• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.031 seconds

Cone-beam computed tomographic imaging of central giant cell granuloma: A comprehensive review

  • Tahmasbi-Arashlow, Mehrnaz;Patel, Paras B.;Nair, Madhu K.;Liang, Hui;Cheng, Yi-Shing Lisa
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.123-131
    • /
    • 2022
  • Purpose: The aim of this study was to characterize the cone-beam computed tomographic (CBCT) imaging features of central giant cell granuloma (CGCG) of the jawbone. Materials and Methods: This study retrospectively reviewed 26 CBCT studies of histologically proven cases of CGCG during a period of 20 years, from 1999 to 2019. Patients' demographic data were recorded, and radiographic features were assessed (location, border, cortication, appearance of the internal structure, locularity, septation, expansion, cortical perforation, effects on surrounding tissue, whether the lesion crossed the midline, and lesion volume). Results: In this study, CGCGs were seen almost twice as often in the mandible than in the maxilla, and 64.7% of mandibular lesions involved the anterior region. Only 26.9% of lesions crossed the midline, a feature that was considered characteristic of CGCG. Furthermore, 65.4% of lesions were unilocular and 34.6% were multilocular. The correlation between a lesion's size and its locularity was statistically significant, and larger lesions showed a multilocular appearance. The mean volume of multilocular lesions was greater than that of unilocular lesions. Conclusion: CGCGs showed variable radiographic features on CBCT, and this imaging modality is highly effective at demonstrating the radiographic spectrum and lesional extent of CGCGs in the jawbone.

An unusual presentation of osteoblastoma of the maxilla: A case report

  • Lim, Joonbum;Hinchy, Nicole;Odingo, Nora;Colosi, Dan;Mahdian, Mina
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.455-460
    • /
    • 2021
  • This report presents a rare case of maxillary osteoblastoma in a 17-year-old female. The patient presented with dull pain and facial asymmetry inferior to the left zygoma. An intraoral examination found a painless swelling on the buccal gingival tissue in the left posterior maxilla. Panoramic radiographs and multidetector computed tomographic images revealed an ill-defined, non-corticated, mixed attenuating entity of osseous density located within the left posterior maxilla apical to the left maxillary molars. The entity exhibited a heterogeneous internal structure with a fine granular appearance, and the periphery showed a partial hypo-attenuating rim along the antero-medial aspect. Expansion of the left posterior maxilla accompanied with displacement of the left maxillary sinus floor was noted. External root resorption of the first and second molars was noted, as well as postero-superior displacement of the third molar. The histopathologic diagnosis of the biopsy was osteoblastoma. Complete excision of the tumor was performed.

Educational Effects of Self-directed Learning Method Using 3D Printing Products on Radiological Science Students (3D 프린팅 구조물을 이용한 자기주도 학습방법이 방사선학과 학생들에 미치는 교육 효과)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.45-51
    • /
    • 2020
  • The purpose of this study was to analyze the educational effect of self-directed learning method using 3D printed anatomy on radiological science students. The subjects were 32 students (20 males and 12 females) in the second year of radiological science at university. They were divided two groups as a non-active student group and an active student group. A learning method was self-directed learning using 3D printed anatomical structures, and the effects of quantitative learning improvement were evaluated before and after the learning. The qualitative evaluation of the students was analyzed on the Likert's 5-point scale for the interest, satisfaction, and learning effects (memorization convenience of anatomy name, radiography Interpret ability, understanding on bones structure, and X-ray projection technique). As a result, the enhancement of learning improved 65.4% on average, and all students got scored high on all variables. Especially non-active student groups showed higher correlation coefficients in all variables except interest and radiography interpret than active student groups. These results might suggest that self-directed learning using 3D printed anatomical structures could have a positive educational effect on radiological science students.

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Comparison between division of health science and dental hygiene in Korea (국내 의료보건계열 신설동향과 치위생(학)과 추이에 관한 연구)

  • Yang, Song-Yi;Kim, Sook-Hyang;Oh, Sang-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.419-430
    • /
    • 2012
  • Objectives : This review suggests prospect of educational institutions through research on the establishment trend of Korean dental hygiene programs by comparison with health science programs, analysis based on location and year. Methods : For the research, 78 dental hygiene programs, 11 dental colleges, 144 nursing programs, 41 medicine programs, 38 radiology programs, 49 optometry programs, 39 biomedical laboratory science programs, 65 physical therapy programs, 48 occupational therapy programs were analyzed using SPSS 12.0v. The result is as follows. Results : Establishment trend of dentistry-related programs and dental hygiene programs is twice as high as nursing programs and medicine-related programs. Number of 3-years dental hygiene programs is twice as high as 4-years dental hygiene programs. Entrance quota of 3-years dental hygiene programs is four time higher than 4-years programs. On regional basis, number of dental hygiene programs is the highest in Gyeonggi-do by 9 while it is the lowest in Incheon-si and Jeju-do by 1. Number of students in dental hygiene programs is the highest in Gyeonggi-do by 2,514. Establishment of dental hygiene programs showed the biggest increasing trend in Gyeonggi-do and Jeju-do from 1995 to 1999; and in Gangwon-do, Chungcheongbuk-do, Chungcheongnam-do, Gyeongsangbuk-do, Gyeongsangnam-do, Jeollabuk-do, Jeollanam-do from 2005 to 2010. Conclusions : Assurance of legal rights in the workplace and improvement of educational environment should take prudence over establishment of dental hygiene programs in order to develop professionalism among students in dental hygiene.

