• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

A new concept for blast hardened bulkheads with attached aluminum foam

  • Kim, Sung-Ho;Woo, Heekyu;Choi, Gul-Gi;Yoon, Kyungho
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.243-250
    • /
    • 2018
  • The use of blast hardened bulkheads (BHBs) is an effective vulnerability hardening technique for improving the survivability of naval warships when internal explosions occur due to being shot by an anti-surface missile. In this paper, a new concept of BHBs reinforced by aluminum (Al) foam is proposed. The new concept can significantly reduce the blast pressures transferred to bulkheads and, unlike conventional BHBs, can be easily installed to operating naval warships. Chamber model blast tests were performed to demonstrate the effectiveness of the Al-foam BHBs and the results are further supported by numerical simulations. Finally, a practical preliminary is proposed for the Al-foam BHBs.

Osseous metaplasia showing heterotopic ossification in the maxillary sinus

  • Kang, Sang-Hoon;Chang, Jung Hyun
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.127-129
    • /
    • 2018
  • Radiopacity in the maxillary sinus can be observed in various conditions, such as in the presence of lesions in the maxillary sinus or as a sequela of maxillary sinus surgery. This report describes the case of a 57-year-old female patient who had no previous history of surgical treatment or traumatic injury of the nose or maxillary sinus. Both maxillary sinuses were indistinguishable on panoramic radiography and showed signs of radiopacity. Computed tomography images revealed that the maxillary sinuses were filled with bony tissue and exhibited signs of sinus mucosal thickening. Biopsy results showed fragments of trabecular bone with fibrous tissue.

Rhinolith: An incidental radiographic finding

  • Maheshwari, Nisha;Etikaala, Badirinath;Syed, Ali Z.
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.333-336
    • /
    • 2021
  • Rhinoliths are foreign bodies composed of mineralised deposits in the nasal cavity that are rarely encountered in routine dental practice. The current report presents a case of a 77-year-old female patient who visited a dental treatment centre for a routine dental check-up and prophylaxis. On the clinical examination, the patient did not report any breathing difficulty, nasal obstruction, or any form of discharge. Panoramic radiography showed a horizontally magnified radiopaque structure in the right nasal fossa region. Cone-beam computed tomography (CBCT) revealed a hyperdense entity with a laminated presentation in the right nasal fossa. The hyperdense entity was diagnosed as a rhinolith based on the radiographic findings. Although the patient was asymptomatic, a referral was made to an ear, nose, and throat surgeon for a further evaluation. This report highlights the importance of CBCT imaging in the diagnosis of soft-tissue calcifications.

Simultaneous growth of graphene and vertically aligned single-walled carbon nanotubes at low temperature by chemical vapor deposition

  • Hong, Suck Won;Kim, Kwang Ho;Jung, Hyun Kyung;Kim, Daesuk;Lee, Hyung Woo
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.154-157
    • /
    • 2012
  • We present the simultaneous growth of single-walled carbon nanotubes and graphene with the optimal conditions of the synthesizing parameters. The dense and vertically aligned SWNTs having the length of over 100 ㎛ was grown by 2 nm-thick Fe catalytic layer. From 650 ℃, the vertically well-grown SWNTs were obtained by increasing the temperature. The severallayered graphene was synthesized with the gas mixing ratio of 15 : 1(H2 : C2H2) at 650 ℃ and higher temperatures. With these optimal conditions, the vertically well-grown SWNTs and the several-layered graphene were synthesized simultaneously. The presence of SWNTs and the layer of graphene were verified by field emission scanning electron microscopy and high resolution transmission electron microscopy. From the result of this simultaneous synthesizing approach, the possibility of one step growth process of CNTs and grapheme could be verified.

