Park, Kwonoh;Lim, Hyoung Gun;Hong, Ji Yeon;Song, Hunho
Journal of Hospice and Palliative Care
/
v.17
no.3
/
pp.179-184
/
2014
Purpose: We investigated the safety and efficacy of peripherally inserted central catheters (PICCs) in terminally ill cancer patients. Methods: A retrospective review was conducted on patients who underwent PICC at the hospice-palliative division of KEPCO (Korea Electric Power Corporation) Medical Center between January 2013 and December 2013. All PICCs were inserted by an interventional radiologist. Results: A total of 30 terminally ill cancer patients received the PICC procedure during the study period. Including one patient who had had two PICC insertions during the period, we analyzed a total of 31 episodes of catheterization and 571 PICC days. The median catheter life span was 14.0 days (range, 1~90 days). In 25 cases, catheters were maintained until the intended time (discharge, transfer, or death), while they were removed prematurely in six other cases (19%; 10.5/1000 PICC days). Thus, the catheter maintenance success rate was 81%. Of those six premature PICC removal cases, self-removal due to delirium occurred in four cases (13%; 7.0/1000 PICC days), and catheter-related blood stream infection and thrombosis were reported in one case, each (3%; 1.8/1000 PICC days). Complication cases totaled eight (26%; 14.1/1000 PICC days). The time to complication development ranged from two to 14 days and the median was seven days. There was no PICC complication-related death. Conclusion: Considering characteristics of terminally ill cancer patients, such as a poor general condition, vulnerability to trivial damage, and a limited period of survival, PICC could be a safe intravenous procedure.
Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.
Purpose: We evaluated the diagnostic value of $^{18}F-FDG$ PET/CT (PET/CT) in lymph node staging of non-small cell lung cancer (NSCLC) considering calcification and histologic types as well as FDG uptake. Materials and Methods: Fifty-three patients (38 men, 15 women; mean age, 62 years) with NSCLC underwent surgical resection (tumor resection and lymph node dissection) after PET/CT. After surgery, we compared PET/CT results with the biopsy results, and analyzed lymph node metastases, based on histologic types. PET diagnosis of lymph node metastasis was determined by maximum SUV (maxSUV) > 3.0, and PET/CT diagnosis was determined by maxSUV > 3.0 without lymph node calcification. Results: By PET diagnosis, the sensitivity, specificity, and accuracy of overall lymph node staging were 45% (13 of 29), 91% (228 of 252), and 86% (241 of 281). Specificity was 91% in both squamous cell carcinoma and adenocarcinoma, while sensitivity was 71% in squamous cell carcinoma and 36% in adenocarcinoma. When we excluded calcified lymph node with maxSUV > 3.0 from metastasis by PET/CT diagnosis, specificity improved to 98% in squamous cell carcinoma and 97% in adenocarcinoma. The degree of improvement was not dependent on histologic types. Conclusion: PET/CT improved specificity of lymph node staging by reducing false positive lymph node regardless of histologic types of NSCLC.
Lee, Gun;Lim, Chang-Young;Kim, Man Deuk;Lee, Hyeon-Jae
Journal of Chest Surgery
/
v.42
no.1
/
pp.53-58
/
2009
Background: The goal of this study was to compare the patency and complications of femoropopliteal bypass with superficial femoral artery stenting for patients with atherosclerotic superficial femoral artery occlusive disease. Material and Method: Between July 2005 and July 2008, we reviewed 29 femoropopliteal bypass procedures (24 patients) with prosthetic grafts (the bypass group) and 19 superficial femoral artery stentings (15 patients) with nitinol stent (the stent group). There were 35 male patients (89.7%) and the mean age of the patients was 69.2 years (range: 48~84). The number of patients who had DM, hypertension and a smoking history was 25 patients (64.1%), 17 patients (43.6%) and 30 patients (76.9%), respectively. 23 (59.0%) patients had skin ulceration or tissue gangrene at admission. Result: There were 27 cases (93.0%) of TASC C&D lesion in the bypass group and 16 cases (84.2%) of TASC A&B lesion in the stent group. There were significant differences for the indications for a procedure between the two groups (p<0.01). The primary patency rates at 6 months, 12 months and 24 months were 91.9%, 79.7% and 79.7% for the bypass group and 93.3%, 86.2% and 86.2% for the stent group, respectively. There were no statistical difference between the two groups (p=0.48). Conclusion: There were no significant differences in the outcome between two groups. TASC C&D lesion and failed intervention therapy should be treated with femoropopliteal bypass surgery, and TASC A&B lesion and the high-risk patients should be treated with femoral artery stent insertion.
