• Title/Summary/Keyword: Radiology Department

Search Result 9,028, Processing Time 0.036 seconds

The Trend of Change in Oral and Maxillofacial Injuries of Pediatric Patients in the COVID-19 Pandemic: a Regional Emergency Medical Center and Dental Hospital Study (COVID-19 팬데믹 상황에서 소아 환자의 구강악안면 외상의 변화 추이: 단일 기관 연구)

  • Suebin Choi;Chankue Park;Jonghyun Shin;Taesung Jeong;Eungyung Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.318-333
    • /
    • 2023
  • The purpose of this study is to analyze changes in dental trauma in children under the age of 12 during the period of Coronavirus Disease 2019 (COVID-19). March 2020, when COVID-19 was officially declared a pandemic by the World Health Organization, was set as the starting point for COVID-19. From March 2018 to February 2020, subjects in the pre-COVID-19 period were classified as the Pre-COVID-19 group, and from March 2020 to March 2022, subjects in the post-COVID-19 period were classified as the COVID-19 group. Information related to trauma was collected through electronic medical records. The number of trauma patients before and after the outbreak of COVID-19 decreased significantly. During the COVID-19 period, there was no significant difference in the male-female ratio or the distribution order of age groups. In the COVID-19 group of permanent teeth, the ratio of trauma caused by personal mobility was higher than trauma caused by sports. In the COVID-19 group of permanent teeth, the ratio of crown fracture with pulp involvement was significantly higher than the ratio of crown fracture without pulp involvement. Changes in trauma patterns caused by COVID-19 were observed more clearly in school-aged children than in preschool children. In a pandemic situation such as COVID-19, it is expected to be used as a good educational basis for knowing that frequent diagnoses can change due to changes in the environment.

Ameliorative Effects of Soybean Leaf Extract on Dexamethasone-Induced Muscle Atrophy in C2C12 Myotubes and a C57BL/6 Mouse Model (콩잎 추출물의 근위축 개선 효과)

  • Hye Young Choi;Young-Sool Hah;Yeong Ho Ji;Jun Young Ha;Hwan Hee Bae;Dong Yeol Lee;Won Min Jeong;Dong Kyu Jeong;Jun-Il Yoo;Sang Gon Kim
    • Journal of Life Science
    • /
    • v.33 no.12
    • /
    • pp.1036-1045
    • /
    • 2023
  • Sarcopenia, a condition characterized by the insidious loss of skeletal muscle mass and strength, represents a significant and growing healthcare challenge, impacting the mobility and quality of life of aging populations worldwide. This study investigated the therapeutic potential of soybean leaf extract (SL) for dexamethasone (Dexa)-induced muscle atrophy in vitro and in an in vivo model. In vitro experiments showed that SL significantly alleviated Dexa-induced atrophy in C2C12 myotube cells, as evidenced by preserved myotube morphology, density, and size. Moreover, SL treatment significantly reduced the mRNA and protein levels of muscle RING-finger protein-1 (MuRF1) and muscle atrophy F-box (MAFbx), key factors regulating muscle atrophy. In a Dexa-induced atrophy mouse model, SL administration significantly inhibited Dexa-induced weight loss and muscle wasting, preserving the mass of the gastrocnemius and tibialis anterior muscles. Furthermore, mice treated with SL exhibited significant improvements in muscle function compared to their counterparts suffering from Dexa-induced muscle atrophy, as evidenced by a notable increase in grip strength and extended endurance on treadmill tests. Moreover, SL suppressed the expression of muscle atrophy-related proteins in skeletal muscle, highlighting its protective role against Dexa-induced muscle atrophy. These results suggest that SL has potential as a natural treatment for muscle-wasting conditions, such as sarcopenia.

The Results of Hyperfractionated Radiotherapy on Locally Advanced Non-Small Cell Lung Cancer (국소적으로 진행된 비소세포 폐암에 대한 과분할 방사선 치료의 성적)

