• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing (골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도)

  • Kang, Ho-Duk;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Computed tomography and magnetic resonance imaging characteristics of giant cell tumors in the temporomandibular joint complex

  • Choi, Yoon Joo;Lee, Chena;Jeon, Kug Jin;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.149-154
    • /
    • 2021
  • Purpose: This study aimed to investigate the computed tomography and magnetic resonance imaging features of giant cell tumors in the temporomandibular joint region to facilitate accurate diagnoses. Materials and Methods: From October 2007 to June 2020, 6 patients (2 men and 4 women) at Yonsei University Dental Hospital had histopathologically proven giant cell tumors in the temporomandibular joint. Their computed tomography and magnetic resonance imaging findings were reviewed retrospectively, and the cases were classified into 3 types based on the tumor center and growth pattern observed on the radiologic findings. Results: The age of the 6 patients ranged from 25 to 53 years. Trismus was found in 5 of the 6 cases. One case recurred. The mean size of the tumors, defined based on their greatest diameter, was 32 mm (range, 15-41 mm). The characteristic features of all cases were a heterogeneously-enhancing tumorous mass with a lobulated margin on computed tomographic images and internal multiplicity of signal intensity on T2-weighted magnetic resonance images. According to the site of origin, 3 tumors were bone-centered, 2 were soft tissue-centered, and 1 was peri-articular. Conclusion: Computed tomography and magnetic resonance imaging yielded a tripartite classification of giant cell tumors of the temporomandibular joint according to their location on imaging. This study could help clinicians in the differential diagnosis of giant cell tumors and assist in proper treatment planning for tumorous diseases of the temporomandibular joint.

A novel method of objectively detecting tooth ankylosis using cone-beam computed tomography: A laboratory study

  • Luciano Augusto Cano Martins;Danieli Moura Brasil;Deborah Queiroz Freitas;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.61-67
    • /
    • 2023
  • Purpose: The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods: Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test(α=0.05). Results: The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions(P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non-ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas(P>0.05). Conclusion: The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.

Sonographic assessment of carotid intima-media thickness in healthy young Thai adults

  • Wariya Panprasit;Onanong Chai-u-dom Silkosessak;Panida Mukdeeprom;Pornkawee Charoenlarp
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.291-302
    • /
    • 2023
  • Purpose: Early detection of carotid stenosis can reduce cardiovascular risk. In this study, the maximum-carotid intima-media thickness (CIMT), the mean-CIMT, and the presence of plaque were examined in healthy young Thai adults. Additionally, correlations between CIMT and cardiovascular risk factors were assessed. Materials and Methods: Left and right carotid arteries of 302 participants(15-45 years old) were scanned, with CIMT measured at the far walls of the common carotid artery, carotid bulb, and internal carotid artery. Demographics and risk factors were assessed using a questionnaire. Ten random participants were re-scanned after 4 weeks. Results: The study included 123 (40.70%) male and 179 (59.30%) female participants. The max-CIMT, mean-CIMT, and plaque thickness were 0.400±0.100, 0.403±0.095 and 1.520±0.814 mm, respectively. Male participants had significantly higher CIMT values for nearly all locations and age groups. The right-sided CIMT values were higher for all locations. The carotid bulb had the greatest CIMT values(0.437±0.178 mm), followed by the common (0.403±0.095 mm) and internal(0.361±0.099 mm) carotid arteries. Plaque was present in 18 locations (1.00%), affecting 15 participants (4.97%). These plaques were found in the right carotid bulb (n=9; 0.50%), left carotid bulb (n=7; 0.39%), and right internal carotid artery (n=2; 0.11%). Adjusted multivariable regression revealed significant positive associations between CIMT and male, increased age and "other" occupation (P<0.05). Conclusion: Both max-CIMT and mean-CIMT were approximately 0.4 mm. Plaque was observed in 4.97% of patients, with an average thickness of 1.5 mm. The most influential risk factors for increased CIMT were sex, age, and occupation.

