Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Assessment of Radiation Shielding Ability of Printing Materials Using 3D Printing Technology: FDM 3D Printing Technology (3D 프린팅 기술을 이용한 원료에 대한 방사선 차폐능 평가: FDM 방식의 3D 프린팅 기술을 중심으로)

  • Lee, Hongyeon;Kim, Donghyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.909-917
    • /
    • 2018
  • 3D printing technology is expected to be an innovative technology of the manufacturing industry during the 4th industrial revolution, and it is being used in various fields including biotechnology and medical field. In this study, we verified the printing materials through Monte Carlo simulation to evaluate the radiation shielding ability of the raw material using this 3D printing technology. In this paper, the printing materials were selected from the raw materials available in a general-purpose FDM-based 3D printer. Simulation of the ICRU phantom and the shielding system was carried out to evaluate the shielding effect by evaluating the particle fluence according to the type and energy of radiation. As a result, the shielding effect tended to decrease gradually with increasing energy in the case of photon beam, and the shielding effect of TPU, PLA, PVA, Nylon and ABS gradually decreased in order of materials. In the case of the neutron beam, the neutron intensity increases at a low thickness of 5 ~ 10 mm. However, the effective shielding effect is shown above a certain thickness. The shielding effect of printing material is gradually increased in the order of Nylon, PVA, ABS, PLA and TPU Respectively.

Evaluation of Absorbed Dose according to the Use of Bolus in Opposite Breast during Radiation Therapy of Breast Cancer using VMAT (VMAT를 이용한 유방암 방사선치료 시 반대편 유방의 Bolus 사용에 따른 흡수선량 평가)

  • Kim, Jong-Bo;Shin, Sang-Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.763-768
    • /
    • 2018
  • Although the development of radiation therapy techniques has made the treatment more precise, exposure by radiation is unavoidable beyond the treatment site. In this study, we wanted to evaluate the absorbed dose according to the thickness of the bolus on the opposite side of the treatment in radiation treatment for breast cancer and to analyze the effect of dose reduction. An experiment was conducted on Rando phantom using VMAT treatment methods. Five points of A, B, C, D, and E were selected for the breast opposite the treatment, and when the dosimeters of 5, 10, 15, and 20 mm were used. The highest absorbed dose at point D closest to the treatment point was measured and lowest at point B furthest from the treatment point. The mean absorbed dose was 8.61 cGy When the bolus is not used and 8.10, 7.94, 8.06, and 8.10 cGy Depending on the thickness of the bolus. In this study, bolus was intended to be used to analyze the dose-reducing effects of breasts on the other side of the treatment. The results of the study showed the effect of dose reduction and the appropriate bolus thickness should be set up to reduce the dose in normal tissues.

Design of Simple Shielding Handkerchief to Protect the Passenger's Thyroid (비행기 이용승객의 갑상선 차폐를 위한 간편한 손수건 고안)

  • Jung, Hongmoon;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.87-93
    • /
    • 2019
  • Recently, the number of passengers using airplanes is rapidly increasing due to the increase of overseas travelers. Therefore, the probability of exposure to natural radiation due to altitude is increasing due to the increase in flight time. Cosmic-ray penetrates the Earth's magnetic field belt Van Allen, which is located at an altitude of 400 km to 1200 km. Most cosmic rays are blocked at Van Allen belt. However, cosmic-ray could be not completely blocked, and a small amount of cosmic-ray affects the earth. In general, if the altitude was increased by 100m, the natural exposure dose increased by 0.03 mSv on the Earth. In this study, I tried to minimize the exposure to natural radiation in airplanes when boarding airplanes. Especially, I was aimed to minimize radiation exposure by protecting the highly sensitive thyroid gland among human organs. According to the results of the study, the designed shielding handkerchief was able to shield cosmic natural radiation dose by more than 70%. In conclusion, the application of the shielding handkerchief made in this study can be effectively shield natural radiation.

