• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

Potential Risk Assessment of Cardiovascular Disease in Low Calcium-Score (낮은 칼슘 수치에서 심혈관질환의 잠재 위험도 평가)

  • Yoo, Heangsoo;Park, Jikoon;Jung, Bongjae;Noh, Sicheol;Choi, IlhHong;Jung, Hyungjn;Kang, Sangsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.369-376
    • /
    • 2013
  • Prepared her for the early detection of the risk of cardiovascular disease prevention for the various attempts being made ill through a lot of research to the criteria of coronary artery calcification, but the figure is more than 100 the progress of the flow can be expected to be was. In this study, we quantify the correlation between body composition analysis, blood lipid levels of calcium and public asymptomatic even at low calcium levels in comparison with the existing studies by analyzing potential risk of cardiovascular disease will be represented on the were evaluated. Studies, the calcium scores in the body composition analysis "1-10", and when "11-100" when there was a significant correlation in BMI and WHR look more normal frequency range of the mean values in the normal range meomulreoteuna 21% relative HDL and TG in lipid profiles, no significant correlation look more normal frequency range of risk were derived from the mean values in the normal range, 21% to 40% of the relative risk were derived. meomulreoteuna. In addition, there is no correlation between BFM and BMR Also, average increases in the frequency of a higher standard was higher relative risk derived 31 to 93%, and geological correlation test TC above 20mg/dl atherosclerotic sclerosis seems to be the value of HDL to act to remove cholesterol from atheroma already looking at the same time to suppress the occurrence of atherosclerosis, increased LDL showed higher values occurs rapidly increasing. At this time, the relative risk of 43-50% have been identified. In other words, even when calcium levels are low, that is inherent in the incidence of cardiovascular disease was unknown.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Statistical Study on Respiratory Signal Analysis according to Patient Position and Device in Radiation Therapy (방사선치료 시 자세와 device에 따른 호흡신호의 분석)

  • Seo, Jeong-Min;Park, Myung-Hwan;Shim, Jae-Koo;Kim, Chan-Hyeong;Park, Cheol-Soo;Kim, Kyung-Keun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 2011
  • This study statistically analyzed the difference of the stability of maintaining a respiratory period shown according to position and use of a device to search the tendency and usefulness of a device. The supine position showed better maintaining respiratory cycles than the prone position. The 85% of subjects who showed bad maintenance pattern of a respiratory cycle were significantly different pattern with using belly board. It could be said that there was a significant correlation between the maintenance of a respiratory cycle and relative index of respirational stability(p=0.044, kappa=0.607). The movement due to respiration was one of important considerations in the radiation therapy on chest, abdomen, and even pelvis. This study could contribute to the high quality radiation therapy by statistic analysis of respiratory signals and its application.

Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

  • Gupta, Sunil Kumar;Gupta, Jaya;Acharya, Shashi Rashmi;Ather, Amber
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.123-128
    • /
    • 2013
  • Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

Post-traumatic bifid mandibular condyle: A case report and literature review

  • Woo, Min-Ho;Yoon, Kyu-Ho;Park, Kwan-Soo;Park, Jae-An
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.217-222
    • /
    • 2016
  • Bifid mandibular condyle (BMC) is an uncommon morphological variant of the mandibular condyle. Although authors have proposed various etiologies for BMC, no consensus has emerged. In addition, varying findings have been reported regarding the epidemiological parameters of BMC (e.g., prevalence, gender ratio, and age), possibly due to its low incidence. BMC is occasionally associated with symptoms of the temporomandibular joint, such as ankylosis, pain, and trismus; however, it is difficult to detect this condition on conventional radiographs. This study reports a case of BMC with radiographic findings, and reviews the literature on the epidemiology of BMC.

Radiologic Diagnosis of Temporomandibular Joint (측두하악관절의 영상진단)

  • Park, Hyok;Chung, A-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.291-299
    • /
    • 2012
  • There are many kinds of techniques for imaging temporomandibular joints. None of them for imaging "best fit" for every patient of temporomandibular disorder is recommended ideally. It is more important to be able to select the modality that is most adequate and appropriate for a given clinical issue.

Unicystic ameloblastoma with diverse mural proliferation - a hybrid lesion

  • Mahadesh, Jyothi;Rayapati, Dilip Kumar;Maligi, Prathima M.;Ramachandra, Prashanth
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • A 46-year-old man was referred to our hospital for treatment, complaining of swelling on the right mandibular molar region. Radiographic examination revealed a well defined multilocular radiolucent lesion with root resorption of right lower anteriors and molars. Following biopsy, a diagnosis of unicystic ameloblastoma of mural type was made and hemimandibulectomy was performed under general anesthesia. Histopathological examination of the surgical specimen exhibited a unicystic ameloblastoma of luminal, intraluminal, and mural type. Intraluminal proliferation was of plexiform pattern and mural proliferation showed unusual histopathological findings, which revealed follicular, acanthomatous areas coexisted with desmoplastic areas. This mural picture was similar to the so-called 'hybrid lesion of ameloblastoma', whose biological profile is not elicited due to the lack of adequate published reports. Two years follow up till date has not revealed any signs of recurrence.

Osteosarcoma of the mandible: A case report with an early radiographic manifestation

  • Samraj, Lavanya;Kaliamoorthy, Sriram;Venkatapathy, Ramesh;Oza, Nirima
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2014
  • Osteosarcoma is a classical malignant bone-forming neoplasm which usually presents with an aggressive clinical course. The current case is presented with the radiographic feature of widening of the periodontal ligament space of the involved teeth, which is considered to be the earliest radiographic manifestation of osteosarcoma involving the jaw bone. The main aim of this case report was to focus on the importance of early diagnosis of this tumor based on clinical and radiographic examinations, and confirmation by histopathology. Considering the rarity of the disease type and particularly taking into account the fast progression and aggressiveness of this neoplasm, it is clear that the presentation of a clinical case represents a major contribution to better understanding of osteosarcomas involving the jaw bone.

Multiple intraosseous cervical pneumatocysts: A case report of a rare incidental finding on cone-beam computed tomography

  • Jadhav, Aniket B.;Sarah, Sangeetha Gajendran;Cederberg, Robert;Wagh, Aditya;Kiat-amnuay, Sudarat
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.223-226
    • /
    • 2018
  • This report presents a case of cervical pneumatocysts as an incidental finding on cone-beam computed tomography. Pneumatocysts are gas-containing lesions of unknown etiology. They usually present in the ilium or sacrum, adjacent to the sacroiliac joint. In the literature, 21 case reports have described cervical pneumatocysts. Cervical pneumatocysts should be differentiated from other lesions, such as osteomyelitis, osteonecrosis, and neoplasms, as well as post-traumatic and post-surgical cases. Computed tomography, cone-beam computed tomography, and magnetic resonance imaging are appropriate tools to diagnose cervical pneumatocysts.