  • Hur, Won-Joo;Lee, Hyung-Sik;Kim, Jeong-Ki;Choi, Young-Min;Lee, Ho-Jun;Youn-Seon-Min;Kim, Jae-seok;Kim, Hyo-Jin;Woo-Jong-Soo;Choi, Pill-Jo;Lee, Ki-Nam
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.275-282
    • /
    • 1998
  • Purpose : The effect of hyperfractionated radiotherapy on locally advanced non-small lung cancer was studied by a retrospective analysis. Materials & Methods : We analyzed sixty one patients of biopsy-confirmed, IIIA and IIIB non-small cell lung cancer. Using the ECOG performance scale, all the patients were scored less than 2. They were treated by curative hyperfractionated radiotherapy alone from Oct. 1992 to Oct. 1995 at the Department of Radiation Oncology. All the patients received 120cGy b.i.d with more than 6 hours interval between each fraction. The total dose of radiation was reached up to 6400-7080 cGy with a mean dose of 6934 cGy. The results were analyzed retrospectively. Results : The overall survival rate was 53 1$\%$ in 1 year, 9.9$\%$ in 2 years with a median survival time (MST) of 13.9 months. The progression free survival (PFS) rate was 37.0$\%$ in 1 year, 8.9$\%$ in 2 years. Twenty two Patients were classified as complete responders to this treatment and their MST was 19.5 months When this was compared with that of partial responders (MST: 11 7months), it was statistically significant (p=0.0003). Twenty nine patients of stage IIIA showed a better overall survival rate (1yr 63.3$\%$, 2yr 16.8$\%$) than IIIB patients (1yr 43.3$\%$, 2yr 3.6$\%$), which was also statistically significant (p=0.003). Patients with adenocarcinoma showed a better survival rate (1yr 64.3$\%$, 2yr 21.4$\%$) than that of squamous cell counterpart (1yr 49.4$\%$, 2yr 7.4$\%$), although this was not significant statistically (p=0.61). Two patients developed fatal radiation-induced pneumonia right after the completion of the treatment which progressed rapidly and they all died within 2 months. One patient developed radiation-induced fibrosis after 13 months. He refused further treatment and died soon after the development of fibrosis. Conclusion : Among locally advanced NSCLC, hyperfractionated radiotherapy was effective on stage IIIA patients by increasing MST with acceptable toxicities. Acute radiation-induced pneumonia should be carefully monitored and must be avoided during or after this treatment.

  • PDF

Minimized Radiation Dose of Patients Receiving High Dose Radioiodine(I-131) Therapy (고용량 방사성옥소(I-131) 치료환자의 피폭선량 저감화 연구)

  • Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.435-442
    • /
    • 2007
  • The number of thyroid diseases treated with radioiodine(I-131) is increasing steadily. The sharp increase in patients who require high dose radioiodine therapy greatly increased the need for new therapy rooms. Accordingly, interest in radiation exposure is rising as well, and is a major psychological stress factor for the patient and those who come in close contact with the patient. This study aimed to minimize the radiation exposure on discharge. Based on various previous reports, the decision for discharge should be individualized depending on many factors related to the patient's living or working environment. Educating patients repeatedly on the importance of sufficient oral hydration, while the adequate amount was relative to the patient's individual condition, greatly lowered the detected radiation measurement within the same admission period. In some cases, the period of admission could be abbreviated.

  • PDF

The Precaution Duty and the Product Liability for Adverse Reactions to the Contrast Media (조영제 부작용에 대한 주의의무와 제조물책임)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.305-311
    • /
    • 2007
  • Contrast medium is a useful drug for radiological examinations and usability of it gradually increases while it has some inevitable adverse reaction and it is difficult to predict the occurrence and the degree of adverse reactions. Although the patient consented permission for the use of contrast media, the hospital could not be exempted from the responsibility for the adverse contrast media reaction. During radiological contrast media examination, the radiologist and the contrast media producer have the duty of precaution, prediction and avoid adverse results. In addition, they have reliabi lity of patient remedy for neglecting the duty. Since contrast medium are manufactured or processed as movable properties, the manufacturers are bound to the product liability if damages occur due to the defects in pharmaceuticals. In consideration of the characteristics of product liability, it is necessary to demand high degree of duty of care and diligence from producer or to reduce patient's burden of proof in a product liability lawsuit. For securing compensation ability and liability implementation, products compensation liability insurance is required for contrast medium manufacturers. In conclusion, contrast medium producer has legal liability for adverse reactions and the contract concluded with producer and hospital including legal liability will reduce liability of hospital and radiologist, patient.

