• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.032 seconds

Clinical assessment of various imaging systems for dental plaque scoring after the use of 3 different toothpastes

  • Simge Meseli;Sergen Ekenel;Bora Korkut;Burak Aksu;Dilek Tagtekin;Funda Yanikoglu
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.209-216
    • /
    • 2023
  • Purpose: This study was conducted to compare dental plaque scores obtained through clinical examinations and various imaging techniques, as well as to assess the effectiveness of herbal and conventional toothpastes for plaque removal. Materials and Methods: Thirty volunteers were divided into 3 groups. Each group was given a different toothpaste (from 2 herbal toothpastes and a conventional toothpaste) with which to brush their teeth for 21 days. Both initially and after brushing, dental plaque samples were collected, and plaque on the buccal surfaces of anterior teeth was scored using several imaging systems after staining with a disclosing agent. Specifically, digital dental photography, intraoral digital scanning, and FluoreCam imaging were employed to capture intraoral images. The Turesky Modified Quigley-Hein Plaque Index was used for clinical examination and image analysis. Quantitative polymerase chain reaction analyses and correlational assessments between clinical examination and imaging scores were conducted before and after toothpaste use. The Shapiro-Wilk test and Pearson correlations were utilized. Results: The lowest mean value was observed in the clinical examination without staining, while the highest was obtained using the FluoreCam method. No significant change was found in the level of any microorganism assessed following toothpaste use (P<0.05), with the exception of a decrease in S. mutans levels after using conventional toothpaste (P<0.05). Conclusion: Herbal toothpaste demonstrated plaque-removal effectiveness comparable to that of conventional toothpaste. The use of imaging methods for measuring plaque index has been suggested as a means to educate patients about plaque control and promote ongoing oral care.

Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant

  • Debora Costa Ruiz;Larissa de Oliveira Reis;Rocharles Cavalcante Fontenele;Murilo Miranda-Viana;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.289-295
    • /
    • 2024
  • Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes(enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis (P>0.05). Intra- and inter-examiner agreement ranged from fair to substantial. Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

Study of Graduate Curriculum in the Radiological Science : Problems and Suggestions (방사선학과의 대학원 교육과정에 대한 연구)

  • Ko, Seong-Jin;Kim, Hwa-Gon;Kang, Se-Sik;Park, Byeong-Rae;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.293-301
    • /
    • 2006
  • Currently, Educational program of radiological science is developed in enormous growth, our educational environments leading allied health science education program in the number of super high speed medical industry. Radiological science may be the fastest growing technologies in our medical department today. In this way, Medical industry fields converged in the daily quick, the fact that department of radiological science didn't discharged ones duties on current educational environments. The curriculum of radiological technologists that play an important part between skill and occupation's education as major and personality didn't performed one's part most effectively on current medical environments and digital radiological equipments interface. We expect improvement and suggestion to grow natural disposition as studies in the graduate of radiological science. Therefore, in this paper, current curriculum of radiological science are catched hold of trend and problems on digital radiology environments, on fact the present state of problems, for Graduate program of radiological science, graduate courses of MS and Ph.D. are suggested a reform measure of major education curriculum introduction.

  • PDF

Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example (GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법)

  • Kim, Byung-Yong;Kim, Hyung-Dong;Kim, Sung-Jin;Oh, Se-An;Kang, Jung-Gu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

  • Salineiro, Fernanda Cristina Sales;Gialain, Ivan Onone;Kobayashi-Velasco, Solange;Pannuti, Claudio Mendes;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Materials and Methods: Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. Results: The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Conclusion: Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

The Effect of Vision Training on Exophoria and Intermittent Extropia Using MYSTERY CIRCLE System (MYSTERY CIRCLE 시스템을 이용한 폭주부족형 사위 및 간헐성 사시 환자의 시기능 훈련 효과 연구)

  • Lee, Chang-Seon;Kim, Kun-Kyu;Jeon, Young-Ki;Kim, Kong-Ki;Choi, Chul-Hee;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effect of vision training using MYSTERY CIRCLE system on patients with exophoria and intermittent extropia. Mehtods: The vision training observation group consists of 26 clients who had exophoria (n=18) and intermittent extropia (n=8) without opthalmic diseases or vertical phoria. Our clients took each vision training once a week for eight weeks and were investigated for the symptoms changes of binocular vision. Results: According to the results, MISTERY CIRCLE vision training methods improved the binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses showed fusion rate changes. Conclusions: The study proved that MISTERY CIRCLE vision training system for patients with binocular vision was effective for the improvement of the binocular vision symptoms of these patients.