Suitable Food Textures for Videofluoroscopic Studies of Swallowing in Esophageal Cancer Cases to Prevent Aspiration Pneumonia

  • Sonoi, Mika;Kayashita, Jun;Yamagata, Yoshie;Tanimoto, Keiji;Miyamoto, Ken-ichi;Sakurama, Kazufumi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3259-3263
    • /
    • 2016
  • Aims: To determine suitable food textures for videofluoroscopic study of swallowing (VFSS), in order to predict and prevent subsequent aspiration pneumonia in esophageal cancer patients with dysphagia after surgery. Materials and Methods: We evaluated 45 hospitalized esophageal cancer patients who underwent surgery between January 2012 and December 2013. The control group consisted of 43 patients treatmed from January 2010 until December 2011 and were not examined by VFSS. Test foods, which were presented in order of increasing thickness, included thin barium sulfate (Ba) liquid (3 or 10 ml), slightly thickened Ba liquid (3 or 10 ml), a spoonful of Ba jelly, and a spoonful of Ba puree. Results: Patients could most safely swallow puree, followed by jelly. The 3-mL samples of both the thin and thick liquids put patients at risk for aspiration pneumonia, with incidence rates of 13% and 11%, respectively. While 64.4% of patients could swallow all test foods and liquids safely, 35.6% were at risk for aspiration pneumonia when swallowing liquids. Even though >30% of patients were at risk, only 1 (2.2%) in the VFSS group developed aspiration pneumonia, which occurred at the time of admission. Following VFSS, no incidence of aspiration pneumonia was observed. However, aspiration pneumonia occurred in 4 (9.3%) control patients during hospitalization. Conclusions: Postoperative esophageal cancer patients were more likely to aspirate any kind of liquid than solid foods, such as jellies. VFSS is very useful in determining suitable food textures for postoperative esophageal cancer patients.

Periodontal regeneration capacity of equine particulate bone in canine alveolar bone defects

  • Kim, Tae-Il;Chung, Chong-Pyoung;Heo, Min-Suk;Park, Yoon-Jeong;Rhee, Sang-Hoon
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.220-226
    • /
    • 2010
  • Purpose: This study was performed to evaluate the periodontal wound healing effect of particulate equine bone mineral on canine alveolar bone defects. Methods: Twelve adult male beagle dogs were used as study subjects. The mandibular second and fourth premolars were extracted prior to the experimental surgery, and the extraction sites were allowed to heal for 8 weeks. After periodontal probing, two-walled defects were created at the mesial and distal sides of the mandibular third premolars bilaterally, and the defects were filled with equine particulate bone with collagen membrane or bovine particulate bone with collagen membrane, or collagen membrane alone. The defects without any treatment served as negative controls. After probing depth measurement, animals were sacrificed at 10, 16, and 24 post-surgery weeks for micro-computed tomographic and histomorphometric analysis. Results: The equine particulate bone-inserted group showed significantly decreased values of probing depth and first bone contact compared to the negative control and collagen membrane alone groups at weeks 10, 16, and 24 (P<0.05). There were no significant differences in the new cementum length, newly-formed bone area, or newly-formed bone volume between equine particulate bone- and bovine particulate bone-inserted groups, both of which showed significantly increased values compared to the negative control and collagen membrane alone groups (P<0.05). Conclusions: Equine particulate bone showed significant differences in probing depth, first bone contact, new cementum length, newly formed bone area, and bone volume fraction values when compared to the negative control and collagen membrane alone groups. There were no significant differences between equine and bovine particulate bone substitutes in these parameters; therefore, we can conclude that equine particulate bone is equivalent to bovine bone for periodontal regeneration.

