• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

Prevalence and location of the posterior superior alveolar artery using cone-beam computed tomography

  • Tehranchi, Maryam;Taleghani, Ferial;Shahab, Shahriar;Nouri, Arash
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.39-44
    • /
    • 2017
  • Purpose: Insufficient knowledge of the anatomy of the maxillary sinuses prior to sinus graft surgery may lead to perioperative or postoperative complications. This study sought to characterize the position of the posterior superior alveolar artery (PSAA) within the maxillary sinuses using cone-beam computed tomography (CBCT). Materials and Methods: A total of 300 patients with edentulous posterior maxillae, including 138 females and 162 males with an age range of 33-86 years, who presented to a radiology clinic between 2013 and 2015 were enrolled in this retrospective cross-sectional study. The distance from the inferior border of the PSAA to the alveolar crest according to the residual ridge classification by Lekholm and Zarb, the distance from the PSAA to the nasal septum and zygomatic arch, and the diameter and position of the PSAA were all assessed on patients' CBCT scans. The data were analyzed using the Mann-Whitney test and the t-test. Results: The PSAA was detected on the CBCT scans of 87% of the patients; it was located beneath the sinus membrane in 47% of cases and was intraosseous in 47% of cases. The diameter of the artery was between 1 and 2 mm in most patients (72%). The mean diameter of the artery was $1.29{\pm}0.39mm$, and the mean distances from the PSAA to the zygomatic arch, nasal septum, and alveolar crest were $22.59{\pm}4.89mm$, $26.51{\pm}3.52mm$, and $16.7{\pm}3.96mm$, respectively. Conclusion: The likelihood of detecting the PSAA on CBCT scans is high; its location is intraosseous or beneath the sinus membrane in most patients. Determining the exact location of the PSAA on CBCT scans preoperatively can help prevent it from being damaged during surgery.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

  • Ramesh, Aruna;Soroushian, Sheila;Ganguly, Rumpa
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.235-243
    • /
    • 2013
  • Purpose: This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. Materials and Methods: One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. Results: There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, "With CCAP" and "Without CCAP", there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. Conclusion: This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

Reproducibility of cone-beam computed tomographic measurements of bone plates and the interdental septum in the anterior mandible

  • Valerio, Claudia Scigliano;Alves, Claudia Assuncao e;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose: This study aimed to introduce a novel method to evaluate the alveolar bone and interdental septum in the anterior mandible using cone-beam computed tomography (CBCT). Materials and Methods: Fifty-six CBCT scans from adult patients were selected. The CBCT scans were obtained before and after orthodontic treatment. The following measurements were taken: width of the alveolar bone and the interdental septum, height of the interdental septum, height of the bone plates, distance between the cementoenamel junction and marginal bone crests, and vertical positioning of the mandibular incisor, using the lingual plane as a reference. To test the reproducibility and the stability of the lingual plane, a triangle was traced in the anterior mandible. The intra-class correlation coefficient(ICC) was used to determine intra- and inter-examiner agreement. The paired Student t-test was used to evaluate the area of the triangle and the reproducibility of all measurements. Results: The ICC was excellent for the alveolar bone and dental measurements (0.9989 and 0.9977, respectively), as well as for the interdental septum (0.9987 and 0.9961, respectively). The area of the triangles showed stability in the lingual plane (P>0.05). For the alveolar bone, mandibular incisor, and interdental septum measurements, no statistically significant differences were found between the 2 examiners(P>0.05), confirming the technical reliability of the measurements. Conclusion: The method used in this study provides a valid and reproducible assessment of alveolar bone dimensions in the anterior mandible measured on CBCT images.

Ultrasonographic evaluation of the masseter muscle in patients with temporomandibular joint degeneration

