• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.028 seconds

Effect of deep transfer learning with a different kind of lesion on classification performance of pre-trained model: Verification with radiolucent lesions on panoramic radiographs

  • Yoshitaka Kise;Yoshiko Ariji;Chiaki Kuwada;Motoki Fukuda;Eiichiro Ariji
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.27-34
    • /
    • 2023
  • Purpose: The aim of this study was to clarify the influence of training with a different kind of lesion on the performance of a target model. Materials and Methods: A total of 310 patients(211 men, 99 women; average age, 47.9±16.1 years) were selected and their panoramic images were used in this study. We created a source model using panoramic radiographs including mandibular radiolucent cyst-like lesions (radicular cyst, dentigerous cyst, odontogenic keratocyst, and ameloblastoma). The model was simulatively transferred and trained on images of Stafne's bone cavity. A learning model was created using a customized DetectNet built in the Digits version 5.0 (NVIDIA, Santa Clara, CA). Two machines(Machines A and B) with identical specifications were used to simulate transfer learning. A source model was created from the data consisting of ameloblastoma, odontogenic keratocyst, dentigerous cyst, and radicular cyst in Machine A. Thereafter, it was transferred to Machine B and trained on additional data of Stafne's bone cavity to create target models. To investigate the effect of the number of cases, we created several target models with different numbers of Stafne's bone cavity cases. Results: When the Stafne's bone cavity data were added to the training, both the detection and classification performances for this pathology improved. Even for lesions other than Stafne's bone cavity, the detection sensitivities tended to increase with the increase in the number of Stafne's bone cavities. Conclusion: This study showed that using different lesions for transfer learning improves the performance of the model.

Development of a Medical Radiation Simulator System for Education and Proposal of a Research Model (교육용 의료방사선 시뮬레이터 시스템 개발 및 연구 모델 제안)

  • Chang-Hwa Han;Young-Hwang Jeon;Jae-Bok Han;Chang-gi Kong;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • Due to the development of advanced technology, a lot of digital radiographic equipment has been developed, which is very helpful for accurate diagnosis and treatment, and it is very important to train personnel who have acquired professional knowledge in order to use it safely and effectively. Students are exposed to the risk of radiation exposure in radiography training using diagnostic X-ray equipment, and some educational institutions do not use X-ray equipment due to management difficulties in accordance with the Nuclear Safety Act. As a solution to this, this study developed a medical radiation simulator for education that does not generate radiation by using a vision sensor and self-developed software. Through this, educational institutions can reduce the burden of administrative implementation according to the law, and students can obtain a high level of educational effects in a healthy practice environment without radiation exposure.

Image quality-based dose optimization in pediatric cone-beam computed tomography: A pilot methodological study

  • Hak-Sun Kim;Yoon Joo Choi;Kug Jin Jeon;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.264-270
    • /
    • 2024
  • Purpose: This study aimed to propose a methodological approach for reducing the radiation dose in pediatric cone-beam computed tomography (CBCT), focusing exclusively on balancing image quality with dose optimization. Materials and Methods: The dose-area product (DAP) for exposure was reduced using copper-plate attenuation of an X-ray source. The thickness of copper (Cu) was increased from 0 to 2.2 mm, and 10 different DAP levels were used. The QUART DVT_AP phantom and pediatric radiologic dentiform were scanned under the respective DAP levels. The contrast-to-noise ratio (CNR), image homogeneity, and modulation transfer function (MTF) were analyzed using the QUART DVT_AP phantom. An expert evaluation (overall image grade, appropriateness of field of view, artifacts, noise, and resolution) was conducted using pediatric dentiform images. The critical DAP level was determined based on phantom and dentiform analysis results. Results: CNR and image homogeneity decreased as the DAP was reduced; however, there was an inflection point of image homogeneity at Cu 1.6 mm (DAP=138.00 mGy·cm2), where the value started increasing. The MTF showed constant values as the DAP decreased. The expert evaluation of overall image grades showed "no diagnostic value" for dentiform images with Cu 1.9-2.2 mm (DAP=78.00-103.33 mGy·cm2). The images with Cu 0-1.6 mm (DAP=138.00-1697.67mGy·cm2) had a "good," "moderate," or "poor but interpretable" grade. Conclusion: Reducing DAP beyond a 1.6-mm Cu thickness degraded CBCT image quality. Image homogeneity and clinical image grades indicated crucial decision points for DAP reduction in pediatric CBCT scans.

