• Title/Summary/Keyword: Radiological reduction

Search Result 452, Processing Time 0.026 seconds

The Necessity of Coracoclavicular Ligament Repair in Open Reduction for the Acromioclavicular Joint Dislocations (견봉 쇄골 관절 탈구의 관혈적 정복술시 오구 쇄골 인대 봉합의 필요성)

  • Kim, Eu-Gene;Shin, Hun-Kyu;Jeong, Haw-Jae;Choi, Jae-Yeol;Park, Se-Jin;Choi, Kyu-Bo;Lim, Jong-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: We evaluated clinical and radiological results for open reduction and internal fixation of acromioclavicular dislocation without coracoclavicular ligament repair after removal of implants. Materials and methods: Clinical and radiological results were obtained for 53 patients who underwent open reduction and internal fixation of an acromioclavicular joint dislocation between 1998 and 2007. A total of 21 patients were treated with a modified-Phemister method and 32 patients were treated with a Hook plate method. All subjects were surveyed after removal of their implants. The Constant scoring system was administered postoperatively to evaluate clinical results. Radiologic outcomes were evaluated by both coracoclavicular intervals on plain films. Results: Constant scores were $87.59{\pm}7.8$ in the Phemister group and $89.35{\pm}5.3$ in the Hook plate group. For both groups, the mean coracoclavicular interval at preoperative radiography was 15.9 mm at the injured site and 8.0 mm at the opposite site. After metal removal, the mean difference between coracoclavicular distances between normal and injured sites were 1.0 mm for the Hook plate group and 1.2 mm for the modified Phemister method group (p>0.05). Conclusion: Open reduction and internal fixation of an acromioclavicular joint without coracoclavicular ligament repair shows good long-term clinical and radiological results.

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.

Clinical and Radiological Outcomes of Hook Plate Fixation in the Lateral End Fracture of the Clavicle and Acromioclavicular Dislocation

  • Min, Young Kyoung;Kim, Jung Han;Gwak, Heui Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • Background: The purpose of this study was to identify the clinical and radiological outcomes of hook plate fixation for lateral end fracture of the clavicle and acromioclavicular dislocation. Methods: There were a total of 20 cases with lateral end fracture of the clavicle and 16 cases with acromioclavicular dislocation. All patients were evaluated for range of motion, functional score by using Constant score, and American Shoulder and Elbow Surgeons shoulder index at just before implant removal and at final follow-up. Coracoclavicular distance was measured in acromioclavicular dislocation and bony union was evaluated in the lateral end fracture of the clavicle. Results: The clinical outcomes and range of motion were increased at the final follow-up compared with just before implant removal in both the lateral end fracture of the clavicle and acromioclavicular dislocation. In acromioclavicular dislocation, all cases-except one-showed maintenance of reduction after implant removal. Moreover, in the lateral end fracture of the clavicle, all cases-except one-showed bony union. Conclusions: Hook plate fixation in the lateral end fracture of the clavicle and acromioclavicular dislocation resulted in good clinical and radiological results.

Measurement of X-ray Quality in Mammography Unit (유방촬영용 X선장치의 선질 특성)

  • Lee, In-Ja;Kim, Jung-Min;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.5-10
    • /
    • 1998
  • In the mammography, X-ray beam quality is one of the most important factors. Using X-ray mammography unit model GE/CGR Senography 600T Senix H.F, Authors studied four subjects. 1. The aluminum attenuation rate in 30 kVp when used with or without compression plate. 2. HVLs at 5 different area of the X-ray field of $26{\sim}32kVp$. 3. HVLs to know the influence of corrected measurement or parallel measurement. 4. Film density with microdensitometer along and cross to the long axis of X-ray tube, in terms of the Heel effect in the X-ray field. The following results were obtained. 1. Beam quality of anode area was harder than cathode area. 2. The dose reduction rate of compression plate was approximately $65.5%{\sim}88.1%$ and the beam quality with compression plate was hardened up to 4kVp accordingly. 3. If the X-ray beam enters the attenuation plate obliquely, HVL was $2.6{\sim}2.9%$ harder than perpendicular to it. 4. Because of heel effect, the film density of cathode area is higher than anode area to film density of 0.5.

  • PDF

RABBIT HEATING BY MICROWAVE EXPOSURE AT VARIOUS AMBIENT TEMPERATURES

  • Kolganova, Olga I.;Zhavoronkov, Leonid P.;Petin, Vladislav G.;Kim, Jin-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.99-104
    • /
    • 2010
  • The potential ability of environmental temperature to enhance the effect of microwave radiation (7 GHz) was experimentally studied for rabbit heating after simultaneous application of both agents. The tested ambient temperatures (30 and $38^{\circ}C$) didn't exert a considerable influence upon rabbit heat homeostasis after the used duration of exposure (3 hours and 15 minutes, correspondingly). The synergistic interaction of microwave irradiation and ambient temperature was demonstrated for rabbit heating. Power flux density of microwave irradiation was shown to be a determinant of the synergistic interaction effectiveness. For the fixed ambient temperature ($30^{\circ}C$), the synergism was shown to be observed only within a definite power flux density ($0-100\;mW{\cdot}cm^{-2}$), inside of which there was an optimal intensity ($20\;mW{\cdot}cm^{-2}$), which maximized the synergistic effect. Any deviation of the power flux density from the optimal value resulted in a reduction of the synergy. It is concluded that any assessment of the health or environmental risks should take into account the synergistic interaction between ambient temperature and microwave radiation.