Estimate of Radiation Doses in MDCT Using Patient Weight (MDCT 검사에서 환자 체중을 이용한 선량 평가)

  • Kwon, Seong-Ohk;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Choi, Ji-Won;Chung, Woon-Kwan
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2010
  • The purpose of this study provides measurements of radiation dose from MDCT of head, chest, abdomen and pelvic examinations. A series of dose quantities that are measured of patient weight to compare the dose received during MDCT examinations. Data collected included: weight together with CT dose descriptors, volume CT dose index (CTDIvol) and dose length product (DLP). The effective dose was also estimated and served as collective dose estimation data. Data from 1,774 adult patients attending for a CT examination of the head (n=520) or chest (n=531) or abdomen (n=724) was obtained from spiral CT units using a same CT protocol. Mean values of CTDIvol was a range of 48.6 mGy for head and 6.9, 10.5 mGy for chest, abdomen examinations, respectively. And mean values of DLP was range of 1,604 $mGy{\cdot}cm$ for head, 250 $mGy{\cdot}cm$ for chest, 575 $mGy{\cdot}cm$ for abdomen examinations, respectively. Mean effective dose values for head, chest, abdominal CT were 3.6, 4.2, and 8.6 mSv, respectively. The degree of CTDIvol and DLP was a positive correlation with weight. And there was a positive correlation for weight versus CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694) in chest. And head was also positive correlation with weight versus CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741). We conclude that CTDIvol and DLP is an important determinant of weight within the CT examinations. The results for this study suggest that CT protocol should be tailored according to patient weight.

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

A Convergent Study of the Physical Related Quality of Life Using SF-8 of Stroke Patient's Caregiver (뇌졸중 환자 보호자의 SF-8을 이용한 신체건강관련 삶의 질 융복합적 연구)

  • Kim, Young-Ran;Kim, Young-il;Kim, Min-jeong
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.119-127
    • /
    • 2017
  • This paper convergent examined caregiver burden, depressive symptoms and health related quality of life of 226 caregivers of stroke patients, who had been hospitalized in 7 general hospitals located in Cheongju and Daejeon Metropolitan city. The quality of life was measured using SF-8, which is a short version of HRQoL. According to Multiple regression Analysis, dependence of a patient were important factors in the physical related quality of life. These results suggest that in order to improve the quality of life related to the physical health of the stroke patient's caregiver, the elderly long-term care insurance system and the caregiver system and the ward of the Ministry of Health and Welfare are expanded ward without a caregiver. There is a need to raise expectations for recovery through education and family support groups.

A Study of Targetry Activation and Dose Analysis of PET Cyclotron Using Monte Carlo Simulation (몬테카를로 모의 모사를 이용한 의료용 사이클로트론의 Targetry 방사화 및 피폭선량 분석)

  • Jang, Donggun;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.565-573
    • /
    • 2018
  • Cyclotron for medical purposes generates nuclear reaction by accelerating protons in high speed, in order to produce radiopharmaceuticals, and unnecessary neutrons are generated through such nuclear reaction. Neutrons cause activation in the parts of cyclotron which then cause exposure to radiation for people working in the field. This study, in that regard, aims to analyze exposure level by finding out the degree of activation of aluminum body, silver body, and havar foil which are the parts of Targetry where the nuclear reaction takes place. The results of the experiment showed that aluminum body and silver body had no problems re-using them as the energy and half-life of activated nuclides were small and short, making the affect on the people working in the field extremely low. However for havar foil, its activated nuclides had a high level of energy which resulted in high level of affect to the people working in the field. The activation factors of the cyclotron were analyzed, and the results showed that the Havar foil was activated the most among the targetry parts, and greatly exposed workers due to regular replacement, and needed special management as radioactive waste.

The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT (두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가)

  • Kwon, Soonmu;Kim, Jungsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.279-285
    • /
    • 2015
  • The eye of human is a radiation sensitive organ and this organ should be shielded from radiation exposure during brain CT procedures. In the brain CT procedures, bismuth protector using to reduce the radiation exposure dose for eye. But protecting the bismuth always accompanies problem of the image quality reduction including artifact. This study aim is the eye radiation exposure dose and image quality evaluation of the new tube current modulation such as new organ based-tube current modulation, longitudinal-TCM, angular-TCM between shielding scan technique using bismuth and lead glasses. As a result, radiation dose of eye is reduced 25.88% in new OB TCM technique then reference scan technique and SNR new OB TCM is 6.05 higher than bismuth shielding scan technique and lower than reference scan technique. In clinical brain CT, new OB TCM technique will contribute to reduction of radiation dose for eye without decrease of image quality.