• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties (유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jeon, Je-Hoon;Kim, Joo-Hee;Heo, Ye-Ji;Kang, Sang-Sik;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.611-617
    • /
    • 2017
  • In this study, it was expected that long-term stability against external mechanical external force could be secured if the phosphor layer had ductility. In this study, a bendable $Gd_2O_2S:Tb$ sensitized paper was fabricated by screen printing method and the image uniformity was evaluated through RMS analysis and histogram analysis to investigate the effect of fatigue accumulation due to long-term external force and repetitive external force. As a result, the dominant pixel area is maintained constant and the relative standard deviation is less than 10% for the long-term external force. However, for the repetitive external force, the dominant pixel area is divided into three areas and the image uniformity is adversely affected. Based on these results, it is suggested that the curved surface detector can be applied by securing the mechanical stability against the existing radiation sensitized paper. However, further studies are needed to apply it to the flexible detector. As a result, flexible radiation sensitizers can be applied to various curved surfaces, and it is expected to be applicable to various fields such as nuclear medicine, medical treatment, and industrial fields in the future.

Study on electrical properties of photoconductors for radiation detector application based on liquid crystal (액정 기반 방사선 검출기 적용을 위한 광도전체의 전기적 특성 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Mi-Hyun;Kim, Hyun-Hee;No, Si-Chul;Cho, Kyu-Suck;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.27-30
    • /
    • 2010
  • A X-ray optical modulator measures x-ray dose using optical transmissivity ratio change of the liquid crystal cell. To apply in this optical modulator, we made photoconductor films and compared electrical properties of this films in this study. Photoconductors are deposited on ITO glass with $200{\mu}m$ using the percipitation method and print method. I-V test was conducted to alalyze electrical properties of this films and measured darkcurrent and SNR was acquired using the measured dark current and sensitivity. As a result of this measurements, $HgI_2$ film made by precipitation method is lower(about 40%) darkcurrent than $HgI_2$ films made by precipitation method and sensitivity is two times greater than print method. And we knew that $HgI_2$ films were also 10~25 times greater SNR at $1v/{\mu}m$ than $PbI_2$, PbO, CdTe film made by precipitation method. This results suggest that $HgI_2$ films made by precipitation method has improved characteristics of x-ray dose meter by applying in x-ray optical modulator.

Solitary Plasmacytoma of the Bone: Radiologic Findings (골단일 형질세포종 : 방사선학적 소견)

  • Yoon, Choon-Sik;Kim, Myung-Joon;Ahn, Chang-Soo;Suh, Jin-Suck;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.2
    • /
    • pp.61-68
    • /
    • 2000
  • Purpose : We examined the patients to evaluate the radiologic findings of solitary plasmacytoma of the bone. Materials and Methods : We retrospectively reviewed radiologic findings of 9 cases with solitary plasmacytoma of the bone (SPB) for recent 5 years, but 2 cases were not included this study due to an abnormal finding of bone marrow and another 2 cases were not included due to an abnormal manifestations of computed tomography (n=1) and MRI (n=1). Results : Among 5 cases, 4 cases had an osteolytic bone destruction and 1 case had an osteosclerotic bone destruction on the plain radiograph. Computed tomography and MRI showed more informations about trabeculated bone destruction and the soft-tissue extension of the lesion comparing to plain radiographs. The MRI finding of SPB in 4 cases showed a relatively high signal intensity on T1-weighted image and intermediate signal intensity on T2-weighted image, on which the signal intensity of the lesion is slightly higher than that of the muscle. One case had an extensive soft-tissue involvement and multiple necrosis, which presented iso to low signal intensity on T1-weighted image and high heterogeneous signal intensity on T2-weighted image. The Gadolinium-enhanced T1-weighted images of 5 cases showed diffusely strong enhancement of the lesion except on the necrosis areas. Conclusion : Computed tomography and MRI may present some characteristics of SPB and demonstrate another foci of plasma cell infiltrates, so these can be helpful for the diagnosis and treatment of SPB.

  • PDF

Dynamic Contrast-Enhanced MR Imaging in Detecting Local Tumor Progression after HIFU Ablation of Localized Prostate Cancer (국소적 전립선암의 고강도 집속 초음파 치료 후 국소적 암 재발의 발견과 역동적 조영증강 자기공명영상의 역할)

  • Park, Jung Jae;Kim, Chan Kyo;Lee, Hyun Moo;Park, Byung Kwan;Park, Sung Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • Purpose : To retrospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging (DCE-MRI) in detecting recurrent prostate cancer after HIFU of clinically localized cancer, as compared with T2-weighted imaging (T2WI). Materials and Methods: Twenty-six patients with increased prostate-specific antigen levels after HIFU were included in this study. All MR examinations were performed using T2WI and DCE-MRI, followed by transrectal ultrasound-guided biopsy. MRI and biopsy results were correlated in six prostate sectors. Residual or recurrent cancer after HIFU was defined as local tumor progression if biopsy results showed any cancer foci. Two independent readers interpreted the MR images. Results: Of 156 prostate sectors, 51 (33%) were positive for cancer in 17 patients. For detecting local tumor progression, the sensitivity of DCE-MRI and T2WI was 80% and 57% for reader 1 (P < 0.001) versus 84% and 61% for reader 2 (P < 0.001), respectively. The specificity and overall accuracy between DCE-MRI and T2WI showed no statistical difference in both readers (P > 0.05). Interobserver agreement of DCE-MRI and T2WI was moderate and fair, respectively. Conclusion: For detecting local tumor progression of prostate cancer after HIFU, DCE-MRI was more sensitive than T2WI, with less interobserver variability.