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

  • Hyoung-Ho Kim;Kyung-Wuk Kim;Changje Lee;Young Ho Choi;Min Uk Kim;Yasutaka Baba
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1834-1840
    • /
    • 2021
  • Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.

Effects of irradiation on the calcific nodule formation in MC3T3-El osteoblastic cell line (MC3T3-El 골모세포주의 석회화결절 형성에 방사선이 미치는 영향)

  • Kang Ki-Hyun;Lee Sang-Rae;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : To investigate the effects of irradiation on the calcium content and calcific nodule formation in the MC3T3-E1 osteoblastic cell line. Materials and Methods : Cells were irradiated with a single dose of 2,4 and 8 Gy at a dose rate of 5.38 Gy/min using a Cs-137 irradiator. After irradiation, the calcium content and calcific nodule formation were examined on the 1 st, 2nd, 3rd and 4th week. Results : A decreasing dose-dependent tendency of the cell proliferation rate was found in all irradiated groups of this experiment when compared with the unirradiated control group. In accordance with the duration of culture, there was no significant difference in the cell proliferation rate after irradiation of 2 Gy when compared with the unirradiated group, however a decreasing tendency was found in 4 Gy- and 8 Gy-irradiated groups. While an increase in total calcium content after irradiation of 2 Gy was found at week 1, week 2, and week 4, there was a decrease in calcium content at week 1 through 4 in the 8 Gy- irradiated group. Calcific nodule formation was increased in irradiated experimental groups when compared with the unirradiated control group in the 2 Gy-irradiated group, but decreased in the 4 Gy- and 8 Gy-irradiated groups at the same stage. Conclusion : The results showed a mild increasing tendency of the calcific nodule formation after irradiation of 2 Gy. However, a decreased calcific nodule formation in 4 Gy- and 8 Gy-irradiated groups was found. Taken together, the irradiation of 2 Gy mildly activated bone formation, however 4 Gy or 8 Gy suppressed bone formation by decreasing cell numbers in the MC3T3-El osteoblastic cell line.

  • PDF

Effects of 2-deoxy-D-glucose and quercetin on cytokine secretion and gene expression of type I collagen during osteoblastic differentiation in irradiated MC3T3-El cells

  • Song Haeng-Un;Ahn Hyoun-Suk;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.191-198
    • /
    • 2005
  • Purpose: To characterize the effects of 2-deoxy-D-glucose (2DG) and quercetin (QCT) on cytokine secretion of IL-6, $TGF-\beta$ and gene expression of Col I in irradiated MC3T3-E1 cells Materials and Methods: The MC3T3-El cells were cultured in an a-MEM supplemented with 5mM 2DG or 10mM QCT and then the cells were incubated 12h before irradiation with 2, 4, 6, and 8Gy X-ray using a linear accelerator delivered at a dose rate of 1.5Gy/min. Level of IL-6 and $TGF-\beta$ was determined by ELISA. Also expression of Col I was examined by RT-PCR. Results: In accordance with the radiation dose, the amount of $TGF-\beta$ was not different in RA + QCT, but it showed a peak value in control and RA + 2DG at 4Gy on the 3rd day. However, all groups showed a decreasing tendency dose-dependently in RA+QCT on the 7th day (p<0.01). In accordance with the radiation dose, the amount of IL-6 increased dose-dependently in all groups on the 3rd day. On the 7th and 21st day, all groups showed peak values at 4Gy. RA+QCT showed a slightly increased amount of IL-6 at 2Gy, but it showed a slightly decreased amount at 4, 6, and 8Gy. In accordance with the period of culture after irradiation, the expression of Col I increased dose-dependently in RA+QCT. Conclusion: The result showed that QCT acted as radiosensitizer in the secretion of $TGF-\beta$ and gene expression of Col I during differentiation in irradiated MC3T3-E1 cells at the cellular level.

