• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

  • Houno, Yuuki;Hishikawa, Toshimitsu;Gotoh, Ken-ichi;Naitoh, Munetaka;Mitani, Akio;Noguchi, Toshihide;Ariji, Eiichiro;Kodera, Yoshie
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.199-207
    • /
    • 2017
  • Purpose: Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Materials and Methods: Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Results: Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Conclusion: Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary.

The Research for Scannogram (Scannogram, Whole Spine image 획득에 관한 연구)

  • Lee, Gwnag-Jae;Go, Shin-Guan;Kim, Uk-Dong;Kim, Shi-Don;Kim, Hyung-Seop
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • I.objective The composition method with acquiring 2${\sim}$5 image not only lack perfection in compensating the geometrical distortion but could also cause inaccurate connection problem of compensating the geometrical distortion but could also cause inaccurate connection problem of continuing bone structure due to the enlargement ratio difference of ruller and bone, density difference in image composition process. This paper studies those mentioned problems through the experiments. II. Object and method Experiment 1 After attaching 3 step wedge(Pb) on detector and 2 ruller on upper, lower part of the step wedge, we have exposed them to create density difference between 1st image and 2nd image, then examined if there were any errors. Experiment 2 1st 100cm ruller was attached on the center of detector, and by escalating the distance between 2nd 100cm ruller and detector 5cm, 10cm, 15cm respectively, we investigated if there any errors caused by enlargement ratio. Experiment 3 The ruller was placed on detector, a joint photographing was performed through spot photographing after fully operating the electric field photographing to include hip joint ${\sim}$ ankle joint part and we have compared the values from two methods. III. Result : A horizontal axis error was caused when photopraphing is not poerated in equal density since the image shifted horizontally in accordance with the difference of Pb step wedge 1 due to the density difference, as the result of Epperiment 1.

  • PDF

Volumetric analysis of normal condyles and those with disc displacement with reduction in the Indonesian population: A CBCT study

  • Nawawi, Azkya Patria;Rikmasari, Rasmi;Kurnikasari, Erna;Oscandar, Fahmi;Lita, Yurika Ambar
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.103-108
    • /
    • 2022
  • Purpose: Disc displacement can cause resorption of the head of the condyle and affect its volume. This study analysed the volume of normal condyles and those with disc displacement with reduction (DDR) in cone-beam computed tomography (CBCT) scans from the Indonesian population. Materials and Methods: This study analysed 56 condyles (26 normal and 30 with DDR) from patients who visited the Oral and Maxillofacial Radiology Unit after being referred from the Prosthodontics Unit at Dental Hospital Universitas Padjadjaran from December 2020 to February 2021. Samples were divided into 2 groups (normal and DDR left and right-side condyles) based on the DC/TMD Axis 1 form through the clinical examination results. Both sample groups were exposed to CBCT radiation. The CBCT imaging results in the Digital Imaging and Communications in Medicine format were exported to the open-source ITK-SNAP format to determine condyle volume. Volumetric data from the cortical and trabecular areas of the right or left side condyles were arranged by sex. The independent t-test was used to determine the significance of differences with IBM SPSS version 21.0. Intra- and inter-observer reliability and validity were tested before determining the volume of the condyles. Results: Normal condyles and DDR condyles showed significant differences in volume (P<0.05). Significant differences were also seen in cortical (P=0.0007) and trabecular (P=0.0045) volumes. There was a significant difference in condylar volume based on sex. Conclusion: The normal condyle volume was significantly different from the DDR condyle volume in both sexes.

Computer Simulation for Effects of Scintillator and Parallel Hole Collimator on Gamma Probe Imaging (섬광체와 평행구멍조준기가 감마프로브 영상에 미치는 영향에 관한 컴퓨터 시뮬레이션)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.563-570
    • /
    • 1998
  • The purpose of this study was to investigate the effects of scintillator and collimator parameters that tradeoff between system sensitivity and spatial resolution. The parameters simulated using Monte Carlo program were scintillator thickness, colimator hole shape, septal thickness, and hole length. The results show that the sensitivity increases exponentially upto about 1 cm of scintillator thickness as the thickness increases. However the sensitivity is almost constant when the scintiallator is thicker than about 1 cm. The simulation of collimator hole shape shows that the hexagonal hole gives the best spatial resolution for the same system sensitivity. The system statical resolution is improved, as both collimator septal thickness and hole length increase, however that system sensitivity is rapidly decreased. In conclusion, The optimization of scintillator and collimator parameters using monte carlo simulation may be useful to develop a high-resolution miniature gamma probe.