Parotid mandibular bone defect: A case report emphasizing imaging features in plain radiographs and magnetic resonance imaging

  • Hisatomi, Miki;Munhoz, Luciana;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.269-273
    • /
    • 2017
  • Mandibular bone depression, also known as Stafne bone cavity, is defined as a bone depression filled mainly with salivary gland tissue. Parotid gland bone defects are infrequently observed. We report the case of a 52-year-old male patient who underwent radiographic examinations due to temporomandibular joint dysfunction, and a radiolucent area was detected in the mandibular ramus, with a provisional diagnosis of traumatic bone cyst or parotid mandibular bone defect. The patient was then referred for magnetic resonance imaging, which demonstrated a hyperintense area eroding the mandibular ramus, which corresponded to glandular tissue. Although the defect was a benign lesion, radiolucencies in the mandibular ramus lead to concerns among professionals, because their radiographic features can resemble various intrabony neoplastic lesions, such as giant cell tumors or benign tumors of the parotid gland.

A case report of odontogenic myxoma with characteristic multilocular lesion (특징적인 다방성 소견을 보이는 치성 점액종의 증례보고)

  • Lee, Byung-Do;Lee, Wan;Paeng, Jun-Young;Son, Hyun-Jin
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.51-54
    • /
    • 2009
  • Although odontogenic myxoma (OM) has various radiographic appearances, the characteristic features of OM are the multilocular radiolucent lesion, straight bony septa along the margin forming either square or triangular spaces. We present a case of OM in a 25-year old-male patient. Multilocular radiolucent lesion on the left mandible body showed tennis racket appearance. Cone beam computed tomography (CBCT) showed straight bony septa along the margin and cortical perforation. This CBCT features would have significantly contributed to allowing a diagnosis of OM. We think that this case shows characteristic radiographic features of odontogenic myxoma.

  • PDF

Correlations between anatomical variations of the nasal cavity and ethmoidal sinuses on cone-beam computed tomography scans

  • Shokri, Abbas;Faradmal, Mohammad Javad;Hekmat, Bahareh
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.103-113
    • /
    • 2019
  • Purpose: Anatomical variations of the external nasal wall are highly important, since they play a role in obstruction or drainage of the ostiomeatal complex and ventilation and can consequently elevate the risk of pathological sinus conditions. This study aimed to assess anatomical variations of the nasal cavity and ethmoidal sinuses and their correlations on cone-beam computed tomography (CBCT) scans. Materials and Methods: This cross-sectional study evaluated CBCT scans of 250 patients, including 107 males and 143 females, to determine the prevalence of anatomical variations of the nasal cavity and ethmoidal sinuses. All images were taken using a New Tom 3G scanner. Data were analyzed using the chi-square test, Kruskal-Wallis test, and the Mann-Whitney test. Results: The most common anatomical variations were found to be nasal septal deviation (90.4%), agger nasi air cell (53.6%), superior orbital cell(47.6%), pneumatized nasal septum(40%), and Onodi air cell(37.2%). Correlations were found between nasal septal deviation and the presence of a pneumatized nasal septum, nasal spur, and Haller cell. No significant associations were noted between the age or sex of patients and the presence of anatomical variations (P>0.05). Conclusion: Radiologists and surgeons must pay close attention to the anatomical variations of the sinonasal region in the preoperative assessment to prevent perioperative complications.