Comparison Study of Lesion Localization in Patients with Primary and Secondary Hyperparathyroidism using Double-Phase Tc-99m Sestamibi Scintigraphy (일차성 및 이차성 부갑상선기능항진증 환자에서 Double-Phase Tc-99m Sestamibi 스캔에 의한 병변의 국소화에 관한 비교)

  • Jeon, Tae-Joo;Lee, Jong-Doo;Rhyu, Young-Hoon;Park, Jung-Soo;Jang, Hang-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.368-380
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). Materials and Methods: We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/female=5/22, age: $49.1{\pm}10.8$). Results: Eighteen lesions of primary HPT consisted of 13 adenomas and S hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.8% (10/17), 83.3% (10/12), 83.3% (10/12), 75.9% (22/29), and 37.5% (15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75% (12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Conclusion: Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits routine use of it for this disease.

  • PDF

Annual Change in Pulmonary Function and Clinical Characteristics of Combined Pulmonary Fibrosis and Emphysema and Idiopathic Pulmonary Fibrosis: Over a 3-Year Follow-up

  • Kim, Yu Jin;Shin, Seong Hyun;Park, Jeong-Woong;Kyung, Sun Young;Kang, Shin Myung;Lee, Sang-Pyo;Sung, Yon Mi;Kim, Yoon Kyung;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.1
    • /
    • pp.18-23
    • /
    • 2014
  • Background: Combined pulmonary fibrosis and emphysema (CPFE) have different pulmonary function tests (PFTs) and outcomes than idiopathic pulmonary fibrosis (IPF). The intention of this study was to identify unknown differences between CPFE and IPF by a retrospective comparison of clinical data including baseline and annual changes in pulmonary function, comorbidities, laboratory findings, clinical characteristics and cause of hospitalization. Methods: This study retrospectively enrolled patients with CPFE and IPF who had undergone PFTs once or several times per year during a follow-up period of three years. Baseline clinical characteristics and the annual changes in the pulmonary function during the follow-up period were compared between 26 with CPFE and 42 patients with IPF. Results: The baseline ratio of forced expiratory volume in one second to forced vital capacity ($FEV_1$/FVC%) in patients with CPFE was lower than that in patients with IPF ($78.6{\pm}1.7$ vs. $82.9{\pm}1.1$, p=0.041). The annual decrease in $FEV_1$/FVC in the CPFE was significantly higher than in the IPF. The annual decreases in diffusion capacity of carbon monoxide and FVC showed no significant differences between the two groups. The symptom durations of cough and sputum were in the CPFE significantly lower than in the IPF. The serum erythrocyte sedimentation rate level at the acute stage was significantly higher than in the IPF. There were no significant differences in the hospitalization rate and pneumonia was the most common cause of hospitalization in both study groups. Conclusion: The annual decrease of $FEV_1$/FVC was in patients with CPFE significantly higher than in the patients with IPF.

CBCT-based assessment of root canal treatment using micro-CT reference images

  • Lamira, Alessando;Mazzi-Chaves, Jardel Francisco;Nicolielo, Laura Ferreira Pinheiro;Leoni, Graziela Bianchi;Silva-Sousa, Alice Correa;Silva-Sousa, Yara Terezinha Correa;Pauwels, Ruben;Buls, Nico;Jacobs, Reinhilde;Sousa-Neto, Manoel Damiao
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.245-258
    • /
    • 2022
  • Purpose: This study compared the root canal anatomy between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) images before and after biomechanical preparation and root canal filling. Materials and Methods: Isthmus-containing mesial roots of mandibular molars(n=14) were scanned by micro-CT and 3 CBCT devices: 3D Accuitomo 170 (ACC), NewTom 5G (N5G) and NewTom VGi evo (NEVO). Two calibrated observers evaluated the images for 2-dimensional quantitative parameters, the presence of debris or root perforation, and filling quality in the root canal and isthmus. The kappa coefficient, analysis of variance, and the Tukey test were used for statistical analyses(α=5%). Results: Substantial intra-observer agreement (κ=0.63) was found between micro-CT and ACC, N5G, and NEVO. Debris detection was difficult using ACC (42.9%), N5G (40.0%), and NEVO (40%), with no agreement between micro-CT and ACC, N5G, and NEVO (0.05<κ<0.12). After biomechanical preparation, 2.4%-4.8% of CBCT images showed root perforation that was absent on micro-CT. The 2D parameters showed satisfactory reproducibility between micro-CT and ACC, N5G, and NEVO (intraclass correlation coefficient: 0.60-0.73). Partially filled isthmuses were observed in 2.9% of the ACC images, 8.8% of the N5G and NEVO images, and 26.5% of the micro-CT images, with no agreement between micro-CT and ACC, and poor agreement between micro-CT and N5G and NEVO. Excellent agreement was found for area, perimeter, and the major and minor diameters, while the roundness measures were satisfactory. Conclusion: CBCT images aided in isthmus detection and classification, but did not allow their classification after biomechanical preparation and root canal filling.