pollution by high-density traffics, bacteria and mold due to relatively high humidity are major concerns on air quality management. In this study, we focused on the cases for improving indoor air quality conducted by Hong Kong MTR currently. The case includes the photocatalytic coatings on knobs (or hand straps) to prevent outbreak of bird's flu and SARS, the high voltage ionizers installed at metro platform, and the periodical radon monitoring.

  • PDF

Analysis of Secondary Battery Based on Image Processing of Computed Tomography (CT 기반 영상처리를 이용한 이차전지의 분석)

  • Jea-Seok Oh;Sang-Yeol Lee;Yoon-Gi Yang;Keun-Ho Rew
    • Journal of Information Technology Applications and Management
    • /
    • v.29 no.6
    • /
    • pp.13-21
    • /
    • 2022
  • In this study, we presented a method to inspect the mechanical defects of 4680 type lithium-ion batteries through image processing method. The raw X-ray images are filtered with CLAHE, then Radon inverse transformations are calculated to reconstruct 3D computed tomography of the battery. Using Haar-cascade, the ROI is targeted automatically, and the template matchings are applied twice. The variations of contrast between template and background show the appropriate values for detecting tabs. It was shown that the proposed algorithm can detect all the tab inside the battery and the distances between tabs. Finally, we successfully found the geometrical defects of battery.

The Assessment of Survey on the Indoor Air Quality at Schools in Korea (국내 일부학교 건축물의 실내공기질 평가)

  • Sohn Jong-Ryeul;Roh Young-Man;Son Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

A Study on the Improvement of Indoor Environment in the Underground Parking Lot of Apartments in Jeonju City (전주시 공동주택 지하주차장의 실내환경 개선에 관한 연구)

  • Jung, Jaeyoun;Jeong, Insoo;Bao, Wei
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • The main purpose of the research is to prevent residents who are using underground parking lot from being exposed to pollusion, and to allow them to enjoy clean indoor environment. The study subject for the research are underground parking lots in 20 different apartments, 4 of them were constructed before 2000, 10 were constructed from 2000-2010, and the rest were constructed after 2010. By analyzing the air quality in these underground parking lots, we found out that O3, NO2, CO, PM10, Radon in all parking lots were not excessive compared to the standard limit. TVOC rate was measured with the value in between 312 ~ 2,137㎍/m3, with CO2 value in between 193~1,824 ppm, and HCHO with the value in between 0.01~1.52ppm. The lightning system in underground parking lots in apartments constructed before 2000 were using manual light control system, while automatic light control system was used in all apartments constructed after 2000, and the brightness of parking lots in apartments constructed before 2000 was quite low. The apartments constructed after 2000 are performing cleaning and ventilation due to management agreement, while the apartments constructed before 2000 are not performing regular cleaning and there was no mechanical ventilation system installed. The difference of indoor air quality was significant seasonally, daily, and yearly (year of construction), while illuminance was significantly different yearly.