  • PDF

Characteristic of Stress According to Student Clinical Training in Department of Radiology (방사선(학)과 학생 임상실습에 따른 스트레스 특성)

  • Baek, Chang-Moo;Chae, Soo-In;Kim, Jeong-Koo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.291-298
    • /
    • 2012
  • Department of radiology implements the hospital-based clinical training to accept medical treatment techniques and to adapt experiences for students. However, it might cause negative effects to training education, leading to doubt about major and pressure about training as lots of students experience clinical treatment and complex stress in unfamiliar environment. Regarding this, pressure element that students can experience and diverse variables of training were compared and analyzed. With students in department of radiology for 6 colleges and universities, from September 15th to October 25th in 2011. The degree of stress for students in training was shown high in the fields of cost(3.06) and trainers(3.02). Value and ideal(2.94), role and experiment(2.93), training environment(2.74) and relationships among trainees(2.64) were followed in the order. Except expense regarding stress from clinical training, but in all factors, women showed higher pressure level than men(P<.05) and in stress range according to BEPSI-K, a meaningful difference was shown in fields of training environment, relationships among trainees and role and experiment(P<.01, P<.001, P<.05). Therefore, It has been confirmed that there is correlation between stress of students and satisfaction for clinical training with each other closely.

Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study

  • Lokade, Joyti;Rawlani, Shivlal;Baheti, Rakhi (Chandak);Roy, Shelly;Chandak, Manoj;Lohe, Vidya
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Exact knowledge of the location and dimension of the pulp chamber help to maintain the pulp healthy during operative procedure and also reduces the risk of perforation of pulp chamber during root canal treatment. This in-vivo study was carried out to measure critical morphology of pulp chamber of mandibular molar using intra-oral periapical radiograph. Materials and Methods: Mandibular molar teeth of 56 patients were evaluated. The mandibular molar teeth whose pulp chamber was not violated by caries, restoration, fracture crown and those having closed apex were included in the study. The intraoral periapical radiographs were taken with paralleling angle technique using radio-opaque grid with 1 mm space. This grid was placed directly on the film. Results: In 94% of the mandibular first molars specimens the pulp chamber ceiling was at the level of the cemento-enamel junction. The measurements showing the lowest percentage variance were buccal cusp to furcation (approximately 11%) and buccal cusp to pulp chamber ceiling (approximately 15%). The distance from the cusp tip to pulp chamber ceiling height was approximately 6.0 mm, the distance from the pulpal floor to the furcation was approximately 3.0 mm, and the average height of a pulp chamber was 1.5 to 2.0 mm. Conclusion: The exact knowledge of distances of pulp chamber from various anatomical landmarks helps in proper assessment of root canals and ultimately avoids the failure of root canal treatment.

Cephalometric landmark variability among orthodontists and dentomaxillofacial radiologists: a comparative study

  • Durao, Ana Paula Reis;Morosolli, Aline;Pittayapat, Pisha;Bolstad, Napat;Ferreira, Afonso P.;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.213-220
    • /
    • 2015
  • Purpose: The aim this study was to compare the accuracy of orthodontists and dentomaxillofacial radiologists in identifying 17 commonly used cephalometric landmarks, and to determine the extent of variability associated with each of those landmarks. Materials and Methods: Twenty digital lateral cephalometric radiographs were evaluated by two groups of dental specialists, and 17 cephalometric landmarks were identified. The x and y coordinates of each landmark were recorded. The mean value for each landmark was considered the best estimate and used as the standard. Variation in measurements of the distance between landmarks and measurements of the angles associated with certain landmarks was also assessed by a subset of two observers, and intraobserver and interobserver agreement were evaluated. Results: Intraclass correlation coefficients were excellent for intraobserver agreement, but only good for interobserver agreement. The least reliable landmark for orthodontists was the gnathion (Gn) point (standard deviation [SD], 5.92 mm), while the orbitale (Or) was the least reliable landmark (SD, 4.41 mm) for dentomaxillofacial radiologists. Furthermore, the condylion (Co)-Gn plane was the least consistent (SD, 4.43 mm). Conclusion: We established that some landmarks were not as reproducible as others, both horizontally and vertically. The most consistently identified landmark in both groups was the lower incisor border, while the least reliable points were Co, Gn, Or, and the anterior nasal spine. Overall, a lower level of reproducibility in the identification of cephalometric landmarks was observed among orthodontists.

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.