• Title/Summary/Keyword: Radiotherapy

Search Result 2,766, Processing Time 0.035 seconds

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Serum ghrelin and leptin concentrations in children with cancer : comparisons with normal children (소아 종양 환아의 혈중 Ghrelin과 Leptin의 농도: 정상 소아와 비교)

  • Park, So Hyun;Jung, Min Ho;Chung, Nac Gyun;Suh, Byung-Kyu;Lee, Byung Churl
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.905-911
    • /
    • 2007
  • Purpose : Ghrelin, being secreted from the stomach, stimulates growth hormone secretion and controls energy homeostasis by increasing appetite. Leptin, being secreted from the adipocytes, controls weight and energy homeostasis by decreasing appetite. Leptin concentration is reported to increase after childhood cancer therapy. This study was aimed to compare ghrelin and leptin concentrations in normal children and children who received cancer therapy. Methods : We enrolled forty-three patients who were diagnosed with cancer and received radiotherapy or chemotherapy during Dec. 2004 through Dec. 2005 in St. Marys hospital and Kangnam St. Marys hospital. Forty-five healthy children were selected as a control group whose age, gender, weight and height were similar to those of cancer group. The serum leptin and ghrelin concentrations were also measured by radioimmunoassay. Results : The cancer group showed higher BMI and leptin concentrations. The control group showed higher concentrations of ghrelin. Both control and cancer groups revealed positive correlations between leptin concentrations and BMI. Ghrelin concentrations in the control group showed negative correlations with age, height, weight and BMI but no significant correlation was found in the cancer group. All the parameters in the group treated with chemotherapy only were not different from those in the group treated with chemotherapy and irradiation. But the level of ghrelin in the acute myeloid leukemia group was much higher than those in the acute lymphoblastic leukemia group. Conclusion : Patients with pediatric cancer treatment have presented higher BMI and leptin concentrations but lower ghrelin concentrations than those in healthy children. Because of the relatively short duration and cross sectional method of the study, however, further long term and prospective study will be required in the future.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Survival Results and Prognostic Factors in T4 N0-3 Non-small Cell Lung Cancer Patients According to the AJCC 7th Edition Staging System

  • Arslan, Deniz;Bozcuk, Hakan;Gunduz, Seyda;Tural, Deniz;Tattli, Ali Murat;Uysal, Mukremin;Goksu, Sema Sezgin;Bassorgun, Cumhur Ibrahim;Koral, Lokman;Coskun, Hasan Senol;Ozdogan, Mustafa;Savas, Burhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2465-2472
    • /
    • 2014
  • Background: The American Joint Committee on Cancer (AJCC) published a new staging system ($7^{th}$ edition) in 2009. In our study, we evaluated the survival results and prognostic factors among T4 local advanced non-small cell lung cancer (LA-NSCLC) patients in a large heterogeneous group, in accordance with this new system. Materials and Methods: We retrospectively evaluated the files of 122 T4 N0-3 M0 LA-NSCLC patients, identified according to the new staging system, treated at two centers between November 2003 and June 2012. Variables correlating with univariate survival at p<0.20 were later included in multivariate Cox regression analysis. Here, selection of relevant predictors of survival was carried out in accordance with the likelihood ratio formula with p<0.05 regarded as significant. Results: The median age was 60 and the median follow-up period was 17.4 months. Median overall survival (OS) was 18.3 months, the 1 year overall survival (OS) rate was 72%, and the 5 year OS rate was 28%. Statistically significant predictors of survival were (p<0.20) ECOG-PS (Eastern Cooperative Oncology Group Performance Status), age, T4 factor subgroup, stage and primary treatment in OS univariate analysis. On multivariate analysis for OS ECOG-PS (p=0.001), diagnostic stage (p=0.021), and primary treatment (p=0.004) were significant. In the group receiving non-curative treatment, the median OS was 11.0 months, while it was 19.0 months in the definitive RT group and 26.6 months in the curative treatment group. There was a significant difference between the non-curative group and the groups which had definitive RT and curative operations (respectively p<0.001 and p=0.001) in terms of OS, but not between the groups which had definitive RT and curative operations. The median event free survival (EFS) rate was 9.9 months, with rates of 46% and 19% at 3 and 5 years, respectively. On univariate analysis of EFS rate with ECOG-PS, weight loss and staging, statistical significance was found only for thorax computerized tomography (CT)+18F-fluorodeoxy-glucose positron emission tomography-CT (PET-CT) use, stage and primary treatment (p<0.20). In multivariate analysis with EFS, only the primary treatment was statistically significant (p=0.001). In the group receiving non-curative treatment, the median EFS was 10.5 months while in the curative operation group it was 14.7 months. When all the primary treatment groups were taken into consideration, grade III/IV side effect swas observed in 57 patients (46.6%). Esophagitis was most prominent among those that received definitive radiotherapy. Conclusions: Independent prognostic factors among these 122 heterogeneous LA-NSCLC T4 N0-3 M0 patients were age at diagnosis, ECOG-PS, stage and primary treatment, the last also being a significant prognostic indicator of EFS. Our findings point to the importance of appropriate staging and a multidisciplinary approach with modern imaging methods in this patient group. In those with T4 lesions, treatment selection and the effective use of curative potential should be the most important goal of clinical care.

