• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.033 seconds

Steatocystoma multiplex: A case report of a rare entity

  • Shin, Nan-Young;Kang, Ju Hee;Kim, Jo-Eun;Symkhampa, Khantaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.317-321
    • /
    • 2019
  • Steatocystoma multiplex is an uncommon benign skin disease, which typically manifests as numerous intradermal cysts that can be scattered anywhere on the body. Although usually asymptomatic, it can be significantly disfiguring. One type of steatocystoma multiplex is known to be associated with the autosomal dominant inheritance of a mutation in the gene coding for keratin 17 (KRT17). In such cases, it is often concurrent with other developmental abnormalities of the ectoderm-derived tissues, such as the nails, hair, and teeth. To the best of our knowledge, few cases have been reported of steatocystoma multiplex of the oral and maxillofacial region. This report describes a case of steatocystoma multiplex of both sides of the neck and multiple dental anomalies, with a focus on its clinical, radiological, and histopathological characteristics, as well as the possibility that the patient exhibited the familial type of this condition.

The influence of X ray beam angulation on the fractal analysis of trabecular architecture in human dry mandible using standardized tile counting method

  • Lee Kyung-Hee;Lee Sun-Bok;An Chang-Hyeon;Heo Min-Suk;Yi Won-Jin;Huh Kyung-Hoe;Park Moo-Soon;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.179-182
    • /
    • 2004
  • Purpose: The purpose of this study is to examine the effects of X-ray beam angulation on the fractal dimension of trabecular bone structure of human dry mandible using the tile counting method. Materials and Methods: We divided 5 human dry mandibles into an angle and a molar groups depending on the regions and deciding the region of interest (ROI). When contrasted with the ROI, the inferior cortex was appointed to be low and the lines perpendicular to the buccal cortex were appointed to be the standard angle. Direct digital intraoral radiographs were obtained from 9 different projection angles. We analyzed statistically the fractal dimension using the tile counting method. Results: There was a statistically significant difference in the fractal dimension of the regions and the mandibles, but there was no statistically significant difference in the fractal dimension according to the X-ray beam angulation. Conclusion : There is no statistically significant effect of the angle of the projection on the fractal dimension of trabecular bone structure of a human dry mandible according to the tile counting method.

  • PDF

Transpedal lymphatic embolization for lymphorrhea at the graft harvest site after coronary artery bypass grafting

  • Cha, Jung Guen;Lee, Sang Yub;Hong, Jihoon;Ryeom, Hun Kyu;Kim, Gab Chul;Do, Young Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.74-77
    • /
    • 2021
  • Lymphorrhea is a rare but potentially severe complication that occurs after various surgical procedures. Untreated lymphorrhea may lead to wound dehiscence, infection, and prolonged hospital stay. Currently, there is no standard effective treatment. Early management usually includes leg elevation, drainage, and pressure dressing. However, these methods are associated with prolonged recovery and high recurrence rates. We report a case of lymphorrhea from a calf wound after endoscopic great saphenous vein (GSV) harvesting for coronary artery bypass grafting (CABG). The patient presented with intractable oozing from the postoperative wound on the right calf. Lymphorrhea persisted for 6 weeks despite negative-pressure wound therapy with a long-acting somatostatin. We performed unilateral pedal lymphangiography that confirmed wound lymphorrhea, followed by glue embolization. No recurrence was observed after 8 months of follow-up. This case report demonstrates the successful use of lymphangiography with glue embolization in the control of lymphorrhea after GSV harvesting for CABG.

Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

  • Yoon, Kaeng Won;Yoon, Suk-Ja;Kang, Byung-Cheol;Kim, Young-Hee;Kook, Min Suk;Lee, Jae-Seo;Palomo, Juan Martin
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.207-212
    • /
    • 2014
  • Purpose: This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Materials and Methods: Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. Results: The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. Conclusion: In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

Stiffness of the Central Corpus Cavernosum on Shear-Wave Elastography Is Inversely Correlated with the Penile Rigidity Score in Patients with Erectile Dysfunction

  • Joo Yong Lee;Dae Chul Jung;Seungsoo Lee;Nam Gyu Kang;Young Taik Oh;Kyunghwa Han
    • The World Journal of Men's Health
    • /
    • v.39 no.1
    • /
    • pp.123-130
    • /
    • 2021
  • Purpose: To perform real-time quantitative measurements of penile rigidity for patients with erectile dysfunction (ED) using shear-wave elastography (SWE). Materials and Methods: A total of 92 patients with clinically diagnosed ED filled out an abridged five-item version of the International Index of Erectile Function (IIEF-5) questionnaire and underwent SWE as well as penile color Doppler ultrasound (CDUS) after intracavernosal injection for penile erection. Elasticity measurements were repeated on two sites of the corpus cavernosum (central and peripheral elasticity of corpus cavernosum [ECC]) and the glans penis during the erection phase. Correlations between penile elasticity and rigidity scores or IIEF-5 were evaluated statistically. Penile elasticity was also compared with the ED types based on CDUS. Results: The mean age of all patients was 53.5±13.4 years, and the mean IIEF-5 score was 9.78±5.01. The rigidity score and central ECC value demonstrated a significant correlation (r=-0.272; 95% confidence interval: -0.464 to -0.056; p=0.015). The IIEF-5 score was not significantly correlated with penile elasticity. Vascular ED patients showed significantly higher central ECC values than nonvascular ED patients (p<0.001). At a cut-off value of 8.05 kPa, the central ECC had a specificity of 41.5%, a sensitivity of 84.6%, and an area under the ROC curve of 0.720 with a standard error of 0.059 (p=0.019) for predicting vascular ED. Conclusions: Quantitatively measuring Young's modulus of the corpus cavernosum using SWE could be an objective technique for assessing penile erectile rigidity and the vascular subtype in patients with ED.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.