Hur, Yun Jung;Lee, Joon Soo;Lee, Jong Doo;Kim, Heung Dong
Clinical and Experimental Pediatrics
/
v.51
no.3
/
pp.286-292
/
2008
Purpose : We performed EEG and PET on children with epilepsy concomitantly in order to evaluate the effects of epileptiform and non-epileptiform discharge of EEG on glucose metabolism. Methods : Seventy three children with epilepsy who had PET and EEG simultaneously were included in our study. The subjects were classified in two ways: (1) based on the frequency of epileptiform discharge and (2) the severity of non-epileptiform discharge. We evaluated the clinical aspects of their seizures, the severity of focal slow waves during the interictal period with the frequency of spikes or sharp waves in order to compare with the PET results. Results : The subjects were divided by the frequency of epileptiform discharge, with 13 in the no/rare group, 7 in the occasional group, and 53 children in the frequent group. The concordant rates with PET in each group were 0%, 42.9%, and 67.9%, respectively, showing high correlations with the frequency of epileptiform discharge (P<0.05, r=0.491). The subjects as divided by the severity of non-epileptiform discharge were 15 in the no group, 25 in the infrequent group, 17 in the intermediate group, and 16 in the continuous group. The concurrence rates with PET for each group were 13.3%, 52.0%, 64.7%, and 68.8%, respectively, also showing a high correlation with the severity of non-epileptiform discharge (P<0.05, r= 0.365). Conclusion : Epileptiform discharge and non-epileptiform discharge in EEG showed a certain association with hypometabolism in PET. We recommend EEG to reduce false lateralization and to localize lesions in cases of high frequency and severity.
Shim, Yoon Hee;Cho, Su Jin;Rhyu, Jung Hyun;Hong, Young Mi
Clinical and Experimental Pediatrics
/
v.48
no.10
/
pp.1082-1089
/
2005
Purpose : Abdominal obesity is encountered as a risk factor for cardiovascular diseases. However, the anthropometric cut-off value to estimate the cardiovascular risk, has not been suggested. This study was designed to find the relationship between the abdominal fat and various parameters of obesity to find the cardiovascular risk factors related to abdominal obesity and to establish practical methods to measure them. Methods : Twenty seven obese Korean adolescents of moderate to severe degree and 22 healthy adolescents were enrolled. The body mass index(BMI), arm circumference and skinfold thickness were measured. Furthermore, blood lipid, sugar, insulin and four different cytokines' levels were checked and the distribution of body composition was measured by bioelectrical impedance analysis. The subcutaneous and intra-abdominal fat thickness by abdominal ultrasonography(US) and the total and intra-abdominal fat area by abdominal computerized tomography(CT) were measured in the obese group. Results : The most accurate method to measure abdominal fat in children is abdominal CT and the fat mass measured by bioelectrical impedance was strongly correlated with it(r=0.954). It was also correlated with arm circumference, fat thickness measured by abdominal US, BMI, aspartate aminotransferase(AST), alanine aminotransferase(ALT) and triglyceride level. Conclusion : Abdominal CT is the most accurate method to measure intra-abdominal fat, and it can be replaced by abdominal US for cost effectiveness. The screening methods that can be used at school or in outpatient basis include bioelectrical impedance, waist/hip ratio, and arm circumference. The cardiovascular risk factors include leptin, triglyceride and insulin level.
This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.