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Development of Abdominal Compression Belt and Evaluation of the Efficiency for the Reduction of Respiratory Motion in SBRT (체부 정위방사선치료 시 호흡운동 감소를 위한 복부 압박기구 개발 및 유용성 평가)

  • Hwang, Seon-Bung;Kim, Il-Hwan;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Jeong, Seong-Min;Kim, Gi-Hwan;Lee, Ah-Ram;Cho, Yu-Ra
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • Purpose: It's essential to minimize the tumor motion and identify the exact location of the lesions to achieve the improvement in radiation therapy efficiency during SBRT. In this study, we made the established compression belt to reduce respiratory motion and evaluated the usefulness of clinical application in SBRT. Materials and Methods: We analyzed the merits and demerits of the established compression belt to reduce the respiratory motion and improved the reproducibility and precision in use. To evaluate the usefulness of improved compression belt for respiratory motion reduction in SBRT, firstly, we reviewed the spiral CT images acquired in inspiration and expiration states of 8 lung cancer cases, respectively, and analyzed the three dimensional tumor motion related to respiration. To evaluate isodose distribution, secondly, we also made the special phantom using EBT2 film (Gafchronic, ISP, USA) and we prepared the robot (Cartesian Robot-2 Axis, FARARCM4H, Samsung Mechatronics, Korea) to reproduce three dimensional tumor motion. And analysis was made for isodose curves and two dimensional isodose profiles with reproducibility of respiratory motion on the basis of CT images. Results: A respiratory motion reduction compression belt (Velcro type) that has convenient use and good reproducibility was developed. The moving differences of three dimensional tumor motion of lung cancer cases analyzed by CT images were mean 3.2 mm, 4.3 mm and 13 mm each in LR, AP and CC directions. The result of characteristic change in dose distribution using the phantom and rectangular coordinates robot showed that the distortion of isodose has great differences, mean length was 4.2 mm; the differences were 8.0% and 16.8% each for cranio-caudal and 8.1% and 10.9% each for left-right directions in underdose below the prescribed dose. Conclusion: In this study, we could develop the convenient and efficient compression belt that can make the organs' motion minimize. With this compression belt, we confirmed that underdose due to respiration can be coped with when CTV-PTV margins of mean 6 mm would be used. And we conclude that the respiratory motion reduction compression belt we developed can be used for clinical effective aids along with the gating system.

  • PDF

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients (유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가)

  • Jung, In Ho;Kim, Joon Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • Purpose : We investigated the safety of Intrabeam$^{TM}$ system, X-ray unit for Intraoperative Radiotheray (IORT) by measuring surface dose using Optically Stimulated Luminescent Dosimeter(OSLD). Materials and Methods : 30 patients were selected, who were in breast cancer patients and had an operation of breast conserving surgery (BCS). At the inner surface of tumor bed, 20 Gy were described, and 5 Gy at 1cm depth from the inner surface. Along the size of tumor bed which could be decided after resection of tumor, the size of applicator were determined. Usual treatment time were from 18 to 40 minutes. For the measurement of surface doses, OSLD were placed at superior(U1,2), inferior(D1,2), lateral(L1,2) and medial(M1,2) directions from the center of applicator. Each direction, two OSLD were placed at 0.5 cm and 1.5 cm from the center. Mean, maximum, and minimum doses were analyzed to be compared. Results : Mean values were U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, and M2 $1.51{\pm}0.58Gy$. Maximum values were 4.34 Gy at U1, and Minimum values were 0.45 Gy at M2. 13.3 % of patient (4pts out of 30) were reported that surface dose were over 4 Gy. Conclusion : The fact that skin dose of all patients were less than 5 Gy based on OSLD measurement showed the safety of Intrabeam$^{TM}$ system. In the relatively small breast volume, the tendency that surface dose was increased had been shown, which was analyzed by the data of patients who irradiated over 4Gy at skin surface. Therefore, for appropriate indication for IORT, it is suggested that breast volume as well as the size and position of tumor should be carfully considered.