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Association of Ultrasonography Features of Follicular Thyroid Carcinoma With Tumor Invasiveness and Prognosis Based on WHO Classification and TERT Promoter Mutation

  • Myoung Kyoung Kim;Hyunju Park;Young Lyun Oh;Jung Hee Shin;Tae Hyuk Kim;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.103-112
    • /
    • 2024
  • Objective: To investigate the association of ultrasound (US) features of follicular thyroid carcinoma (FTC) with tumor invasiveness and prognosis based on the World Health Organization (WHO) classification and telomerase reverse transcriptase (TERT) promoter mutations. Materials and Methods: This retrospective study included 54 surgically confirmed FTC patients with US images and TERT promoter mutations (41 females and 13 males; median age [interquartile range], 40 years [30-51 years]). The WHO classification consisted of minimally invasive (MI), encapsulated angioinvasive (EA), and widely invasive (WI) FTCs. Alternative classifications included Group 1 (MI-FTC and EA-FTC with wild type TERT), Group 2 (WI-FTC with wild type TERT), and Group 3 (EA-FTC and WI-FTC with mutant TERT). Each nodule was categorized according to the US patterns of the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and American College of Radiology-TIRADS (ACR-TIRADS). The Jonckheere-Terpstra and Cochran-Armitage tests were used for statistical analysis. Results: Among 54 patients, 29 (53.7%) had MI-FTC, 16 (29.6%) had EA-FTC, and nine (16.7%) had WI-FTC. In both the classifications, lobulation, irregular margins, and final assessment categories showed significant differences (all Ps ≤ 0.04). Furthermore, the incidences of lobulation, irregular margin, and high suspicion category tended to increase with increasing tumor invasiveness and worse prognosis (all Ps for trend ≤ 0.006). In the WHO groups, hypoechogenicity differed significantly among the groups (P = 0.01) and tended to increase in proportion as tumor invasiveness increased (P for trend = 0.02). In the alternative group, punctate echogenic foci were associated with prognosis (P = 0.03, P for trend = 0.03). Conclusion: Increasing tumor invasiveness and worsening prognosis in FTC based on the WHO classification and TERT promoter mutation results were positively correlated with US features that indicate malignant probability according to both K-TIRADS and ACR-TIRADS.

Direction of Tissue Contraction after Microwave Ablation: A Comparative Experimental Study in Ex Vivo Bovine Liver

  • Junhyok Lee;Hyunchul Rhim;Min Woo Lee;Tae Wook Kang;Kyoung Doo Song;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Objective: This study aimed to investigate the direction of tissue contraction after microwave ablation in ex vivo bovine liver models. Materials and Methods: Ablation procedures were conducted in a total of 90 sites in ex vivo bovine liver models, including the surface (n = 60) and parenchyma (n = 30), to examine the direction of contraction of the tissue in the peripheral and central regions from the microwave antenna. Three commercially available 2.45-GHz microwave systems (Emprint, Neuwave, and Surblate) were used. For surface ablation, the lengths of two overlapped square markers were measured after 2.5- and 5-minutes ablations (n = 10 ablations for each system for each ablation time). For parenchyma ablation, seven predetermined distances between the markers were measured on the cutting plane after 5- and 10-minutes ablations (n = 5 ablations for each system for each ablation time). The contraction in the radial and longitudinal directions and the sphericity index (SI) of the ablation zones were compared between the three systems using analysis of variance. Results: In the surface ablation experiment, the mean longitudinal contraction ratio and SI from a 5-minutes ablation using the Emprint, Neuwave, and Surblate systems were 28.92% and 1.04, 20.10% and 0.53, and 24.90% and 0.45, respectively (p < 0.001). A positive correlation between longitudinal contraction and SI was noted, and a similar radial contraction was observed. In the parenchyma ablation experiment, the mean longitudinal contraction ratio and SI from a 10-minutes ablation using the three pieces of equipment were 38.60% and 1.06, 32.45% and 0.61, and 28.50% and 0.50, respectively (p < 0.001). There was a significant difference in the longitudinal contraction properties, whereas there was no significant difference in the radial contraction properties. Conclusion: The degree of longitudinal contraction showed significant differences depending on the microwave ablation equipment, which may affect the SI of the ablation zone.