• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.028 seconds

Cases report of ossifying fibroma showing various radiographic appearances in posterior mandible (하악골 후방부위에서 다양한 방사선학적 소견을 보이는 골화성섬유종의 증례보고)

  • Lee, Byung-Do;Oh, Seung-Hwan;Son, Hyun-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.53-58
    • /
    • 2010
  • Common radiographic appearances of ossifying fibroma (OF) are well demarcated margin, radiolucent or mixed lesion. Lesions for the radiographic differential diagnosis with OF include fibrous dysplasia, focal cemento-osseous dysplasia. Other confusing lesions might be the mixed lesions such as calcifying odontogenic cyst, adenomatoid odontogenic tumor, calcifying epithelial odontogenic tumor, and benign cementoblastoma. We reported three cases of OF in posterior mandible. These cases showed a little distinguished radiographic features of OF and diagnosed from a combination of clinical, radiographic, and histopathologic information. We need to further refine radiographic and histopathological features of OF and other confusing lesions with literatures review because some cases of these lesions are not easily differentiated radiographically and histopathologically.

Odontogenic myxoma: a case report with recent image modalities

  • Kim Jae-Duk;Kim Kwang-Won;Lim Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.199-202
    • /
    • 2004
  • The odontogenic myxoma is an benign, slow growing neoplasm which is of ectomesenchymal origin. This neoplasm occurs almost exclusively in the jaw bones and comprises 0.2% to 17.7% of odontogenic tumors. The odontogenic myxoma may show a wide spectrum of radiographic appearances, unilocular, multilocular radiolucency and a distinct or diffuse border, making the differential diagnosis difficult. We present a case of the odontogenic myxoma in the maxilla with conventional and recent image modalities. Occlusal film revealed a medially extended multilocular lesion with intralesional fine and straight trabeculations from the scalloped margin and buccal expansion and thinning of cortical bone. Computed tomogram revealed lesion showed equivalent density to the muscles in the left maxillary sinus with partial cortical discontinuity of medial wall and the tennis-racket pattern with internal straight trabeculations. MRI revealed intermediate signal intensity on Tl weighted image and high signal intensity on T2 weighted image. In Gd enhanced MR image, the peripheral portions of the lesion were enhanced.

  • PDF

CBCT analysis of three implant cases for treatment planning (임플란트 치료 전 CBCT 영상분석 세 증례)

  • Kim, Jae-Duk;Kim, Kwang-Won;Lim, Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

Multiple idiopathic external and internal resorption: Case report with cone-beam computed tomography findings

  • Celikten, Berkan;Uzuntas, Ceren Feriha;Kurt, Hakan
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.315-320
    • /
    • 2014
  • Root resorption is loss of dental hard tissue as a result of clastic activities. The dental hard tissue of permanent teeth does not normally undergo resorption, except in cases of inflammation or trauma. However, there are rare cases of tooth resorption of an unknown cause, known as "idiopathic root resorption". This report would discuss a rare case of multiple idiopathic resorption in the permanent maxillary and mandibular teeth of an otherwise healthy 36-year-old male patient. In addition to a clinical examination, the patient was imaged using conventional radiography and cone-beam computed tomography (CBCT). The examinations revealed multiple external and internal resorption of the teeth in all four quadrants of the jaws with an unknown cause. Multiple root resorption is a rare clinical phenomenon that should be examined using different radiographic modalities. Cross-sectional CBCT is useful in the diagnosis and examination of such lesions.

Extraoral periapical radiography: an alternative approach to intraoral periapical radiography

  • Kumar, Rahul;Khambete, Neha;Priya, Ekta
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.161-165
    • /
    • 2011
  • It is difficult to take intraoral radiographs in some patients who are intolerable to place the film in their mouth. For these patients, Newman and Friedman recommended a new technique of extraoral film placement. Here we report various cases that diagnostic imaging was performed in patients using the extraoral periapical technique. This technique was used to obtain the radiographs for the patients with severe gag reflex, pediatric dental patients, and patients with restricted mouth opening. This technique can be recommended as an alternative to conventional intraoral periapical technique in cases where intraoral film placement is difficult to achieve.