  • Busra Arikan;Numan Dedeoglu;Aydin Keskinruzgar
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.355-363
    • /
    • 2023
  • Purpose: Sonographic elastography can be used to evaluate the hardness of muscle tissue through the application of compression. Strain elastography gauges hardness through the comparison of echo sets before and after compression. This study utilized ultrasonography to measure the thickness and hardness of the masseter muscle in individuals with temporomandibular joint(TMJ) osteoarthritis. Materials and Methods: This study included 40 patients who presented with joint pain and were diagnosed with TMJ osteoarthritis via diagnostic cone-beam computed tomography, along with 40 healthy individuals. The thickness and hardness of each individual's masseter muscle were evaluated both at rest and at maximum bite using ultrasonography. The Mann-Whitney U test and the chi-square test were employed for statistical analysis, with the significance level set at P<0.05. Results: The mean thickness of the resting masseter muscle was 0.91 cm in patients with osteoarthritis, versus 1.00 cm in healthy individuals. The mean thickness of the masseter muscle at maximum bite was 1.28 cm in osteoarthritis patients and 1.36 cm in healthy individuals. The mean masseter elasticity index ratio at maximum bite was 4.51 in patients with osteoarthritis and 3.16 in healthy controls. Significant differences were observed between patients with osteoarthritis and healthy controls in both the masseter muscle thickness and the masseter elasticity index ratio, at rest and at maximum bite (P<0.05). Conclusion: The thickness of the masseter muscle in patients with TMJ osteoarthritis was less than that in healthy controls. Additionally, the hardness of the masseter muscle was greater in patients with TMJ osteoarthritis.

Evaluation of the condylar movement on MRI during maximal mouth opening in patients with internal derangement of TMJ; comparison with trans cranial view (악관절 내장증 환자의 최대 개구시 하악과두 운동량에 대한 자기공명영상 평가; 경두개촬영법과의 비교)

  • Cho Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.185-192
    • /
    • 2001
  • Purpose: To evaluate the condylar movement at maximal mouth opening on MRI in patients with internal derangement. Materials and Methods: MR images and transcranial views for 102 TMJ s in 51 patients were taken in closed and maximal opening positions, and the amount of condylar movement was analyzed quantitatively and qualitatively. Results: For MR images, the mean condylar movements were 9.4 mm horizontally, 4.6 mm vertically and 10.9 mm totally, while those for transcranial views were 12.5 mm, 4.6 mm, and 13.7 mm respectively. The condyle moved forward beyond the summit of the articular eminence in 41 TMJs (40.2%) for MR images and 56 TMJs (54.9%) for transcranial views. Conclusion: The horizontal and total condylar movements were smaller in MR images than in transcranial views.

  • PDF

Observation of bilaminar zone in magnetic resonance images of temporomandibular joint

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.221-225
    • /
    • 2001
  • Purpose: To observe the relationship of bilaminar zone of temporomandibular joint retrodiscal tissues to the disc condition. Materials and Methods : The upper and lower stratum of bilaminar zone were identified on magnetic resonance open mouth images of 148 joints from 74 patients with disc displacements. Results: Both strata were identifiable in 105 joints which had disc displacement with reduction. Lower stratum was not identifiable in 35 joints which had disc displacement without reduction but 12 of 35 had hyalinized posterior attachment where the disc was. The 8 joints which had partial disc displacement without reduction showed identifiable lower stratum at the reducing site which was medial. Conclusion: Disruption or no identification of lower stratum which corresponds to the condylar portion of posterior attachment may be the sign of disc displacement without reduction.

  • PDF

Tomographic study of temporomandibular joints before orthodontic treatment (교정치료 전 환자의 측두하악관절에 관한 방사선학적 연구)

  • Kwon Ki-Jeong
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.193-197
    • /
    • 2001
  • Purpose : To determine whether there is a relationship between abnormal temporomandibular joint radiographic findings and age or gender in a sample of preorthodontic patients. Materials and Methods : Individualized corrected sagittal tomographs of 188 temporomandibular joints in 94 preorthodontic patients, aged 11 to 29 years, were taken and viewed by an observer blinded to clinical records. The study population was divided into 2 aged groups (11-15 years and 16-29 years) for comparative purposes. Temporomandibular joint radiographic findings were classified as normal or abnormal. Results: There was no difference in ratio of abnormal to normal findings between the both aged groups. The frequency of osseous abnormalities was similar with that of abnormalities of condylar position. Abnormalities in CP and JS were most frequent in all aged groups. Conclusion : There is no significant difference between ages or genders for temporomandibular joint radiographic abnormalities.

  • PDF

Medical decision making tools : Bayesian analysis and ROC analysis (의학적 의사결정 도구들에 대한 고찰 : Bayesian analysis and ROC analysis)

  • Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • During the diagnostic process of the various oral and maxillofacial lesions, we should consider the following: 'When should we order diagnostic tests? What tests should be ordered? How should we interpret the results clinically? And how should we use this frequently imperfect information to make optimal medical decisions?' For the clinicians to make proper judgement, several decision making tools are suggested. This article discusses the concept of the diagnostic accuracy (sensitivity and specificity values) with several decision making tools such as decision matrix, ROC analysis and Bayesian analysis. The article also explain the introductory concept of ORAD program.

  • PDF