• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.037 seconds

A Computed Tomographic Study on the Size and Bone Wall Thickness of the Maxillary Sinus in Normal, Preoperative and Postoperative Maxillary Sinusitis Patients (술전ㆍ후 상악동염환자와 정상인의 상악동 크기 및 골벽두께에 관한 전산화단층방사선학적 연구)

  • Choi Sun-Young;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.109-116
    • /
    • 2000
  • Purpose : To compare the size and bone wall thickness of the maxillary sinus in normal, preoperative and postoperative maxillary sinusitis patients. Materials and Methods : The author analyzed CT images of both left and right maxillary sinuses in 357 patients who visited Chonbuk National University Hospital between January 1997 and December 1998. The size and bone wall thickness of the maxillary sinus of normal, inflammatory and post-Caldwell-Luc groups were compared. Results: The significant differences of transverse, maximum medio-lateral, maximum supero-inferior dimensions and medio-lateral dimension at nasal floor level between normal and post-Caldwell-Luc groups were found (P<0.05). And the significant differences of antero-posterior dimensions between inflammatory and post-Caldwell-Luc group were found (P<0.05). But, no significant differences of vertical height dimensions between groups was found (P>0.05). The significant differences of postero-lateral, infero-lateral and medial wall thickness between normal and post-Caldwell-Luc groups were found (P<0.05). Conclusion : The results of this study will aid in the diagnosis and treatment of maxillary sinus diseases and post operative treatment planning.

  • PDF

Effects of irradiation on the mRNA expression of the osteocalcin and osteopontin in MC3T3-E1 osteoblastic cell line (MC3T3-E1 조골세포주의 osteocalcin과 osteopontin mRNA 발현에 미치는 방사선의 영향)

  • Cho Su-Beom;Lee Sang-Rae;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.179-185
    • /
    • 2003
  • Purpose: To investigate the effects of irradiation on the phenotypic expression of the MC3T3-El osteoblastic cell line, particularly on the expression of osteocalcin and osteopontin. Materials and Methods: Cells were irradiated with a single dose of 0.5, 1,4, and 8 Gy at a dose rate of 5.38 Gy/min using a cesium 137 irradiator. After the specimens were harvested, RNA was extracted on the 3rd, 7th, 14th, and 21st day after irradiation. The RNA strands were reverse-transcribed and the resulting cDNAs were subjected to amplification by PCR. Results: The irradiated cells demonstrated a dose-dependent increase in osteocalcin and a dose-dependent decrease in osteopontin mRNA expression compared with the non-irradiated control group, The amount of osteocalcin mRNA expression decreased significantly at the 3rd day after irradiation of 0,5, 1,4, and 8 Gy, and also decreased significantly at the 3rd, 14th, and 21 st day after irradiation in the 8 Gy exposed group compared with the control group, The degree of osteopontin mRNA expression increased significantly at the 7th day after irradiation of 0,5, 1,4, and 8Gy, Conclusion: These results showed that each single dose of 0,5, 1, 4, and 8 Gy influenced the mRNA expression of osteocalcin and osteopontin associated with the calcification stage of osteoblastic cells, suggesting that each single dose affected bone formation at the cell level.

  • PDF

Dose Assessment during Pregnancy in Abdominal X-ray Examinations (복부 진단 X선 검사 시 태아 및 임산부의 선량 평가)

  • Woo, Ri-Won;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.261-270
    • /
    • 2020
  • In diagnostic X-ray examinations, dose assessments for pregnant female and fetus are realistically difficult, and related research is also lacking. Therefore, in this study, the purpose of the simulation was to analyze the dose and fetal dose for pregnant female during abdominal X-ray examination. Based on the data presented in ICRP 89, this study produced phantom reconstructed of the existing prenatal phantom, which was used to analyze the evaluation of the organ dose and fetal dose of pregnant female according to pregnancy week and the difference between the dose of the existing phantom and the reconstructed phantom. As a result, the abdominal X-ray test showed a tendency to show higher doses for organs close to the direction of the source joining. In addition, it was confirmed that fetal doses in posteroanterior position were reduced by more than 65% compared with anteroposterior position.

Dose Assessment during Pregnancy in Chest PA Examination (흉부 후전방향 검사 시 임산부의 선량 평가)

  • Woo, Ri-Won;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.661-668
    • /
    • 2020
  • One of the causes of death for pregnant female is embolism, when a chest PA examination is performed. In addition, due to small doses, the examinations are performed for the purpose of preparing for pre-delivery emergency surgery or basic examination for pregnant female. Evaluating fetal doses through actual measurements is subject to ethical problems, Monte Carlo simulations assesses the organ and fetal doses of pregnant females according to week of pregnancy. The results of the simulations showed that the fetal dose decreased according to weeks of pregnancy and it showed a dose of about 0.1 mGy. The higher the density and thickness of the shielding material, the better the shielding effect. In addition, the dose reduction effect for each shielding material is between 40 and 98%. Afterwards, it is deemed necessary to study the reduction of fetal doses through various shielding characteristics and methods.