Facile Preparation of Pyrene-templated Hexagonal-shaped Gold Nanoplates

  • Lim, Eun-Kyung;Jang, Eunji;Haam, Seungjoo;Huh, Yong-Min
    • Applied Science and Convergence Technology
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2014
  • We have formulated hexagonal-shaped gold nanoplates in a single-step for photothermal therapy that gold ions to gold particles using pyrenyl dextran as reducible stabilizer and template. They exhibit anisotropic structure with broad surface plasmon resonance (SPR) band into near-infrared (NIR) spectrum enabling photothermal therapy. These gold nanoplates are also confirmed biocompatibility and high uptake efficiency due to binding with dextran molecules on the surface of gold nanoplates and cells. From in vitro phtothermal ablation study under NIR laser, gold nanoplates have the potential to use as photothermal agents.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

Submandibular sialolithiasis with CT and scintigraphy: CT values and salivary gland excretion in the submandibular glands

  • Ogura, Ichiro;Hayama, Kazuhide;Sue, Mikiko;Oda, Takaaki;Sasaki, Yoshihiko
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: Sialolithiasis is one of the most prevalent large obstructive disorders of the submandibular glands. The aim of this study was to investigate submandibular sialolithiasis with computed tomography (CT) and scintigraphy, with a particular focus on the relationship between CT values of the submandibular glands and their excretion rate. Materials and Methods: Fifteen patients with submandibular sialolithiasis who underwent CT and salivary gland scintigraphy were included in this study. The relationship between the CT values of submandibular glands with and without sialoliths and salivary gland excretion measured using salivary gland scintigraphy was statistically analyzed. Dynamic images were recorded on the computer at 1 frame per 20 seconds. The salivary gland excretion fraction was defined as A (before stimulation test [counts/frame]) / B (after stimulation test [counts/frame]) using time-activity curves. Results: The CT values in the submandibular glands with and without sialoliths was $9.9{\pm}44.9$ Hounsfield units(HU) and $34.2{\pm}21.8HU$, respectively (P=.233). Regarding the salivary gland excretion fraction using scintigraphy, the A/B value in the submandibular glands with sialoliths ($1.09{\pm}0.23$) was significantly lower than in the submandibular glands without sialoliths($1.99{\pm}0.57$, P=.000). Conclusion: Assessments of the CT values and the salivary gland excretion fraction using scintigraphy in the submandibular glands seem to be useful tools evaluating submandibular sialolithiasis.

Evaluation of Usefulness of SPIO (Superparamagnetic iron oxide) Contrast Agent in MRCP (Magnetic resonance cholangiopancreatography) (자기공명 담도췌장조영술에서의 SPIO 조영제의 유용성 평가)

  • Hong, In-Sik;Lee, Hae-Kak;Cho, Jae-Hwan;Kim, Hyeon-Ju;Jang, Hyun-Cheol;Park, Cheol-Soo;Lee, Sun-Yeob;Goo, Eun-Hoe;Dong, Kyung-Rae;Cho, Moo-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of SPIO contrast agent in Magnetic Resonance Cholangiopancreatography (MRCP) by performing a quantitative comparative analysis in patients undergoing MRCP for gallbladder stones with and without oral injection of SPIO (Superparamagnetic iron oxide) contrast agent. The subjects were 36 patients undergoing MRCP for suspected gallbladder stones between January 2009 and February 2010 and they were divided into halves to compare the two groups of with and without SPIO agent. For each subject in both the injected and non-injected group, T2-weighted images on a 1.5T MR scanner were obtained, using both the breath-holding and respiratory-triggered methods, respectively. The following regions were measured; for breath-hold T2-weighted images, the measurement regions were located at the central part of the gallbladder, and the areas 15 mm away from its center, toward the front and back, respectively, which were chosen to include surrounding tissues, while for respiratory-triggered T2-weighted images, at the central part of the gallbladder, and segment 5 and 6 of liver. In a quantitative analysis, average signal to noise ratio (SNR) in each of regions of interest (ROI) for each group were calculated and then average contrast to noise ratio (CNR) in each of ROI were obtained by using the SNR in the gallbladder as the basis to compare and analyze the values between the two groups. The CNR were higher for the injected group in those regions.

The Evaluation of the Thick Polycrystalline HgO and PbO Films Derived by Particle Sedimentation Method for the Mammographic Application (입자침전법을 이용한 다결정 산화수은과 산화납 필름의 방사선 유방촬영 장치 적용성 평가)

  • Noh, Si-Cheol;Park, Ji-Koon;Choi, Il-Hong;Jung, Hyoung-Jin;Kang, Sang-Sik;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.429-433
    • /
    • 2014
  • In this study, the morphology and the x-ray quantum efficient of mercury oxide (HgO) and lead oxide (PbO) sensors derived by particle sedimentation method were discussed. In the pursuit of this purpose, we investigated the electrical characteristics and the x-ray quantum efficiency of various thicknesses of HgO and PbO films in mammographic x-ray energy. We have therefore developed a particle-in-binder sedimentation method of fabricating large area polycrystalline films onto transparent glass substrates coated with indium tin oxide. We are currently optimizing the growth method to improve the quantum efficiency with the ultimate goal of obtaining as quantum efficiency close to that of single crystal performance. Our future efforts will concentrate on optimization of large area film growth techniques specifically for deposition on a-Si:H flat panel readout arrays.