• Title/Summary/Keyword: Radiotherapy planning

Search Result 332, Processing Time 0.023 seconds

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Comparison of Three Dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Low Radiation Exposure of Normal Tissue in Patients with Prostate Cancer

  • Cakir, Aydin;Akgun, Zuleyha;Fayda, Merdan;Agaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3365-3370
    • /
    • 2015
  • Radiotherapy has an important role in the treatment of prostate cancer. Three-dimensional conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques are all applied for this purpose. However, the risk of secondary radiation-induced bladder cancer is significantly elevated in irradiated patients compared surgery-only or watchful waiting groups. There are also reports of risk of secondary cancer with low doses to normal tissues. This study was designed to compare received volumes of low doses among 3D-CRT, IMRT and VMAT techniques for prostate patients. Ten prostate cancer patients were selected retrospectively for this planning study. Treatment plans were generated using 3D-CRT, IMRT and VMAT techniques. Conformity index (CI), homogenity index (HI), receiving 5 Gy of the volume (V5%), receiving 2 Gy of the volume (V2%), receiving 1 Gy of the volume (V1%) and monitor units (MUs) were compared. This study confirms that VMAT has slightly better CI while thev olume of low doses was higher. VMAT had lower MUs than IMRT. 3D-CRT had the lowest MU, CI and HI. If target coverage and normal tissue sparing are comparable between different treatment techniques, the risk of second malignancy should be a important factor in the selection of treatment.

Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer

  • Jeong, Yuri;Oh, Jeong Geun;Kang, Jeong Ku;Moon, Sun Rock;Lee, Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.60-67
    • /
    • 2020
  • Purpose: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. Materials and Methods: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD98%, DD2% and DDmean), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. Results: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DDmean (%) for rectum and bladder. Conclusions: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.

Neck dissection for oral squamous cell carcinoma: our experience and a review of the literature

  • Rani, Pooja;Bhardwaj, Yogesh;Dass, Praveen Kumar;Gupta, Manoj;Malhotra, Divye;Ghezta, Narottam Kumar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.299-305
    • /
    • 2015
  • Objectives: This article describes our experience with neck dissection in 10 patients with oral squamous cell carcinoma. Materials and Methods: Between January 2007 and October 2009, 10 patients underwent primary surgery for the treatment of squamous cell carcinoma of the oral cavity. For patients with $N_0$ disease on clinical exam, selective neck dissection (SND [I-III]) was performed. In patients with palpable cervical metastases (N+), modified radical neck dissections were performed, except in one patient in whom SND (I-III) was performed. The histopathologic reports were reviewed to assess the surgical margins, the presence of extra-capsular spread, perineural invasion, and lymphatic invasion. Results: On histopathologic examination, positive soft tissue margins were found in three patients, and regional lymph node metastases were present in five of the ten patients. Perineural invasion was noted in five patients, and extra nodal spread was found in four patients. Regional recurrence was seen in two patients and loco-regional recurrence plus distant metastasis to the tibia was observed in one patient. During the study period, three patients died. Seven patients remain free of disease to date. Conclusion: Histopathological evaluation provides important and reliable information for disease staging, treatment planning, and prognosis. The philosophy of neck dissection is evolving rapidly with regard to the selectivity with which at-risk lymph node groups are removed. The sample size in the present study is small, thus, caution should be employed when interpreting these results.

The Response of Parenchymal Mass and Airway Obstruction from Lung Cancer to Radiation Therapy (단순 흉부 X-선 사진상 폐암 소견에 대한 방사선 치료의 효과 -단기 추적 조사를 중심으로-)