Investigation of the Time Required for General Radiography (일반 방사선검사의 소요 시간 실태조사)

  • Lim, Woo-Taek;Joo, Young-Cheol;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.255-262
    • /
    • 2022
  • In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.

Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium (CT 조영제가 MR 조영제의 이완율에 미치는 영향)

  • Kwon, Soon-Yong;Kang, Chung-Hwan;Jeong, Hyeon Keum;Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

Evaluation of osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI (자기공명영상을 이용한 악관절내장증환자와 악관절증환자의 골변화에 관한 연구)

  • Cho Su-Beom;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.159-164
    • /
    • 2001
  • Purpose: To evaluate the osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI. Materials and Methods: MR images of 111 TMJs in 64 patients were analyzed to evaluate the osseous changes, 111 TMJs were divided into 6 groups according to the radiologic Stages by Schellhas and Wilkes. On MR images, we evaluate the osseous changes of articular eminence and condylar head. Results: The most frequent Stage in internal derangement of TMJ was Stage I. And 28 joints (25.2%) revealed osteoarthritis with internal derangement. When osseous change of articular eminence and condylar head occur, flattening was the most common osseous change. Sclerosis was observed in all Stages and osteophytosis of condylar head was observed in Stage II (1.8%) and III (0.9%). Out of 28 joints with osteoarthritis, 6 joints (21.4%) showed joint effusion. Conclusion: MR image revealed abnormal configuration of disk, but the detection of minimal osseous change was subtle.

  • PDF

Transcranial radiograph and magnetic resonance imaging in the evaluation of osseous changes of the temporomandibular joint (경두개방사선사진과 자기공명영상을 이용한 측두하악관절 골변화에 관한 연구)

  • Cho Su-Beom;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.99-105
    • /
    • 2002
  • Purpose: To evaluate the diagnostic accuracy of transcranial radiographs and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) in the assessment of osseous changes of the condylar head and articular eminence. Materials and Methods: Osseous changes of the TMJ were evaluated in forty-three patients. Osseous changes of the condylar head and articular eminence were observed in 41 joints and 64 joints, respectively on transcranial radiographs, and 48 joints and 59 joints, respectively on MRI. Results: The flattening, sclerosis, erosion, and osteophyte formation of the condylar heads were observed in 36.6%, 43.9%, 12.2%, and 7.3%, respectively on transcranial radiographs compared with 35.4%, 20.8%, 37.5%, and 6.3%, respectively on MRI. While, the flattening, sclerosis, and erosion of the articular eminences were observed in 26.6%, 67.2%, and 6.2%, respectively on transcranial radiographs compared with 32.2%, 59.3%, and 8.5%, respectively on MRI. Conclusion: There were no statistical differences between transcranial radiographs and MRI scans in the detection of osseous changes of the TMJ. However, MRI scans were superior to the transcranial radiographs in the detection of erosion of the condylar head (p<0.01).

  • PDF

Effects of low dose irradiation on the calcific nodule formation in MC3T3-E1 osteoblastic cell line (저선량 방사선이 MC3T3-E1 골모세포주의 석회화결절 형성에 미치는 영향)

  • Kim Kyung-A;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.137-144
    • /
    • 2004
  • Purpose: To investigate the effects of low dose irradiation on the calcium content and calcific nodule formation of the MC3T3-El osteoblastic cell line. Materials and Methods: Cells were irradiated with a single dose of 0.2, 0.4 and 0.6 Gy at a dose rate of 5.38 Gy/min using Cs-137 irradiator. After irradiation, the calcium content and calcific nodule formation were examined on the 1st, 2nd, 3rd and 4th week. Results: We did not find any significant difference of total calcium content after irradiation of 0.2, 0.4 and 0.6 Gy when compared with the unirradiated control group. There was no significant difference of total calcium content between 0.2, 0.4 and 0.6 Gy irradiated groups. We found an increased tendency of the calcific nodule formation after irradiation of 0.2, 0.4 and 0.6 Gy when compared with the unirradiated control group without significant difference of calcific nodule formation between 0.2, 0.4 and 0.6 Gy irradiated groups. Conclusion : The results showed an increased tendency of the calcific nodule formation after low dose irradiation. However, this tendency did not increase with the increase of irradiation dose.

  • PDF