  • PDF

A Study on the Basic Mathematical Competency Levels of Freshmen Students in Radiology Department (방사선과 신입생의 기초 수리능력 수준에 대한 연구)

  • Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.121-127
    • /
    • 2020
  • The era of the Fourth Industrial Revolution is increasingly demanding mathematical competencies for virtual reality (VR), artificial intelligence (AI) and the like. In this context, this study intended to identify the basic mathematical competency levels of university freshman students in radiology department and to provide basic data thereon. For this, the diagnostic assessment of basic learning competencies for the domain of mathematics was conducted from June 17, 2019 to June 28, 2019 among 78 freshman students of radiology department at S university and D university. As a result, the university students' overall basic mathematical competency levels were diagnosed to be excellent. However, their levels in the sectors of the geometry and vector and the probability and statistics were diagnosed to be moderate, with the mean scores of 2.61 points and 2.64 points, respectively, which were found to be lower than those of the other sections. As for basic mathematical competency levels according to genders, the levels of male students and female students were diagnosed to be excellent, with the mean scores of 17.48 points and 16.29 points, respectively, showing no statistically significant difference (p>0.05). Given the small number of subjects and regional restriction, there might be some limitations in the generalization of the findings of the present study to all university freshman students and all departments. The above results suggest that it is necessary to implement various programs such as student level-based special lectures for enhancing basic mathematical competencies relating to major in order to improve the basic mathematical competencies of freshman students in radiology department, and that it is necessary to increase the students' mathematical competencies by offering major math courses in the curriculum and applying teaching-learning methods matching students' levels.

Tumor Habitat Analysis Using Longitudinal Physiological MRI to Predict Tumor Recurrence After Stereotactic Radiosurgery for Brain Metastasis

  • Da Hyun Lee;Ji Eun Park;NakYoung Kim;Seo Young Park;Young-Hoon Kim;Young Hyun Cho;Jeong Hoon Kim;Ho Sung Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.3
    • /
    • pp.235-246
    • /
    • 2023
  • Objective: It is difficult to predict the treatment response of tissue after stereotactic radiosurgery (SRS) because radiation necrosis (RN) and tumor recurrence can coexist. Our study aimed to predict tumor recurrence, including the recurrence site, after SRS of brain metastasis by performing a longitudinal tumor habitat analysis. Materials and Methods: Two consecutive multiparametric MRI examinations were performed for 83 adults (mean age, 59.0 years; range, 27-82 years; 44 male and 39 female) with 103 SRS-treated brain metastases. Tumor habitats based on contrast-enhanced T1- and T2-weighted images (structural habitats) and those based on the apparent diffusion coefficient (ADC) and cerebral blood volume (CBV) images (physiological habitats) were defined using k-means voxel-wise clustering. The reference standard was based on the pathology or Response Assessment in Neuro-Oncologycriteria for brain metastases (RANO-BM). The association between parameters of single-time or longitudinal tumor habitat and the time to recurrence and the site of recurrence were evaluated using the Cox proportional hazards regression analysis and Dice similarity coefficient, respectively. Results: The mean interval between the two MRI examinations was 99 days. The longitudinal analysis showed that an increase in the hypovascular cellular habitat (low ADC and low CBV) was associated with the risk of recurrence (hazard ratio [HR], 2.68; 95% confidence interval [CI], 1.46-4.91; P = 0.001). During the single-time analysis, a solid low-enhancing habitat (low T2 and low contrast-enhanced T1 signal) was associated with the risk of recurrence (HR, 1.54; 95% CI, 1.01-2.35; P = 0.045). A hypovascular cellular habitat was indicative of the future recurrence site (Dice similarity coefficient = 0.423). Conclusion: After SRS of brain metastases, an increased hypovascular cellular habitat observed using a longitudinal MRI analysis was associated with the risk of recurrence (i.e., treatment resistance) and was indicative of recurrence site. A tumor habitat analysis may help guide future treatments for patients with brain metastases.