• 제목/요약/키워드: Radioluminescence

검색결과 3건 처리시간 0.022초

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Some aspects of scintillation mechanism in organic molecular dielectrics

  • Galunov, N.Z.;Grinev, B.V.;Tarasenko, O.A.;Martynenko, E.V.
    • Journal of Radiation Protection and Research
    • /
    • 제30권2호
    • /
    • pp.85-89
    • /
    • 2005
  • Aspects of the scintillation mechanism in organic systems obtained on the base of precise measurements of the radioluminescence pulse shape are discussed. It shown that the process of scintillation light pulse formation is mainly determined by initial conditions of exited states generation.

Phoswich 검출기 제작을 위한 무기 섬광체 특성 연구 (A Study of the Inorganic Scintillator Properties for a Phoswich Detector)

  • 이우교;김용균;김종경
    • Journal of Radiation Protection and Research
    • /
    • 제29권4호
    • /
    • pp.251-256
    • /
    • 2004
  • Phoswich 검출기를 제작하기 위하여 무기 섬광체인 CsI(Tl), $CdWO_4(CWO),\;Bi_4Ge_3O_{12}(BGO)$$Gd_2SiO_5:Ce(GSO)$의 특성을 연구하였다. CsI(Tl), CWO, BGO 및 GSO 섬광체의 radioluminescence 중심파장은 550 nm, 475 nm, 490 nm 및 440 nm이였고, neutral filter를 사용하여 측정한 CsI(Tl), CWO, BGO 및 GSO 섬광체의 절대광량은 각각 54890 phonon/MeV, 17762 phonon/MeV, 8322 phonon/MeV 및 8932 phonon/MeV이였으며, single photon method로 측정한 형광감쇠시간은 각각 $1.3{\mu}s,\;8.17{\mu}s$, 213 ns 및 37 ns이였다. 플라스틱 섬광체와 CsI(Tl) 섬광체를 사용하여 phoswich 검출기를 제작하였고 PSD(pulse shape discriminator) 방법으로 ${\beta}$ 입자와 ${\gamma}$ 선을 구별하며 각각의 방사선에 대한 파고 스펙트럼을 측정하였다.