• Title/Summary/Keyword: Radiology Department

Search Result 9,028, Processing Time 0.035 seconds

Apoptosis and Proliferative Activity of Non-Hodgkin's Lymphoma : Correlation with Bcl-2 and P53 Protein Expression (비호지킨림프종에서 아포프토시스 및 세포증식 : Bcl-2, P53 단백발현과의 관계)

  • Oh, Yoon-Kyeong;Lee, Mi-Ja;Jeon, Ho-Jong
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2002
  • Purpose : Tumor growth in a given neoplasm is the net result of cell proliferation and cell loss, and apoptosis is the most significant component of continuous cell loss in most tumors. In this study, we examined non-Hodgkin's lymphoma (NHL, n=67) immunohistochemically for the presence of Bcl-2 oncoprotein and P53 protein and compared apoptotic indices (Als) and Ki-67 proliferative indices (percentages of Ki-67 positive cells). Materials and Methods : 67 patients with NHL were evaluated : 3 low-grade and 64 intermediate-grade. The phenotype was determined in 65 cases : 47 $(70\%)$ were B cell type and 18 $(27\%)$ were T ceil type. Als and Ki-67 proliferative indices were determined immunohistochemically and the overexpression of P53 and Bcl-2 protein were also evalutated. Results : The overexpressions of Bcl-2 protein and P53 protein were found in $40\%$ (26/65) and $31\%$ (20/65). The Al ranged from $0\%\;to\;15\%$ (mean 2.16, median 1.2). Cellular Bcl-2, which counteracts apoptosis, was significantly (p=0.005) associated with Als. Ki-67 proliferative indices ranged from $1\%\;to\;91\%$ (mean 55.4), and P53 was significantly (p=0.000) associated with Ki-67 proliferative indices. A positive correlation between Als and Ki-67 proliferative indices was revealed (p=0.012) in Bcl-2 positive patients. Conclusion : In NHL, we observed a correlation between Als and Bcl-2 expression, between Ki-67 proliferative indices and P53 expression, and between Als and Ki-67 proliferative indices in Bcl-2 positive patients. Our results suggest that cell apoptosis may be inseparable from cell proliferation during tumor growth.

The Usefulness of Measurement of Whole Body Count in Assessing Bone Marrow Metastasis in Cancer Patients with Increased Periarticular Bone Uptake on Follow-up Bone Scan: A Comparison with Bone Marrow Scan (암환자의 추적 골스캔에서 관절주위 섭취증가시 전신골섭취계수 측정이 골수전이 평가에 도움이 되는가-골수스캔과의 비교)

  • Jin, Seong-Chan;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.428-436
    • /
    • 2003
  • Purpose: Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Materials and methods: Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Results: Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung cacner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Conclusion: Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases.

A Study of Factors Affecting Measurement of Kidney Size in Ultrasonography (초음파로 신장의 크기 측정 시 미치는 영향에 관한 연구)

  • Yoon, Seok-Hwan;Kim, Yun-Min;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Since measuring the size of kidney with sonography becomes an important index for diagnosis, treatment, and prognostic prediction in kidney disease, the accurate measurement and evaluation on this are clinically very important. Accordingly, the purpose of this study was to increase reproducibility and objectivity in measuring the size of kidney by enumerating factors that have an impact for measurement. It targeted 44 adults in Korea at the age of 21-27. It measured in order for both kidneys to be seen most largely while changing a subject-examiner's position in a state of fasting for 8 hours and a transducer's approaching direction. It compared a size of kidney by measuring, respectively, with the same method in 30 minutes and in 1 hour after drinking water in 700-1,000cc. In case of the lateral approach scan in decubitus position, the average length of the kidney both to the right and the left and the deviation of measurement to be the largest. In NPO(None Per Oral) state, the average length in the right kidney was 10.19cm, and the average length in the left kidney was 10.33cm. In 60 minutes after taking moisture, the average length in the right kidney was 10.94cm, and the average length in the left kidney was 11.13cm. In comparing the average length of the kidney in NPO state and its average length in 60 minutes after taking moisture, the size swelled by 7.3% for the length in the right kidney and by 7.7% in the left, thereby having been indicated to be statistically significant(P<0.003). The measurement in a size of kidney by using ultrasound may be measured differently depending on a patient's state of taking moisture and a transducer's approaching direction. It is thought that when the measurement in a size of kidney is especially important clinically, the intake and intake time in moisture need to be considered and that measuring with the posterior approach in prone position is a good method aiming to increase reproducibility in measuring length of the kidney.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

The Effects of Steroid on Acute Lung Injury in the Mouse Induced by Whole Lung Irradiation (전폐조사로 유발된 마우스의 급성폐손상에 대한 스테로이드의 효과)