Usefulness of pelvic ultrasonography for the diagnosis of central precocious puberty in girls

  • Yu, Jung;Shin, Ha Young;Lee, Sun Hee;Kim, You Sung;Kim, Jae Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.294-300
    • /
    • 2015
  • Purpose: It is difficult to differentiate between central precocious puberty (CPP) and premature thelarche (PT) in girls. The aim of this study was to investigate the diagnostic usefulness of pelvic ultrasonography to distinguish between CPP and PT in girls with early breast development. Methods: This study included girls with early breast development who visited the clinic between January 2012 and December 2013. Clinical, laboratory, and pelvic ultrasonographic data were evaluated. CPP and PT were confirmed using the gonadotropin-releasing hormone stimulation test. Results: A total of 248 girls aged 7-8 years were included, among whom 186 (75.0%) had CPP and 62 (25.0%) had PT. The uterine length, transverse diameter, fundus, volume, and cross-sectional area were significantly larger in the CPP group (uterine length, $2.45{\pm}0.50cm$ vs. $2.63{\pm}0.49cm$, P=0.015; uterine volume, $0.95{\pm}0.62cm^3$ vs. $1.35{\pm}0.76cm^3$, P<0.001). However, there were no differences in the fundus/cervix ratio and ovarian measurements. In receiver operating characteristic analysis, a uterine volume of at least $1.07cm^3$ was the most predictive parameter for CPP with an area under the curve of 0.670 (95% confidence interval, 0.593-0.747). Conclusion: Uterine measurements by pelvic ultrasonography in girls with early pubertal development were significantly larger in the CPP group. However, the diagnostic value of ultrasonographic parameters was not high because of a considerable overlap of values between the two groups. Therefore, pelvic ultrasonography in combination with clinical and laboratory tests may be useful to distinguish between CPP and PT in girls.

Three-dimensional soft tissue analysis for the evaluation of facial asymmetry in normal occlusion individuals

  • Hwang, Hyeon-Shik;Yuan, Donghui;Jeong, Kweon-Heui;Uhm, Gi-Soo;Cho, Jin-Hyoung;Yoon, Sook-Ja
    • The korean journal of orthodontics
    • /
    • v.42 no.2
    • /
    • pp.56-63
    • /
    • 2012
  • Objective: To identify the right and left difference of the facial soft tissue landmarks three-dimensionally from the subjects of normal occlusion individuals. Materials and Methods: Cone-beam computed tomography (CT) scans were obtained in 48 normal occlusion adults (24 men, 24 women), and reconstructed into 3-dimensional (3D) models by using a 3D image soft ware. 3D position of 27 soft tissue landmarks, 9 midline and 9 pairs of bilateral landmarks, were identified in 3D coordination system, and their right and left differences were calculated and analyzed. Results: The right and left difference values derived from the study ranged from 0.6 to 4.6 mm indicating a high variability according to the landmarks. In general, the values showed a tendency to increase according to the lower and lateral positioning of the landmarks in the face. Overall differences were determined not only by transverse differences but also by sagittal and vertical differences, indicating that 3D evaluation would be essential in the facial soft tissue analysis. Conclusions: Means and standard deviations of the right and left difference of facial soft tissue landmarks derived from this study can be used as the diagnostic standard values for the evaluation of facial asymmetry.

The association between radiographic embrasure morphology and interdental papilla reconstruction using injectable hyaluronic acid gel

  • Lee, Won-Pyo;Seo, Yo-Seob;Kim, Hee-Jung;Yu, Sang-Joun;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.277-287
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the clinical efficacy of enhancing deficient interdental papilla with hyaluronic acid gel injection by assessing the radiographic anatomical factors affecting the reconstruction of the interdental papilla. Methods: Fifty-seven treated sites from 13 patients (6 males and 7 females) were included. Patients had papillary deficiency in the upper anterior area. Prior to treatment, photographic and periapical radiographic standardization devices were designed for each patient. A 30-gauge needle was used with an injection-assistance device to inject a hyaluronic acid gel to the involved papilla. This treatment was repeated up to 5 times every 3 weeks. Patients were followed up for 6 months after the initial gel application. Clinical photographic measurements of the black triangle area (BTA), height (BTH), and width (BTW) and periapical radiographic measurements of the contact point and the bone crest (CP-BC) and the interproximal distance between roots (IDR) were undertaken using computer software. The interdental papilla reconstruction rate (IPRR) was calculated to determine the percentage change of BTA between the initial and final examination and the association between radiographic factors and the reconstruction of the interdental papilla by means of injectable hyaluronic acid gel were evaluated. Results: All sites showed improvement between treatment examinations. Thirty-six sites had complete interdental papilla reconstruction and 21 sites showed improvement ranging from 19% to 96%. The CP-BC correlated with the IPRR. More specifically, when the CP-BC reached 6 mm, virtually complete interdental papilla reconstruction via injectable hyaluronic acid gel was achieved. Conclusions: These results suggest that the CP-BC is closely related to the efficacy of hyaluronic acid gel injection for interdental papilla reconstruction.