Development and Validation of a Deep Learning System for Segmentation of Abdominal Muscle and Fat on Computed Tomography

  • Hyo Jung Park;Yongbin Shin;Jisuk Park;Hyosang Kim;In Seob Lee;Dong-Woo Seo;Jimi Huh;Tae Young Lee;TaeYong Park;Jeongjin Lee;Kyung Won Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.88-100
    • /
    • 2020
  • Objective: We aimed to develop and validate a deep learning system for fully automated segmentation of abdominal muscle and fat areas on computed tomography (CT) images. Materials and Methods: A fully convolutional network-based segmentation system was developed using a training dataset of 883 CT scans from 467 subjects. Axial CT images obtained at the inferior endplate level of the 3rd lumbar vertebra were used for the analysis. Manually drawn segmentation maps of the skeletal muscle, visceral fat, and subcutaneous fat were created to serve as ground truth data. The performance of the fully convolutional network-based segmentation system was evaluated using the Dice similarity coefficient and cross-sectional area error, for both a separate internal validation dataset (426 CT scans from 308 subjects) and an external validation dataset (171 CT scans from 171 subjects from two outside hospitals). Results: The mean Dice similarity coefficients for muscle, subcutaneous fat, and visceral fat were high for both the internal (0.96, 0.97, and 0.97, respectively) and external (0.97, 0.97, and 0.97, respectively) validation datasets, while the mean cross-sectional area errors for muscle, subcutaneous fat, and visceral fat were low for both internal (2.1%, 3.8%, and 1.8%, respectively) and external (2.7%, 4.6%, and 2.3%, respectively) validation datasets. Conclusion: The fully convolutional network-based segmentation system exhibited high performance and accuracy in the automatic segmentation of abdominal muscle and fat on CT images.

Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films (구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가)

  • Lee Sang-Sub;Kwon Hyok-Rak;Sim Woo-Hyoun;Oh Seung-Hyoun;Lee Ji-Youn;Jeon Kug-Jin;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

Prospective Multi-Center Korean Registry of Transcatheter Arterial Chemoembolization with Drug-Eluting Embolics for Nodular Hepatocellular Carcinoma: A Two-Year Outcome Analysis

  • Myungsu Lee;Jin Wook Chung;Kwang-Hun Lee;Jong Yun Won;Ho Jong Chun;Han Chu Lee;Jin Hyoung Kim;In Joon Lee;Saebeom Hur;Hyo-Cheol Kim;Yoon Jun Kim;Gyoung Min Kim;Seung-Moon Joo;Jung Suk Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1658-1670
    • /
    • 2021
  • Objective: To assess the two-year treatment outcomes of chemoembolization with drug-eluting embolics (DEE) for nodular hepatocellular carcinoma (HCC). Materials and Methods: This study was a prospective, multicenter, registry-based, single-arm trial conducted at five university hospitals in Korea. Patients were recruited between May 2011 and April 2013, with a target population of 200. A DC Bead loaded with doxorubicin was used as the DEE agent. Patients were followed up for two years. Per-patient and per-lesion tumor response analysis, per-patient overall survival (OS) and progression-free survival (PFS) analysis, and per-lesion tumor control analysis were performed. Results: The final study population included 152 patients, with 207 target lesions for the per-lesion analysis. At one-month, six-month, one-year, and two-year per-patient assessments, complete response (CR) rates were 40.1%, 43.0%, 33.3%, and 19.6%, respectively. The objective response (OR) rates were 91.4%, 55.4%, 35.1%, and 19.6%, respectively. The cumulative two-year OS rate was 79.7%. The cumulative two-year PFS rate was 22.4% and the median survival was 9.3 months. In multivariable analysis, the Child-Pugh score (p = 0.019) was an independent predictor of OS, and tumor multiplicity (p < 0.001), tumor size (p = 0.020), and Child-Pugh score (p = 0.006) were independent predictors of PFS. In per-lesion analysis, one-month, six-month, one-year and two-year CR rates were 57.5%, 58.5%, 45.2%, and 33.3%, respectively, and the OR rates were 84.1%, 65.2%, 46.6%, and 33.3%, respectively. The cumulative two-year per-lesion tumor control rate was 36.2%, and the median time was 14.1 months. The Child-Pugh score (p < 0.001) was the only independent predictor of tumor control. Serious adverse events were reported in 11 patients (7.2%). Conclusion: DEE chemoembolization for nodular HCCs in the Korean population showed acceptable survival, tumor response, and safety profiles after a two-year follow-up. Good liver function (Child-Pugh score A5) was a key predictor of per-patient OS, PFS, and per-lesion tumor control.

Sialadenitis caused by iatrogenic trauma: A case report (의원성 사고로 발생한 타액선염:증례보고)

  • Kim Hyun-Woo;Huh Kyung-Hoe;Lee Win-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.107-110
    • /
    • 2004
  • A case of sialadenitis is presented in a patient with painful swelling of the right mouth floor. The condition was caused by trauma on the right mouth floor during dental treatment, which had happened 15 days before admission. On aspiration, mucous secretion was found and ultrasonography showed obstruction of duct. Histopathological studies and surgical investigation established a definite diagnosis of obstructive sialadenitis caused by ductal laceration. As surgical treatment sialodochoplasty was selected. The case and relevant considerations are discussed.

  • PDF