Studies for diagnostic analysis using three-dimensional (3D) CT images are recently in progress and needs for 3D craniofacial analysis are increasing in the fields of orthodontics. It is especially essential to analyze the facial soft tissue after orthodontic treatment and orthognathic surgery. In this study 3D CT images of adults with normal occlusion were taken to analyze the facial soft tissue. Norms were obtained from CT images of adults with normal occlusion (12 males, 11 females) using a computer program named V works 4.0 program. 3D coordinate planes were established using soft tissue Nasion as the reference point and a total of 20 reproducible landmarks of facial soft tissue were obtained using the multiple reconstructive sectional images (axial, sagittal and coronal images) of the V works 4.0 program: soft tissue Nasion, Pronasale, Subnasale, Upper lip center, Lower lip center, soft tissue B, soft tissue Pogonion, soft tissue Menton, Endocanthion (Rt/Lt), Alare lateralis (Rt/Lt), Cheilion (Rt/Lt), soft tissue Gonion (Rt/Lt), Tragus (Rt/Lt), and Zygomatic point (Rt/Lt). According to the established landmarks and measuring method, the 3D CT images of adults with normal occlusion were measured and the normal positional measurements and their Net (${\delta}=\sqrt{{X^2}+{Y^2}+{Z^2}}$) values were obtained using V surgery program, In the linear measurement between landmarks, there was a significant difference between males and females except Na' -Sn and En(Rt)-En(Lt). The normal ranges of Na'-Zy, Na'-Ch and Na'-Go' (facial depth) were obtained, which was difficult to measure by two-dimensional (2D) cephalometric analysis and facial photographs. These data may be used as references for 3D diagnosis and treatment planning for patients with malocclusion and dentofacial deformity.
Objective: The purpose of this study was to examine how the mesio-distal angulation and the length of each tooth changes on panoramic radiograph at different bucco-lingual inclinations. Methods: After constructing an acrylic model based on the mean arch of 30 adults with normal occlusion, the wire was placed in the center of the teeth on the acrylic model. First, the wire was implanted in normal angulation and inclination and a panoramic radiograph taken. After changing the inclination from $I-5^{\circ}\;to\;I+15^{\circ}\;by\;5^{\circ}$, a panoramic radiograph was taken again and the mesio-distal angle and wire length on the panoramic radiograph were assessed. Results: When the wire was implanted at the normal angulation and inclination, the length measured in the panoramic radiograph was magnified $111{\sim}117%$ from the original length in the anterior region and $121{\sim}125%$ in the posterior region. Only the central and lateral incisors showed significant length differences when the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$ at fixed angulation. When the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$, the angulation of most teeth on panoramic radiograph appeared to be more disto-angulated than in reality, and the lateral incisor and canine showed the largest difference. Only $l-15^{\circ}\;to\;I+15^{\circ}$ groups of premolars and $I+15^{\circ}$ group of molars showed more mesio-angulation than in reality. As the labio(bucco)lingual inclination of all teeth were decreased, tooth angulation in the panoramic radiograph appeared to be more disto-angulated. Conclusion: The labio-liugual inclination of teeth should be considered because it affects panoramic image of teeth, such as length of incisors and angulation of other teeth.
There are currently many research papers on the knowledge, perceptions and actions of radiation-related staff, but hardly any papers on radiation major students in college who are to be staff members of radiation related jobs in the future. It is of course important to understand the perceptions of staff working on the lines and change their knowledge and perceptions, but in the long term it seems more efficient to understand those who are in the stage of being educated to be staff members-their knowledge and perception of radiation so that ultimately they can attain the right kind of understanding. Therefore the aim of this study is to grasp the pre-radiation staff's basic concept of radiation and space dose, their understanding of radiation safety based on this, and whether there is a change in their perception before and after the space dose measurement experiment; in the end this is to see if the space dose measurement experiment is effective in changing perception on radiation safety. This study took as its subject 64 students majoring radiation in college, I.e. pre-radiation staff members, and gauged their basic conceptualization of radiation, understanding of space dose, and understanding of radiation safety; in the X-ray room within the department the students were asked to measure space dose for themselves, so as to see whether there was a change in their understanding of radiation safety before and after the experiment, according to their understanding of the basic concept of radiation and of space dose. As a result of the space dose measurement experiment, students' increased basic knowledge of concept of radiation and understanding of the dangers of space dose were noteworthy, and accordingly their understanding of radiation safety became stricter and more conservative. In spite of this, their work ethic stayed in the lead of their understanding of radiation safety; this implies the need of a more departmentalized safety education program. Therefore instead of safety education that simply uses visual-audial material in a kind of lecture, I suggest here that there be a more experiential safety education program that enables learners to try out space dose measurement experiments for themselves, a work ethic education that aims for a conventional point of view towards radiation safety as well as a stern attitude.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.