  • Kang, Cheol-Hoon;Shin, Sei-One;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.227-233
    • /
    • 1989
  • From April 1986 to Dec 1988, fifty one patients with carcinoma of lung were treated by radiation therapy in Department of Therapeutic Radiology, Yeungnam University Hospital Of the 51 patients, $31(61\%)$ were squamous cell ca, $8(15.7\%)$ were small cell ca, and remained $4(7.9\%)$ were other cell types. Total radiation dose was average $64Gy (60\~75 Gy)$ for group A and 45Gy $(40\~59Gy)$ for group B. The mass regression and the response of airway obstruction to radiation therapy was established on the basis of follow up chest X-ray. The mass regression above $50\%$ of total volume was noted in 23 patients $(74.2\%)$ among 31 patients and the difference between two groups was not seen. In squamous cell ca, however, the mass regression rate (above $50\%$ of total volume) was $83.3\%$ (10/12) in group A compared to $50\%$ (3/6) in group B(p<0.05). The alleviation of airway obstruction was noted as follows. In group A, CR $42.9\%$, PR $35.7\%$, no response $21.4\%$ and in group B, CR $55.6\%,\;PR\;33.3\%$, no response $11.1\%$. But, in squamous cell ca, responsiveness is higher than group B. The study indicates that the importance of higher radiation dose in the management of primary tumor mass and airway obstruction caused by lung cancer especially squamous cell ca. So, meticulous treatment planning and multimodality combination therapy without increasing si.do elect or complication is recommended in management of inoperable bronchogenic carcinoma.

  • PDF

Piroxicam, Mitoxantrone, and Hypofractionated Radiation Therapy with Volumetric Modulated Arc Therapy for Treating Urinary Transitional Cell Carcinoma in a Dog: A Case Report

  • Hwang, Tae-Sung;An, Soyon;Choi, Moon-Young;Huh, Chan;Song, Joong-Hyun;Jung, Dong-In;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.39 no.1
    • /
    • pp.16-22
    • /
    • 2022
  • A 12-year-old spayed female beagle dog was presented with pollakiuria and stranguria. Abdominal ultrasonography identified irregular a marginated, hyperechoic mass in the urethra and trigon area of the bladder. Computed tomography (CT) revealed a heterogeneous mass in the trigone area leading to a urethra. There was no evidence of regional or distant metastasis. Cytologic analysis suspected transitional cell carcinoma (TCC). The patient was treated with piroxicam, mitoxantrone, and once weekly fractionated radiation therapy (RT) with volumetric modulated arc therapy (VMAT). A follow-up CT scan at 6 months after RT revealed a reduction in tumor size. At 17 months after the start of RT, the patient became severely anorectic and lethargic. Ultrasound examination revealed a hyperechoic mass in the apex area of bladder while the trigone area of the bladder and urethra appeared normal. Multiple hypoechoic nodules of various sizes were found in the liver and spleen. The patient was humanely euthanized at the request of the owner. A combination of piroxicam, mitoxantrone, and hypofractionated RT with VMAT protocol was well tolerated. This case described tumor response and survival time of a canine TCC treated with piroxicam, mitoxantrone, and once weekly palliative RT using computer-assisted planning and VMAT.

Assessment of Abdominal Organs Movement by Respiration Using Computed Tomography in Dogs: A Pitfall for Radiation Therapy

  • Ah Reum Kim;Soyon An;Gunha Hwang;Moonyeong Choi;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.104-112
    • /
    • 2023
  • The change in the position of the abdominal organs due to movement by respiration is one of the reasons behind inaccurate irradiation of organs during radiotherapy (RT). Although studies in human medicine have revealed on the respiratory movements of abdominal organs, there is little information and no reference data for dogs. The purpose of this study was to establish the reference values of abdominal organs movement in various postures using computed tomography (CT), and to compare the movements of organs between dorsal recumbency and ventral, right and left lateral recumbency during respiration. CT images for kidney, adrenal gland, medial iliac lymph node, urinary bladder, gallbladder, liver, stomach, and thoracic and lumbar vertebral body of five beagle dogs were acquired. The movements of organs were evaluated by comparing the end-expiratory and end-inspiratory images. Movements of the organs were evaluated by dividing it into right-to-left, dorsal-to-ventral, and cranial-to-caudal directions. The movements of abdominal organs according to the change in postures and respiration were establish. The movement of the bilateral organs was the least when the organs were in the downward position (p < 0.017). The movement of cranial-to-caudal direction was greater than the movement of the other directions in most of the organs. Data obtained in this study may be useful in selecting the appropriate posture that can reduce the movements of organs to be treated with RT, and the data could be useful for setting the planning target volume to consider the movements of the abdominal organs by respiration.