  • Sung, Nak-Kwan;Shin, Sei-One;Kwon, Kun-Young
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.37-47
    • /
    • 1997
  • Purpose : To investigate ultrastructural changes of the mouse lung induced by whole lung gamma irradiation and to evaluate the effect of prophylactic administration of steroid against acute lung injury. Materials and Methods :. One hundred and twenty ICR mice were used and whole lung was irradiated with telecobalt machine. Whole lung doses were 8 and 12Gy, and 10mg of methyl prednisolone was administrated intraperitoneally for two and four weeks. At the end of the observation period, mice were sacrificed by cervical dislocation. The lungs were removed and fixed inflated. Histopathological examination of acute radiation injuries were Performed by light microscopic and transmission electron microscopic examination. Results : Control group with BGy is characterized by damage to the type I Pneumocyte and the endothelial cell of the capillary. edema of alveolar wall and interstitium. and fibroblast proliferation. Control group with 120y is characterized by more severe degree of type 1 pneumocyte damage and more prominant inflammatory cell infiltration. Destructed cell debris within the alveolar space were also noted After steroid administration, 8Gy experimental group showed decreased degree of inflammatory reactions but fibroblast proliferation and basal lamina damages were unchanged. Experimental group with 12Gy showed lesser degree of inflammatory reactions similar to changes of 8Gy experimental group. Conclusion : These studies suggest that the degree of interstitial edema and inflammatory changes were related to radiation dose but Proliferation of the fibroblast and structural changes of basal lamina were not related to radialion dose. Experimental administration of steroid for 2 to 4 weeks after whole lung irradiation suggest that steroid can suppress alveolar and endothelial damages induced by whole lung irradiation but Proliferation of the fibroblast and structural changes of basal lamina were not related to administration of steroid.

  • PDF

Effects of Locus Coeruleus/Subcoeruleus Stimulation on the Tail Flick Reflex and Efflux of Noradrenaline into the Spinal Cord Superfusates (청반핵 자극으로 인한 노르아드레날린의 유리가 동통의 조절에 미치는 영향)

  • Park, Kyung-Pyo;Kim, Jong-Sung;Suh, Dae-Chul;Park, Hyoung-Sup
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.1
    • /
    • pp.29-37
    • /
    • 1994
  • Inhibition of the nociceptive Tail Flick Reflex (TFR) was observed with electrical stimulation of the locus coeruleus/subcoeruleus (LC/SC) in the male Sprague - Dawley rats under light anesthesia, and the involved neurotransmitter (s) were characterized. Electrical stimulation of LC/SC induced the analgesia with the stimulation threshold (intensity of the current, given for 100 usec and in 100 Hz frequency, which caused the TF latency longer than 6.5 sec) around 55 uA. Intrathecal administrations of ${\alpha}_2$ antagonist, yohimbine (30 ug) or opioid antagonist, naloxone (20 ug) increased the stimulation threshold by 147% and 123% respectively (from 55 uA to 135 uA,9 and from 54 uA to 123 uA;P0.01, n=5, each). The basal TF latency without stimulation (3.1 sec) was reduced by the antagonists (to 2.5 sec by yohimbine, p<0.05, n=5; to 2.6 sec by naloxone, p<0.1, n=5), vehicle only did not show any effect. Noradrenaline(NA) in the spinal cord superfusates measured with HPLC was increased by the LC/SC stimulation, from 4.18 ng/ml before to 7.74 ng/ml after stimulation (P<0.05, n=10). The result suggest that analgesia induced by LC/SC stimulation is mediated, at least in part, by the noradrenergic system in which ${\alpha}_2$ receptor is involved, as well as the opioid system.

  • PDF

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF

Omental Infarction Following Laparoscopy-assisted Gastrectomy (LAG) for Gastric Cancer (위암 환자의 복강경 위절제술 후 발생한 그물막 경색의 임상적 의의)

  • Kim, Min-Chan;Jung, Ghap-Joon;Oh, Jong-Young
    • Journal of Gastric Cancer
    • /
    • v.10 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose: Omental infarction (OI) following laparoscopy-assisted gastrectomy (LAG) for gastric cancer could become more common in the future because the indications for LAG are expected to expand. The aim of this study was to determine the clinical characteristics of OI following LAG. Materials and Methods: Three hundred ninety patients who underwent LAG for T1 or T2 gastric cancer from April 2003 to November 2007 were enrolled. OI was diagnosed by two radiologists using the patients' abdominal 16 row-detector CT scans. The clinicopathologic characteristics were retrospectively evaluated in the omental infarction (OI) group and the non-omental infarction (non-OI) group using the gastric cancer database of Dong-A University Medical Center and the medical record. Results: Nine omental infarctions (2.3%) of 390 LAGs were diagnosed. All the OIs could be discriminated from omental metastasis on the initial or follow up CT images. The location of the omental infarctions was on the epigastrium in 3 patients and in the left upper quadrant in 3 patients. The mean size of the OIs was 4.1 cm. Most patients with OI had no signs or symptoms. The body mass index of the OI group was higher than that of the non-OI group (P=0230), and OI was more common in patients who underwent total gastrectomy than in the patients who underwent subtotal gastrectomy (P=0.0011). Conclusion: Laparoscopy-assisted gastrectomy (LAG) with partial omentectomy for gastric cancer can be a cause of secondary OI. Omental infarction after LAG has different clinical characteristics and CT findings that those of other omental infarctions or postoperative omental metastases. Further multicenter study will be needed to evaluate in detail the clinical features of omental infarction after LAG.