  • PDF

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

Ultrasonographic and Magnetic Resonance Imaging Findings of Testicular Lymphoma (고환림프종의 초음파검사 및 자기공명영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.105-112
    • /
    • 2010
  • Purpose : To evaluate the specific radiologic findings of testicular lymphoma which will be able to differentiated from other testicular tumors. Materials and Methods : Pathologically confirmed eight cases were included in this study. All eight cases were performed ultrasonography and four cases were performed magnetic resonance image. On ultrasonography, the size, location, shape, margin, internal echogenicity, homogeneity and vascularity were evaluated. On magnetic resonance image, the shape, margin, homogeneity, signal intensity on T1- and T2-weighted images, degree and homogeneity of the contrast enhancement and contrast enhancement change on dynamic enhancement study. Results : The margin of the mass was smooth on 6 of 8 patients. Internal echogenicity of the mass lesion was hypoechoic than normal testicular parenchyme on 7 of 8 patients. Four cases were homogeneous, 3 cases were relatively homogeneous and 1 case was heterogeneous. All 8 cases showed increased vascularity. The mass lesion was iso-signal intensity on T1-weighted image and low-signal intensity on T2-weighted image. All four cases were enhanced homogeneously and mildly than enhancing normal testicular parenchyme. On dynamic enhancement study, the mass lesion is progressively enhanced with time. Conclusion : The possibility of testicular lymphoma should be considered when testicular mass was homogeneously hypoechoic and low signal intensity on T2-weighted image in old age patients.

  • PDF

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

Effects of Korean Red Ginseng on White Matter Microstructure and Cognitive Functions : A Focus on Intrusion Errors (고려 홍삼이 대뇌 백질 미세구조 및 인지기능에 미치는 효과 : 침입 오류를 중심으로)

  • Jeong, Hyeonseok S.;Kim, Young Hoon;Lee, Sunho;Yeom, Arim;Kang, Ilhyang;Kim, Jieun E.;Lee, Junghyun H.;Ban, Soonhyun;Lim, Soo Mee;Lee, Sun Hea
    • Korean Journal of Biological Psychiatry
    • /
    • v.22 no.2
    • /
    • pp.78-86
    • /
    • 2015
  • Objectives Although ginseng has been reported to protect neuronal cells and improve various cognitive functions, relationship between ginseng supplementation and response inhibition, one of the important cognitive domains has not been explored. In addition, effects of ginseng on in vivo human brain have not been investigated using the diffusion tensor imaging (DTI). The purpose of the current study is to investigate changes in intrusion errors and white matter microstructure after Korean Red Ginseng supplementation using standardized neuropsychological tests and DTI. Methods Fifty-one healthy participants were randomly allocated to the Korean Red Ginseng (n = 26) or placebo (n = 25) groups for 8 weeks. The California Verbal Learning Test was used to assess the number of intrusion errors. Intelligence quotient (IQ) was measured with the Korean Wechsler Adult Intelligence Scale. Depressive and anxiety symptoms were evaluated using Hamilton Depression Rating Scale, Hamilton Anxiety Rating Scale, and Hopkins Symptom Checklist-25. The fractional anisotropy (FA) was measured from the brain DTI data. Results After the 8-week intervention, Korean Red Ginseng supplementation significantly reduced intrusion errors after adjusting age, sex, IQ, and baseline score of the intrusion errors (p for interaction = 0.005). Change in FA values in the left anterior corona radiata was greater in the Korean Red Ginseng group compared to the placebo group (t = 4.29, p = 0.04). Conclusions Korean Red Ginseng supplementation may be efficacious for improving response inhibition and white matter microstructure integrity in the prefrontal cortex.

A Study on the Measurement of Bacterial Contamination of MRI Examination Equipment and Disinfection Conditions (자기공명영상검사장비의 세균오염도 측정 및 소독에 관한 연구)

  • Jeung, Seung-Woon;Lim, Chung-Hwan;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.665-672
    • /
    • 2013
  • In radiology department, where patients with a variety of diseases receive their tests, there is a large possibility of cross contamination of nosocomial infection. Magnetic resonance imaging (MRI) tests take particularly more time than other tests do, which increases the possibility of being exposed to cross contamination. Therefore, this research examines the status of MRI equipment sterilization and investigates the bacterial distribution on head coils, which have the most frequent contact with patients, patient fixation blocks, and bores, which are confined spaces. The status of MRI equipment disinfection was examined by a survey targeting 150 employees, and the distribution of bacteria was measured in ten medical facilities. The result of bacterial distribution tests on MRI equipment showed various bacteria, including Staphylococcus, Acinetobacter, Sphingomona, Pantoea agglomeranss, Micrococcus, Bacillus, Saprophyticus, Brevundimona, and Myroidesspecies. The result of examining the stat us of MRI room disinfection showed that the disinfections of the head coil, block, and bore were implemented well, and the largest proportion was carried out once a day in the morning. The time and implementation of disinfection by the disinfection manager showed that they were implemented well when the manager was the MRI room examiner. The disinfection after examining a patient using an appropriate disinfectant is mandatory to prevent cross contamination.