• 제목/요약/키워드: Radiology Department

검색결과 9,255건 처리시간 0.032초

The influence of X ray beam angulation on the fractal analysis of trabecular architecture in human dry mandible using standardized tile counting method

  • Lee Kyung-Hee;Lee Sun-Bok;An Chang-Hyeon;Heo Min-Suk;Yi Won-Jin;Huh Kyung-Hoe;Park Moo-Soon;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.179-182
    • /
    • 2004
  • Purpose: The purpose of this study is to examine the effects of X-ray beam angulation on the fractal dimension of trabecular bone structure of human dry mandible using the tile counting method. Materials and Methods: We divided 5 human dry mandibles into an angle and a molar groups depending on the regions and deciding the region of interest (ROI). When contrasted with the ROI, the inferior cortex was appointed to be low and the lines perpendicular to the buccal cortex were appointed to be the standard angle. Direct digital intraoral radiographs were obtained from 9 different projection angles. We analyzed statistically the fractal dimension using the tile counting method. Results: There was a statistically significant difference in the fractal dimension of the regions and the mandibles, but there was no statistically significant difference in the fractal dimension according to the X-ray beam angulation. Conclusion : There is no statistically significant effect of the angle of the projection on the fractal dimension of trabecular bone structure of a human dry mandible according to the tile counting method.

  • PDF

Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases

  • Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1066-1076
    • /
    • 2018
  • Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.

Anti-Myelin Oligodendrocyte Glycoprotein Syndrome with Findings Resembling "Snake-Eye Appearance": a Case Report

  • Hong, Sujin;Yi, Jisook;Lee, Ho-joon;Hahn, Seok;Lim, Yun-jung;Lee, Yedaun;Shin, Kyong Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.189-192
    • /
    • 2021
  • Anti-myelin oligodendrocyte glycoprotein (anti-MOG) syndrome is an immune-mediated inflammatory condition of the central nervous system, which usually involves spinal cord and optic nerves. Herein, we studied the case of a 57-year-old female patient who presented with acute/subacute symptoms of sphincter dysfunction, paraparesis, and ocular pain. The patient was diagnosed with anti-MOG syndrome with findings resembling snake-eye appearance (SEA), characterized by nearly symmetrical round high signal intensity lesions located at anterior horns (gray matter) on T2-weighted image.

Combining Non-Contrast CT Signs With Onset-to-Imaging Time to Predict the Evolution of Intracerebral Hemorrhage

  • Lei Song;Xiaoming Qiu;Cun Zhang;Hang Zhou;Wenmin Guo;Yu Ye;Rujia Wang;Hui Xiong;Ji Zhang;Dongfang Tang;Liwei Zou;Longsheng Wang;Yongqiang Yu;Tingting Guo
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.166-178
    • /
    • 2024
  • Objective: This study aimed to determine the predictive performance of non-contrast CT (NCCT) signs for hemorrhagic growth after intracerebral hemorrhage (ICH) when stratified by onset-to-imaging time (OIT). Materials and Methods: 1488 supratentorial ICH within 6 h of onset were consecutively recruited from six centers between January 2018 and August 2022. NCCT signs were classified according to density (hypodensities, swirl sign, black hole sign, blend sign, fluid level, and heterogeneous density) and shape (island sign, satellite sign, and irregular shape) features. Multivariable logistic regression was used to evaluate the association between NCCT signs and three types of hemorrhagic growth: hematoma expansion (HE), intraventricular hemorrhage growth (IVHG), and revised HE (RHE). The performance of the NCCT signs was evaluated using the positive predictive value (PPV) stratified by OIT. Results: Multivariable analysis showed that hypodensities were an independent predictor of HE (adjusted odds ratio [95% confidence interval] of 7.99 [4.87-13.40]), IVHG (3.64 [2.15-6.24]), and RHE (7.90 [4.93-12.90]). Similarly, OIT (for a 1-h increase) was an independent inverse predictor of HE (0.59 [0.52-0.66]), IVHG (0.72 [0.64-0.81]), and RHE (0.61 [0.54-0.67]). Blend and island signs were independently associated with HE and RHE (10.60 [7.36-15.30] and 10.10 [7.10-14.60], respectively, for the blend sign and 2.75 [1.64-4.67] and 2.62 [1.60-4.30], respectively, for the island sign). Hypodensities demonstrated low PPVs of 0.41 (110/269) or lower for IVHG when stratified by OIT. When OIT was ≤ 2 h, the PPVs of hypodensities, blend sign, and island sign for RHE were 0.80 (215/269), 0.90 (142/157), and 0.83 (103/124), respectively. Conclusion: Hypodensities, blend sign, and island sign were the best NCCT predictors of RHE when OIT was ≤ 2 h. NCCT signs may assist in earlier recognition of the risk of hemorrhagic growth and guide early intervention to prevent neurological deterioration resulting from hemorrhagic growth.

구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

TUMOR-INDUCED HYPOPHOSPHATEMIC OSTEOMALACIA -Report of a Case Associated with Peripheral Giant Cell GRANULOMA of Gingiva -

  • 이상래;김원철;이상훈;김미경;이병도
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.279-286
    • /
    • 1987
  • The authors observed a patient who referred to the Department of Oral Radiology, due to diffuse skeletal pain, muscular weakness and unknown tumor mass on the buccal gingiva of upper right molar region. The patient was found to have peripheral reparative giant cell granuloma and osteomalacia. After removal of the tumor, the clinical, radiologic, and laboratory findings of the patient was rapidly normalized with remarkable improvement of bone pain. The results were as follows: 1. After removal of the tumor, the patient improved. the clinical findings such as bone pain, trismus. muscular weakness and he could walk. 2. In postoperative x-ray findings at 1 and 2 months intervals, the lamina dura of all dentition and bony trabeculae in upper and lower arches were regenerating and the bone density increased. 3. In periodic recall check, no occurrence of osteomalacia was existed and the laboratory findings of the patient showed gradual improvement.

  • PDF

No-Touch Radiofrequency Ablation for Early Hepatocellular Carcinoma: 2023 Korean Society of Image-Guided Tumor Ablation Guidelines

  • Seungchul Han;Min Woo Lee;Young Joon Lee;Hyun Pyo Hong;Dong Ho Lee;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.719-728
    • /
    • 2023
  • Radiofrequency ablation (RFA) has been widely used to manage hepatocellular carcinomas (HCCs) equal to or smaller than 3 cm. No-touch RFA has gained attention and has recently been implemented in local ablation therapy for HCCs, despite its technical complexity, as it provides improved local tumor control compared to conventional tumor-puncturing RFA. This article presents the practice guidelines for performing no-touch RFA for HCCs, which have been endorsed by the Korean Society of Image-Guided Tumor Ablation (KSITA). The guidelines are primarily designed to assist interventional oncologists and address the limitations of conventional tumor-puncturing RFA with describing the fundamental principles, various energy delivery methods, and clinical outcomes of no-touch RFA. The clinical outcomes include technical feasibility, local tumor progression rates, survival outcomes, and potential complications.

Transcaval TIPS in Patients with Failed Revision of Occluded Previous TIPS

  • Chang Kyu Seong;Yong Joo Kim;Tae Beom Shin;Hyo Yong Park;Tae Hun Kim;Duk Sik Kang
    • Korean Journal of Radiology
    • /
    • 제2권4호
    • /
    • pp.204-209
    • /
    • 2001
  • Objective: To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Materials and Methods: Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Results: Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Conclusion: Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  • PDF