• Title/Summary/Keyword: Radiological reduction

Search Result 447, Processing Time 0.024 seconds

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.

A Study about Reduction Method of the X-Ray Film Image (X선 사진의 감력법에 대한 실험 고찰)

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.55-55
    • /
    • 1991
  • I reduced overexposed X-Ray film image with farmer reduction method and $KMnO_4$ reduction method. The results are as follows : 1. In farmer reduction method, there appears linear decreasing film image density. 2. In $KMnO_4$ reduction method, there appears over proportional reduction. 3. When red prussiate is compared with $KMnO_4$ reduction method, the latter shows more intense reduction. 4. If the reduction solution isn't used within 10 minutes after dilution, it becomes oxidized and the ability is decreased remarkably.

  • PDF

A Study on Property of Microstructuree for Ba System of Perovskite Structure (페로브스카이형 Ba계열의 미세구조 특성)

  • Song, Min-Jong;Dong, Kyung-Rae;Kim, Chang-Bok;Choi, Seong-Kwan;Park, Yong-Soon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.185-189
    • /
    • 2011
  • To assess the prevalence of various radiological reduction methods for childhood intussusception in training hospitals by means of a nationwide phone survey, and to demonstrate recent trends in this area by comparing the findings with those obtained in a survey conducted. $BaTiO_3$ system was prepared by using fabrication of classical conditioning ceramics. Polycrystalline and surface structure characteristics of the specimens were measured by X-ray diffraction, SEM(Scanning Electron Microscopy) and EDAX (Energy Dispersive Spectrometer), respectively.

  • PDF

Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study (PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구)

  • Cho, Young Hyun;Lee, Se Jeong;Lee, Youngjin;Park, Chan Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

A Systematic Review of Trends for Image Quality Improvement in Light Microscopy (광학 현미경 영상 화질개선의 추세에 관한 체계적 고찰)

  • Kyuseok Kim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.207-217
    • /
    • 2023
  • Image noise reduction algorithm performs important functions in light microscopy. This study aims to systematically review the research trend of types and performance evaluation methods of noise reduction algorithm in light microscopic images. A systematic literature search of three databases of publications from January 1985 to May 2020 was conducted; of the 139 publications reviewed, 16 were included in this study. For each research result, the subjects were categorized into four major frameworks-1. noise reduction method, 2. imaging technique, 3. imaging type, and 4. evaluation method-and analyzed. Since 2003, related studies have been conducted and published, and the number of papers has increased over the years and begun to decrease since 2016. The most commonly used method of noise reduction algorithm for light microscopy images was wavelet-transform-based technology, which was mostly applied in basic systems. In addition, research on the real experimental image was performed more actively than on the simulation condition, with the main case being to use the comparison parameter as an evaluation method. This systematic review is expected to be extremely useful in the future method of numerically analyzing the noise reduction efficiency of light microscopy images.

Arsenite induces premature senescence via p53/p21 pathway as a result of DNA damage in human malignant glioblastoma cells

  • Ninomiya, Yasuharu;Cui, Xing;Yasuda, Takeshi;Wang, Bing;Yu, Dong;Sekine-Suzuki, Emiko;Nenoi, Mitsuru
    • BMB Reports
    • /
    • v.47 no.10
    • /
    • pp.575-580
    • /
    • 2014
  • In this study, we investigate whether arsenite-induced DNA damage leads to p53-dependent premature senescence using human glioblastoma cells with p53-wild type (U87MG-neo) and p53 deficient (U87MG-E6). A dose dependent relationship between arsenite and reduced cell growth is demonstrated, as well as induced ${\gamma}H2AX$ foci formation in both U87MG-neo and U87MG-E6 cells at low concentrations of arsenite. Senescence was induced by arsenite with senescence-associated ${\beta}$-galactosidase staining. Dimethyl- and trimethyl-lysine 9 of histone H3 (H3DMK9 and H3TMK9) foci formation was accompanied by p21 accumulation only in U87MG-neo but not in U87MG-E6 cells. This suggests that arsenite induces premature senescence as a result of DNA damage with heterochromatin forming through a p53/p21 dependent pathway. p21 and p53 siRNA consistently decreased H3TMK9 foci formation in U87M G-neo but not in U87MG-E6 cells after arsenite treatment. Taken together, arsenite reduces cell growth independently of p53 and induces premature senescence via p53/p21-dependent pathway following DNA damage.

Evaluation of Metal Artifact Reduction for Orthopedic Implants (O-MAR) on Radiotherapy Treatment Planning (방사선 치료 계획 시 O-MAR (Metal Artifact Reduction for Orthopedic Implants) 적용의 유용성 평가)

  • Won, Huisu;Hong, Joowan;Kim, Sunyoung;Choi, Jaehyock;Cho, Jaehwan;Yang, Hanjoon;Lee, Jin;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.217-223
    • /
    • 2014
  • The aim of this study is evaluation of dose distribution on radiation therapy planning system with the CT image of high-density material inserted phantom. Gammex 467 Tissue Characterization Phantom is used to acquire an image similar to the human tissues and insert a Titanium to generate metal artifact. The acquired images were reconstructed with Metal Artifact Reduction for Orthopedic Implants (O-MAR). By using the treatment planning system, the volume was analyzed and dose distribution was extracted. Photon dose distribution in linear accelerator was measured by the $MapCHECK^{TM}$ and compared with planned and measured dose distributions. In result of the comparative analysis, when artifact is generated by Titanium, The volume applied O-MAR was increased 6.8% to BR-12 Breast and 40.2% to LV 1 Liver. After O-MAR was used, Dose distribution was higher 1.4 to 1.6% than before. Consequently, The artifact caused by metal objects should be removed if possible, and after that used in the radiotherapy treatment plan can be considered to reduce errors.

Feasibility Study of Improved Patch Group Prior Based Denoising (PGPD) Technique with Medical Ultrasound Imaging System

  • Kim, Seung Hun;Seo, Kanghyen;Kang, Seong Hyeon;Kim, Jong Hun;Choi, Won Ho;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.55-59
    • /
    • 2017
  • The purpose of this study was to quantitatively evaluate image quality using intensity profile, coefficient of variation (COV), and peak signal to noise ratio (PSNR) with respect to noise reduction techniques in the ultrasound images. For that purpose, we compared with the median filter, Rudin-Osher-Fatemi (ROF), Anscombe and proposed patch group prior based denoising (PGPD) techniques. To evaluate image quality, the Shepp-Logan phantom and the ultrasound image were acquired using simulation and experiment, respectively. According to the results, the difference of intensity profile using PGPD technique is lowest compared with original Shepp-Logan phantom. In simulation, the measured COV was 0.249, 0.198, 0.198, 0.177, and 0.080 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Also, in experimental image, the measured COV was 0.245, 0.230, 0.231, 0.242 and 0.187 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Especially, when we used PGPD technique, the PSNR has highest value in both simulation and experiment. In this study, we performed simulation and experiment study to compare various denoising techniques in the ultrasound image. We can expect the PGPD technique to improve in medical diagnosis with excellent noise reduction.