Radio-sensitivity of Human Colorectal Cancer Cell is Regulated by Potassium Cyanate (Potassium cyanate에 의해 조절되는 사람 대장암 세포의 방사선 감수성 변화)

  • Yang, Eun Ju;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.125-132
    • /
    • 2019
  • Potassium cyanate (KCN) is an inorganic reagent and can induce the post-translation carbamylation of proteins. The carbamylated reaction in the body is involved in cell death in various diseases. According the results in our previous study, KCN enhances the radiosensitivity of human colorectal cancer cell line, HCT 116 cells. However, it was not enough to confirm the mechanism that KCN works in these cells. To determinated the mechanisms of KCN in the cells with increased radiosensitivity, HCT 116 cells were treated KCN with low-dose gamma-radiation. And then, we examined alteration of the cell cycle, cell proliferation, cytokine level and the activation of cell signaling protein. As a result, cell cycle arrest and cell death were induced by the activation of caspase-3 and PARP in the irradiated cells with KCN treatment. These changes of the irradiated cell with KCN treatment were induced by the release of $TNF-{\alpha}$ via $NF-{\kappa}B$ activation. In conclusions, enhanced radio-sensitivity mediated by KCN induced cell death and it occurs by $NF-{\kappa}B$-dependent $TNF-{\alpha}$ production.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Study of Appropriate Increment during VRT Rendering before Musculoskeletal Surgery (근골격계 수술전 VRT Rendering시 적절한 increment에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.675-681
    • /
    • 2019
  • The purpose of this study was to investigate the effect of increasing the amount of 3D volume imaging on the hand, knee, and foot human phantom in CT, After analyzing the data, three - dimensional volumetric images were implemented using MMWP program to evaluate reproducibility. First, the data amount of three human phantoms according to each increment was analyzed. Secondly, the reproducibility evaluation and the measured length were compared. As a result of analyzing the amount of image data for each phantom according to the increment, it was confirmed that the amount of data is reduced to about 1/10 when the increment is set to 1.0 mm as compared with the case where the increment is set to 0.1 mm. In the evaluation of the feasibility, gap was generated from 0.7mm for hand phantom, 0.6mm for knee phantom and foot phantom, and it was confirmed that even when the actual phantom and actual length were compared, the length was much different and the implementation was lowered. As the increment is closer to 1.0mm, the number of images is small and the 3D implementation time is small. Therefore, it is best to determine the increase before the gap of the image is generated and to apply the Increment for preoperative diagnosis. We hope that this study will be an indicator of the accurate increment setting when implementing 3D image through VRT Rendering after CT scan.

Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT (소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가)

  • Park, Ki Seok;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.683-689
    • /
    • 2019
  • We are trying to evaluate usefulness of Wide Coverage Volume Axial Mode by comparing and analyzing for exposure doses to patients and video quality extracted from two materials. First material is a computer tomography scanning of paediatric cardiac made by using High Pitch Mode, which is designed for diagnosing Congenital cardiac diseases. Second material is computer tomography scanning of paediatric cardiac made by using Wide Coverage Volume Axial Mode. When we did computer tomography scanning of paediatric cardiac, we used High Pitch Mode and Wide Coverage Volume Axial Mode to 50 patients of each, overall 100 patients. Also, we compared exposure doses to patients using videos got from each protocol. Then we compared video quality by calculating SNR and CNR by setting ROI of each. Not only exposure doses to patients were reduced by 13.07 %, but also SNR and CNR were improved when testing used Wide Coverage Volume Axial Mode rather than using High Pitch Mode. Wide Coverage Volume Axial Mode reduced testing time by using high-speed scanner. Furthermore, we can find out that Wide Coverage Volume Axial Mode is an useful method through improving video quality and reducing exposure doses to patients than using High Pitch Mode from ASiR-V, which is low-dose technology.

Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination (Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구)

  • Lee, Ju Ryeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • The purpose of this study was to investigate whether there is a difference in image quality before and after reducing the amount of contrast medium in cerebral hemorrhagic patients who periodically follow up CT, and after reducing the amount of contrast medium, the image before and after reduction was examined, and the image quality was assessed by setting ROI at each vessel location using MMWP program. First Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA and Basilar Artery each got an ROI. Second, the mean and standard deviation values for the ROI were obtained. Third, SNR and CNR were obtained through the average and standard deviation values obtained. T-test statistics show that the SNR and CNR values obtained show that the result values for SNR are Rt.CCA 0.765, Ltd.CCA 0.871, Rt.MCA 0.343 LT.MCA 0.235, Basilar alternative 0.916, result value for CNR Rt.CCA 0.088, Ltd.CCA 0.069, Rt.MCA 0.818, Let's...MCA 0.579 and Basilar Artery 0.878. The results obtained through the obtained SNR and CNR values showed no difference in the quality of the images before and after reducing contrast medium. Therefore, we hope that this study will be an indicator that reduces the burden on contrast agents on patients who do CT examinations periodically.