A Fundamental Study on the Fabrication of Human Model Bone Phantom using an Entry-Level 3D Printer: using FDM Method for the Femur Model (보급형 3D 프린터를 이용한 인체 모형 뼈 팬텀 제작의 기초연구: Femur 대상으로 적층형 출력 방식 이용)

  • Namkung, Eun-Jae;Kim, Do-Hee;Kim, So-Hui;Park, Se-Eun;Jung, Dabin;Park, Sang-Hyub;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.651-660
    • /
    • 2020
  • The purpose of this study was to create a phantom with a HU value similar to that of the human Femur using a 3D printer to replace the existing pig bone. A total of 372 people were analyzed to determine the HU value of human Femur. Using a 3D printer, a human bone model phantom was fabricated using PLA-Cu 20% and subjected to CT examination. Pig bones were 6 months old pigs, and bones 2 days after slaughter were used. As a result of the examination, the 3D printing phantom made with 80% of the internal filling showed a similar value to all data of the human body (p<0.05), and there was a difference from the pig bone (p>0.05). In addition, in the case of the HU value of Femur by age group, it was confirmed that the value of HU decreased as the age group increased (p<0.05). 3D printing and HU values confirmed a weak negative correlation with respect to the stacking height, but confirmed a strong positive correlation (R2 = 0.996) with 182.13±1.290 in the inner filling (p<0.05). In conclusion, it was confirmed that the human body model phantom using 3D printing can exhibit a similar level of HU value to the human body compared to the existing pig bone phantom, and this study will provide basic data for the production of a human body model phantom using a 3D printer.

Dual Component Analysis for In Vivo T2* Decay of Hyperpolarized 13C Metabolites

  • Joe, Eunhae;Lee, Joonsung;Lee, Hansol;Yang, Seungwook;Choi, Young-Suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: To investigate the exchange and redistribution of hyperpolarized $^{13}C$ metabolites between different pools by temporally analyzing the relative fraction of dual $T_2{^*}$ components of hyperpolarized $^{13}C$ metabolites. Materials and Methods: A dual exponential decay analysis of $T_2{^*}$ is performed for [1-$^{13}C$] pyruvate and [1-$^{13}C$] lactate using nonspatially resolved dynamic $^{13}C$ MR spectroscopy from mice brains with tumors (n = 3) and without (n = 4) tumors. The values of shorter and longer $T_2{^*}$ components are explored when fitted from averaged spectrum and temporal variations of their fractions. Results: The $T_2{^*}$ values were not significantly different between the tumor and control groups, but the fraction of longer $T_2{^*}$ [1-$^{13}C$] lactate components was more than 10% in the tumor group over that of the controls (P < 0.1). The fraction of shorter $T_2{^*}$ components of [1-$^{13}C$] pyruvate showed an increasing tendency while that of the [1-$^{13}C$] lactate was decreasing over time. The slopes of the changing fraction were steeper for the tumor group than the controls, especially for lactate (P < 0.01). In both pyruvate and lactate, the fraction of the shorter $T_2{^*}$ component was always greater than the longer $T_2{^*}$ component over time. Conclusion: The exchange and redistribution of pyruvate and lactate between different pools was investigated by dual component analysis of the free induction decay signal from hyperpolarized $^{13}C$ experiments. Tumor and control groups showed differences in their fractions rather than the values of longer and shorter $T_2{^*}$ components. Fraction changing dynamics may provide an aspect for extravasation and membrane transport of pyruvate and lactate, and will be useful to determine the appropriate time window for acquisition of hyperpolarized $^{13}C$ images.

Artificial Intelligence Based Medical Imaging: An Overview (AI 의료영상 분석의 개요 및 연구 현황에 대한 고찰)

  • Hong, Jun-Yong;Park, Sang Hyun;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.195-208
    • /
    • 2020
  • Artificial intelligence(AI) is a field of computer science that is defined as allowing computers to imitate human intellectual behavior, even though AI's performance is to imitate humans. It is grafted across software-based fields with the advantages of high accuracy and speed of processing that surpasses humans. Indeed, the AI based technology has become a key technology in the medical field that will lead the development of medical image analysis. Therefore, this article introduces and discusses the concept of deep learning-based medical imaging analysis using the principle of algorithms for convolutional neural network(CNN) and back propagation. The research cases application of the AI based medical imaging analysis is used to classify the various disease(such as chest disease, coronary artery disease, and cerebrovascular disease), and the performance estimation comparing between AI based medical imaging classifier and human experts.

Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography (유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils (6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.699-706
    • /
    • 2018
  • In this study, we measured signal intensities according to array coil position changes to provide reference data of coil directions and the distances as it deters image quality unless the coils are aligned properly. The multi-purpose MRI phantom was placed in body array coils, and it was moved to the top, bottom, left, and right directions by 2 cm from the center to 10 cm. After obtaining images, signal intensities were measured and compared. The results of this study were as follows: Except for the upward direction, the signal intensities of the reference signal was not significantly different from that of the reference signal intensity within 2cm in both T1 and T2-weighted images. In conclusion, in clinical circumstances which various challenges exist to align the coils exactly on the same lines, array coils should be positioned at least within 2 cm from the center except for the upward direction, on the same line to prevent the image qualities are lowered.