• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.028 seconds

Evaluation of Dose and Image Quality of Lens according to Baseline during Brain CT Scan (두부 전산화단층촬영 시 기준선에 따른 수정체 선량과 화질 평가)

  • Kim, Kyu-Hyung;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.699-704
    • /
    • 2019
  • It is important to minimize the exposure dose during an examination and obtain good quality images at the same time. This study compared the beam harding effect according to the baseline superior orbito meatal line(SOML), orbito meatal line(OML), inferior orbito metal line(OML) and measured the exposure dose of the lens, especially in brain CT examinations, which generally apply to head diease patients. The beam harding effect assessment of each image along the baseline was performed quantitatively using the Image J program, and the exposure dose of the lens was detected by OSLDs and compared. As a result, As a result, when the SOML was used as the reference line, the dose of the lens was decreased by 85.08% at 80 kV and by 79.7% at 80 kV, compared to when IOML was used as the baseline. If the gantry angle at brain CT was parallel scan to SOML, there were no significant differences in the exposure to the lens and between the OML and IOML. Therefore, this study has shown that it is efficient to have a parallel scan on SOML as a protocol during Brain CT examinations.

Satisfaction and Completion Status according to Online Continuing Education for Radiological Technologist: Focusing on Busan and Ulsan Areas (방사선사 비대면 온라인 보수교육 실태에 따른 만족도 및 이수현황: 부산, 울산지역을 중심으로)

  • Yang, Sung-Hee;Yun, Youngwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.219-227
    • /
    • 2021
  • This study examines the status of non-face-to-face online continuing education for radiological technologist working at medical institutions in a region, their satisfaction, and completion status, and provides basic data on the design and operation of continuing education predicted after the post-coronavirus. It was implemented to do. From January 5, 2021 to January 31, 2021, 255 radiological technologist license holders who completed online continuing education in 2020 were targeted. Satisfaction with online continuing education was higher as the age, male radiological technologist, and job title increased after obtaining a license. As for the status of completion of continuing education, the higher the age, the higher the percentage of regular members belonging to the branch, the more moderate the cost of continuing education of medical institutions was guaranteed, and the more the completion of the continuing education license and the recognition of legal restrictions. Based on the results of this study, in order to increase the satisfaction and completion of continuing education, it is necessary to develop various educational programs and contents according to age in preparation for the rapidly changing medical environment, and it is necessary to identify and provide members' needs.

Optimal Ambient Illumination Study for Soft-Copy Ultrasound Images (소프트 카피 초음파 이미지를 보기 위한 최적의 주변광 조도 연구)

  • An, Hyun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.209-216
    • /
    • 2019
  • The purpose of this study was to suggest the optimum ambient illumination level for proper visualization in image inspection and reading on CRT and LCD monitors used for ultrasound and reading. The evaluators were divided into 4 groups: 20 (Ultra-sonographer: 20 groups (4 groups: ultra-sonographer, 1-5 years, 5 ultra-sonographers, 6 to 10 years, 5 ultra-sonographers, 11 to 15 years, The subjects were 32 questions. The evaluation method was image evaluation of ultrasonic soft copy images for 30 seconds per 10, 25, 100Lux ambient illumination. The evaluation results were evaluated as 6 points (Normal = Definitely no lesion), 2 points = possibly not a lesion, 3 points = probably not a lesion, 4 points = possibly a lesion, 5 points = probably a lesion, 6 points = Definitely a lesion). In this study, the results of ROC analysis according to ambient light illumination reading softcopy images used for lesion detection of all ultrasound images showed the highest sensitivity, specificity, and AUC results at 10Lux. It was found that optimal use of 10Lux for ambient light illumination would provide optimal detection of lesions in ultrasound soft copy images. Based on the future research data, it will be presented as basic data for designing ambient light brightness of ultrasound imaging laboratory and reading room.

Clinical Usefulness of Ultrasonography in the Diagnosis of Fatty Liver (지방간 진단에 있어 초음파 검사의 임상적 유용성 연구)