  • PDF

Comparison of Beam Transfer Methods between Tomo Therapy and Proton Therapy for Prostate Cancer Radiation Therapy (전립선암 방사선 치료 시 토모치료와 양성자치료 빔 전달방식 비교)

  • Park, Jung Min;Ko, Eun Seo;Lee, Jin Hee;Kim, Jin Won;Yang, Jin Ho;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Tomo therapy and Proton therapy treatment plans for the treatment of prostate cancer patients were established, and the characteristics of dose distribution according to beam delivery method using Tomo therapy IMRT method and Proton therapy PBS method to compare and analyze the treatment effect were sought. Materials and Methods: Tomo IMRT treatment plan and Proton PBS treatment plan were established using the Hi.art planning station 5.1.1.6 of Tomo therapy and Eclipse 13.7 of VARIAN for three prostate cancer patients who were treated with radiotherapy only for radical purposes without surgery. For the evaluation of two treatment plans, the average dose (Dmean) and maximum dose (Dmax) of PGTV were calculated from dose volume histogram (DVH) to confirm the coverage and calculate CI and HI. In OAR evaluation, the dose received from the rectal volume 25% and the dose received from the bladder were evaluated to compare the normal long-term protection effect. Results: The mean maximum doses of the three patients were 71.4Gy, 75.3Gy and the mean doses were 70.4Gy and 72.8Gy in the DVH of the Tomo IMRT and Proton PBS. The CI was 1.16 and 1.31, and the HI was 0.04 and 0.12 respectively, and the Tomo IMRT was superior to the Proton PBS in dose suitability. Conclusion: The mean dose of PGTV in prostate cancer patients was 3.4% higher in Proton PBS than in Tomo IMRT. This is because the Dose suitability of Tomo IMRT was better, but it is considered to be a small difference to be seen as a significant result. However, the results of the two methods were 51.2% in D 25% and 55.7% less in the average dose of bladder, which could reduce the side effects of patients in proton PBS.

Radiation Therapy of Intracranial Germinomas : Optimum Radiation Dose and Treatment Volume (두개내 배아종의 방사선치료:적정 방사선량 및 치료용적)

  • Chang, Sei-Kyung;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.269-274
    • /
    • 1999
  • Purpose : To evaluate the Possibility of decreasing the radiation dose and to determine optimum treatment volume in intracranial germinomas. Materials and Methods : Forty five patients with pathologically-verified or presumed germinomas by a radiosensitivity test who had been treated with radiotherapy (RT) alone between 1971 and 1992 were retrospectively analyzed. The average age was 17.2 years with 68.9$\%$ of the patients being between the ages of 10$\~$20. The male and female ratio was 2.2:1. The locations of the primary tumors were at the pineal regions in 14 patients; the suprasellar regions in 12 patients; and multiple sites in 12 patients. Treatment volumes varied from a small local field (10) to the whole brain (7) or entire neuroaxis irradiation(28). All the cases after 1982 received craniospinal irradiation (CSI). Radiation doses were 41-59 Gy (median 48.5 Gy) to the primary tumor site and 19.5$\~$36 Gy (median 24 Gy) to the neuroaxis. The median follow-up period was 82 months with a range of 2$\~$260 months. Results : All the patients showed complete response after RT. Four patients sufferred from recurrence 14, 65, 76, and 170 months after RT, respectively, and two patients died with intercurrent disease. One of four recurrent cases was salvaged by re-irradiation. Therefore, a 5 and 10 year overall suNival was 95.3$\%$ and 84.7 $\%$ respectively. Five and ten year disease-free survival was 97.6 $\%$ and 88.8 $\%$ respectively. All the recurrences occurred in the patients who received local RT (3/10) or whole brain RT (1/7) with a radiation dose of 48-50 Gy. None of the patients who received CSI suffered recurrence. There was no recurrence among the 15 patients who received $\leq$45 Gy to the primary site and the 18 patients who received $\leq$24 Gy (6 patients received 19.5 Gy) to the neuroaxis. Conclusion : CSI is recommended for the treatment of intracranial germinomas. The radiation dose can be safely decreased to $\leq$45 Gy on a primay tumor site and 19.5 Gy on the spine.

  • PDF