Development of the Whole Body 3-Dimensional Topographic Radiotherapy System (3차원 전신 정위 방사선 치료 장치의 개발)

  • Jung, Won-Kyun;Lee, Byung-Yong;Choi, Eun-Kyung;Kim, Jong-Hoon;An, Seung-Do;Lee, Seok;Min, Chul-Ki;Park, Cham-Bok;Jang, Hye-Sook
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1999
  • For the purpose of utilization in 3-D conformal radiotherapy and whole body radiosurgery, the Whole Body 3-Dimensional Topographic Radiation Therapy System has been developed. Whole body frame was constructed in order to be installed on the couch. Radiopaque catheters were engraved on it for the dedicated coordinate system and a MeV-Green immobilizer was used for the patient setup by the help of side panels and plastic rods. By designing and constructing the whole body frame in this way, geometrical limitation to the gantry rotation in 3-D conformal radiotherapy could be minimized and problem which radiation transmission may be altered in particular incident angles was solved. By analyzing CT images containing information of patient setup with respect to the whole body frame, localization and coordination of the target is performed so that patient setup error may be eliminated between simulation and treatment. For the verification of setup, the change of patient positioning is detected and adjusted in order to minimize the setup error by means of comparison of the body outlines using 3 CCTV cameras. To enhance efficiency of treatment procedure, this work can be done in real time by watching the change of patient setup through the monitor. The method of image subtraction in IDL (Interactive Data Language) was used to visualize the change of patient setup. Rotating X-ray system was constructed for detecting target movement due to internal organ motion. Landmark screws were implanted either on the bones around target or inside target, and variation of target location with respect to markers may be visualized in order to minimize internal setup error through the anterior and the lateral image information taken from rotating X-ray system. For CT simulation, simulation software was developed using IDL on GUI(Graphic User Interface) basis for PC and includes functions of graphic handling, editing and data acquisition of images of internal organs as well as target for the preparation of treatment planning.

  • PDF

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

Location Error of the Dens in a Two-Dimensional Set-up Verification During Head and Neck Radiotherapy (뇌.두경부 방사선치료 시 전자조사문영상장치를 이용한 세트업 오차 확인에서 제2경추 치상돌기 위치의 임상적 의의)

  • Kim, Dong-Hyun;Kim, Won-Taek;Ki, Yong-Gan;Nam, Ji-Ho;Lee, Mi-Ran;Jeon, Ho-Sang;Park, Dal;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.107-114
    • /
    • 2011
  • Purpose: To assess the degree and clinical impact of location error of the dens on the X-axis during radiotherapy to brain and head and neck tumors. Materials and Methods: Twenty-one patients with brain tumors or head and neck tumors who received three-dimensional conformal radiation therapy or intensity-modulated radiation therapy from January 2009 to June 2010 were included in this study. In comparison two-dimensional verification portal images with initial simulation images, location error of the nasal septum and the dens on the X-axis was measured. The effect of set-up errors of the dens was simulated in the planning system and analyzed with physical dose parameters. Results: A total of 402 portal images were reviewed. The mean location error at the nasal septum was 0.16 mm and at the dens was 0.33 mm (absolute value). Location errors of more than 3 mm were recorded in 43 cases (10.7%) at the nasal septum, compared to 133 cases (33.1%) at the dens. There was no case with a location error more than 5 mm at the nasal septum, compared to 11 cases (2.7%) at the dens. In a dosimetric simulation, a location error more than 5 mm at the dens could induce a reduction in the clinical target volume 1 coverage (V95: 100%${\rightarrow}$87.2%) and overdosing to a critical normal organ (Spinal cord V45: <0.1%${\rightarrow}$12.6%). Conclusion: In both brain and head and neck radiotherapy, a relatively larger set-up error was detected at the dens than the nasal septum when using an electronic portal imaging device. Consideration of the location error of the dens is necessary at the time of the precise radiation beam delivery in two-dimensional verification systems.