  • An, Hyun;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.349-357
    • /
    • 2019
  • The purpose of this study was to evaluate the clinical significance of ultrasonographic classification of fatty liver in three grades. From June 2018 to April 2019, 1047 patients (818 males and 229 females) diagnosed as fatty liver among 3607 patients who underwent abdominal ultrasonography at Busan screening center. Ultrasonography was classified into three grades: Grade I (mild fatty liver), Grade II (moderate fatty liver), and Grade III (severe fatty liver) according to the degree of parenchyma texture, acoustic attenuation, Obesity index, hematological test, and metabolic syndrome. The average age of men in each sex increased with the increase of the fatty liver. Body mass index (BMI) and waist circumference were significantly increased in both men and women (p=.000). hematological analysis showed that AST, ALT, ${\gamma}-GTP$, TG, fasting blood sugar, and glycated hemoglobin were significantly different from each other (p<.05). In women, ALT, ${\gamma}-GTP$ and TG showed a significant difference with increasing fatty liver (p<.05). The prevalence of metabolic syndrome was significantly increased in both sexes as the grade of fatty liver increased (p=.000). Based on the results of this study, it is suggested that the use of ultrasound - guided fatty liver according to severity may be useful for the treatment and follow - up of fatty liver if the liver grade is divided in consideration of hematological variables and metabolic syndrome.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Evaluation of Image Usability by SEMAC Turbo Factor Change using Susceptibility Artifact Reduction (Susceptibility Artifact를 감소시키는 SEMAC 사용 시 Turbo Factor 변화에 따른 영상의 유용성 평가)

  • Choi, Young-Jae;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • The study analyzes Non SEMAC and SEMAC to reduce susceptibility artifacts that may occur when performing magnetic resonance imaging(MRI) of metal patients. The Foot and Ankle Phantom was used as the experimental tool and the 3.8 cm general screw was used to make the magnetic susceptibility artifact. The experimental equipment was used 3.0T Magnetom Skyra and the area was measured with the 17th image where the signal off is the most noticeable in the obtained image. Statistical analysis was performed using the SPSS(Ver.25) program and the significance was assessed by the Wilcoxon Signed Rank Test. As a result, the area of Non SEMAC which is the lowest signal was $289.53{\pm}23.07197mm$. When the Turbo Factor was changed to 3, 4, and 5 after SEMAC use, it decreased to $125.02{\pm}7.45875mm$, $120.96{\pm}12.01704mm$ and $108.79{\pm}16.53498mm$, respectively. In conclusion, this study demonstrates that Using SEMAC with Turbo Factor effectively reduces the susceptibility artifacts.

Analysis of the Correlation Between Ultrasonography Diagnosis Fatty Liver Grade and Hyperlipidemia and Obesity Indicators by Age Groups (연령대별 초음파 진단 지방간 등급과 고지혈증 및 비만 지표 간의 상관관계 분석)

  • Hyeon, Sang-Yeon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.863-870
    • /
    • 2020
  • The purpose of this study was to analyze the correlation between the grade of fatty liver diagnosed by ultrasonography and hyperlipidemia and obesity indicators by age groups. A total of 1,470 patients of various sex and age groups were examined by abdominal ultrasonography at the H Center in Chungbuk. The patients were classified as normal and fatty liver by age groups (below twenty, the thirties, forty, fifties, and over sixties). The grade of fatty liver was classified in detail as Grade 1 (mild fatty liver), Grade 2 (moderate fatty liver), Grade 3 (severe fatty liver). We selected indicators of hyperlipidemia as total cholesterol, triglyceride, low-density lipoprotein cholesterol, and high-density lipoprotein cholesterol. The obesity indicators were height, weight, body mass index, and waist circumference. The demographical descriptive statistic analysis and frequency analysis by age groups were performed. The difference of average and correlation between hyperlipidemia and obesity indicators were analyzed. As a result, patients over 60 have fatty liver regardless of sex. there was a difference between triglyceride, high-density lipoprotein cholesterol, weight, body mass index, and waistline for all age groups. The degree of fatty liver was highly correlated with waist size and body mass index for all age groups.

A Scope of Work of Radiological Technologists for Ultrasound Examinations (초음파검사에 대한 방사선사 업무범위의 법적 고찰)

  • Lim, Chang Seon;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.481-490
    • /
    • 2021
  • There is no qualification system for sonographers in Korea. But the MEDICAL SERVICE TECHNOLOGISTS, ETC. ACT stipulates that radiological technologists can handle ultrasound equipment. However, there is controversy about the scope of the work allowed for radiological technologists to perform ultrasound examinations. Accordingly, the authoritative interpretation of the Ministry of Health and Welfare of Korea, the adjudication of administrative judgment, and the judgment of the courts were analyzed. As a result, the authoritative interpretation expresses that when a radiological technologist performs an ultrasound examination, a diagnosis and specific guidance should be made in real time while the doctor simultaneously watches the radiological technologist's images. In the adjudication of administrative judgment, it was decided that the handling of ultrasound-related equipment was the work of the radiological technologist. The court ruled that it was illegal for a radiological technologist to make a medical judgment on ultrasound examination. In the United States, Canada, etc., the sonographer independently conducts ultrasound examination according to the doctor's prescription, prepares a summary of what they saw and this is passed on to the doctor. Therefore, in Korea, there is a need for institutional improvement so that radiological technologists can perform ultrasound examinations according to doctors' prescriptions without real-time guidance.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.