A Clinical Study on Liver Scanning using Colloidal Radiogold and Liver Function in Cirrhosis of the Liver (간경변증(肝硬變症)에 있어서 교질형방사성금(膠質形放射性金)($^{198}Au$)을 사용(使用)한 간(肝)스켄과 간기능(肝機能)과의 관계(關係)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Lee, Young;Min, Young-Eal;Hong, Changgi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.59-67
    • /
    • 1969
  • Correlation between the blood clearance half time and findings of liver scan using the colloidal radiogold in patients of liver cirrhosis is observed through the scoring system, in which the more changes in size, shape and density in the liver scan, the more points are given (table 1). Results: 1) Within the increase in severity of hepatocellular dysfunction in liver cirrhosis, the degree and frequency of following changes in liver scan (done with colloidal radiogold) were increased in order. a) generalized hepatomegaly b) enlargement of the left lobe & reduction of the right lobe c) relatively increased radiodensity in the left lobe and 4) visualization of spleen. 2) Frequency of the normal scan in liver cirrhosis was $12{\pm}3.56%$, frequency of normal value in blood clearance half time of the radiogold was $5.0{\pm}2.34%$ and frequency of normal scan & normal blood clearance rate in liver cirrhosis was $3.6{\pm}2.06%$.

  • PDF

A Study on the Chest Radiography for Reducing Exposure Dose (흉부X선촬영(胸部X線撮影)에 있어서 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Lee, Man-Koo;Yoon, Han-Sik;Lee, Jong-Seok;Lee, Sun-Sook;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.41-49
    • /
    • 1996
  • We have been used super sensitive screen/film system which is thought to be the limit of sensitivity, however, we think this method is not satisfactory. As a general radiographic rule, reduction of exposure is inconsistent with improvement of image quality, but it is necessary to challenge this rule to get better method. We tried air gap method for minimal diffuse lung shadow which is difficult to find out by our routine method. As a result, air gap method with super sensitive screen/film system(SRO 1000/TMH) showed lower exposure dose, 50% of our routine system(SRO 750/SRH with grid), and better image quality for pulmonary pattern in the lower lung field.

  • PDF

Combined Effects of Radiation and Ultrasound on Embryonic Development in Mice (ICR 마우스의 태아(胎兒)에 대(對)한 방사선(放射線)과 초음파(超音波)의 공동효과(共同效果)에 관한 실험적(實驗的) 검토(檢討))

  • Gu, Yeun-Hwa
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.37-44
    • /
    • 1991
  • The combined effect of radiation and ultrasound has been studied in mouse embryos. Radiation and/or ultrasound were adminstered to ICR mice on day 8 of gestation. Intrauterine death, gross malformation, and fetal body weight were selected as indicators of effects. Does of whole-body ${\gamma}-irradiation$ were 0.5 to 2.5 Gy and those of ultrasound were $0.5\;W/cm^2$ to $3\;W/cm^2$. Intrautrine mortality increased with increasing radiation dose ; this trend was more remarkable in combination with ultrasound. Gross malformations such as exencephaly and anophthalmia/microphthalmia appeared frequently in the fetuses treated with both radiation and ultrasound. Decreased fetal weight was observed even in mice treated with 1.5 Gy of radiation or $1\;W/cm^2$ of ultrasound. There was a linear relationship between dose and reduction of fetal weight. The fetal weight was sensitive, precise and easy-to-handle indicator for the effects of growth retardation. Intrauterine mortality and frequencies of exencephaly and anophthalmia/microphthalmia were higher than the sum of those induced by radiation and by ultrasound. The results indicatied that the combined action of radiation and ultrasound on intrauterine death and malformations was synergistic.

  • PDF

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

Analysis and radiation dose assessment of 222Rn in indoor air at schools: Case study at Ulju County, Korea

  • Lee, ChoongWie;Choi, Sungyeol;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.806-813
    • /
    • 2018
  • $^{222}Rn$ exists in nature in the form of a rare radioactive gas. In terms of environmental radiation, issues regarding $^{222}Rn$ have persisted because of its radiological hazardousness. Ulju County is one of the regions of Ulsan metropolitan city, with a population of 227,699. Ulju County has the highest density of industrial complexes in Korea. In this study, $^{222}Rn$ radioactivity concentration was measured and analyzed in 57 schools in Ulju County using 114 passive LR-115 type detectors to secure radiological safety and confirm basic information for reduction of resident exposure to $^{222}Rn$. The effective dose of $^{222}Rn$ was assessed to find the actual risk of the concentration surveyed in schools to human beings. The dose depended on four factors: subjects, $^{222}Rn$ concentration, dose coefficient, and time. The individuals subjected to dose estimation were classified into three types: students, teachers, and office workers. The subjects had different dwelling locations and times. The findings demonstrate that the radiological hazard to students and workers at schools in Ulju County owing to $^{222}Rn$ is negligible in terms of $^{222}Rn$ activity recommendation level.