• Title/Summary/Keyword: Radiological characteristics

검색결과 658건 처리시간 0.03초

Gamma Knife Surgery for Brain Metastasis from Renal Cell Carcinoma : Relationship Between Radiological Characteristics and Initial Tumor Response

  • Kim, Jin-Wook;Han, Jung-Ho;Park, Chul-Kee;Chung, Hyun-Tai;Paek, Sun-Ha;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권2호
    • /
    • pp.92-96
    • /
    • 2007
  • Objective : The authors have speculated that metastatic brain lesions from renal cell carcinoma (RCC) show diverse radiological patterns and tumor responses after Gamma knife surgery (GKS), and have hypothesized that these can be predicted from tumor radiological characteristics. The goal of the current study was to identify the radiological characteristics of RCC brain metastases and the predictors of initial radiosurgical response after GKS. Methods : A retrospective analysis was performed on 48 lesions in 18 patients with RCC brain metastasis treated by GKS. The radiological characteristics of these lesions in magnetic resonance images (MRI) were classified into 3 categories according to enhancement patterns in T1-weighted images and signal intensity characteristics in T2-weighted images. Responses to GKS were analyzed according to these categories, and in addition, other potential predictive factors were also evaluated. Results : MRI findings in the three categories were diverse, though numbers of the lesion were comparable. At 2-month MRI follow-ups after GKS, response rate was 54% and the local tumor control rate 83%. T2 signal intensity was found to be the principal predictive factor of response to GKS, namely negative predictive factor. Other variables such as age, sex, tumor volume, dose, duration from initial diagnosis to GKS, and previous systemic therapies failed to show significant relationships with treatment response by multivariate analysis. Conclusion : Careful evaluation of the radiological characteristics of brain metastases from RCC is important prior to GKS because MRI heterogeneity has predictive value in terms of determining initial tumor response.

광학 전산화단층촬영 스캐너 사용을 위한 중합체 겔과 BANGTM 겔 선량계의 특성 비교 (Comparison of Polymer and BANGTM Gel Dosimeters to Use a Optical Computed Tomography Scanner)

  • 장경환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.107-114
    • /
    • 2023
  • The purpose of this study was to compare the basic radiological characteristics of in-house polymer gel and commercially-available gel (BANGTM) gel dosimeters with a spectro-photometer to use a optical computed tomography (CT) scanner. We investigated the radiological characteristics including dose linearity, absorbance spectrum, dose rate dependency and inter-and intra-reproducibility at wavelengths of 590, 600 and 630 nm. The optimal dose linearities of two gel dosimeters showed R2 value of 0.939 and 0.948 at wavelengths of 590 nm and 600 nm, respectively. For two polymer gel dosimeters, there is no peak sensitivity within the range of all wavelengths in absorbance spectrum. For in-house gel dosimeter, the dose rate dependency were within 5% for all wavelengths except for the dose rate of 100 MU/min. For BANGTM gel dosimeter, the dose rate dependency showed an error range of ±5% for all wavelengths. The inter-and intra-reproducibility of two gel dosimeters were within the range of 2.5%. We have confirmed that the two gel dosimeters was appropriate for use with a optical CT scanner.

초음파사와 방사선사의 인구학적 및 직무 특성과 직무 만족도의 비교분석 (Comparison of Demographic and Job Characteristics with Job Satisfaction between Sonographers and Radiological Technologists)

  • 김혜진;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.389-397
    • /
    • 2021
  • The purpose of this study was to compare the demographic and job characteristics and job satisfaction of sonographers (SONO) and radiological technologists (RT). The subjects were a total of 148 people (69 SONO, 79 RT), who had been working in clinical and hospitals. The method was conducted using a questionnaire with a total of 54 questions consisting of demographic characteristics, job characteristics, and job satisfaction. Reliability was secured with Cronbach's alpha coefficient of 0.6 or higher for the response of the questionnaire. For statistical analysis, descriptive statistics, cross-analysis, independent sample T-test, and correlation analysis using Pearson's correlation coefficient and Spearman's correlation coefficient were performed for each occupation. As a result, first, the SONO had more female workers than RT. They are more than three times as many in graduate school and above. Second, the SONO had 4.5 times more morning shift than the RT and no form of weekend shift. Third, the average monthly salary of the SONO is higher than that of the RT, but when a certain portion of the salary goes up, the salary no longer goes up. Fourth, satisfaction with expectations, growth desire, positive mentality, growth opportunity, job importance, organizational attachment was higher SONO than the RT, but self-efficacy was higher in RT than SONO. Last, SONO had higher educational background than RT. It is hoped that the results of this study will be able to understand the job characteristics of SONO and RT and identify the factors of job satisfaction and provide them as fundamental materials for job selection.

방사선검사의 의무기록에 관한 요구도 분석 (Analysis of the Necessity of Medical Records Related to Radiological Examination)

  • 홍동희;임청환;임우택;주영철;정홍량;김은혜;윤용수;정영진;최지원;정성훈;박명환;양오남;정봉재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.

3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가 (Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

영남지역 방사선사의 초음파검사 직무특성 분석 (Analysis of Job Characteristics for Ultrasound Examination of Radiological Technologists in Yeongnam Area)

  • 정봉재;이상훈
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.639-647
    • /
    • 2022
  • 본 연구는 영남지역에서 초음파검사를 담당하고 있는 방사선사를 대상으로 직무특성을 분석하였다. 연구에 사용한 측정도구는 설문지로 2021년 08월01일부터 11월30일까지 영남지역에 소재하는 의료기관에서 초음파검사를 담당하는 방사선사를 대상으로 하였다. 코로나19 상황을 감안하여 비대면 방식으로 e-mail, SNS 등을 이용하여 연구에 적합한 158부를 SPSS/PC Ver 18.0 프로그램을 이용하여 분석하였다. 연구대상자의 일반적 특성과 초음파검사자의 직무특성을 기술통계, 신뢰도분석, t-test, 분산분석, 상관관계, 회귀분석으로 실시하였다. 영남지역에서 초음파검사를 담당하는 방사선사의 직무특성을 전체 직무만족수준으로 분석한 결과 직무만족수준은 3.24 ± 0.61로 나타났다. 평균 3.0점 보다 높은 수준으로, 직무특성요인이 직무만족에 미치는 영향에서는 전문적 지위, 자존감, 신뢰관계 형성이 높게 나타났다. 그러나 보상과 업무의 적절성에서는 불만족하는 요인으로 파악되었다. 그러므로 영남지역에서 초음파검사를 담당하는 방사선사의 직무특성과 만족수준을 향상시키기 위해서는 의료기관의 적절한 업무환경개선과 초음파검사를 담당하는 방사선사의 지속적인 전문성확보를 위한 노력에 최선을 다하여야 할 것이다.

3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구 (Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;한지현;이시내;한송이;김기원;김현수;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

페로브스카이형 Ba계열의 미세구조 특성 (A Study on Property of Microstructuree for Ba System of Perovskite Structure)

  • 송민종;동경래;김창복;최성관;박용순
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.185-189
    • /
    • 2011
  • To assess the prevalence of various radiological reduction methods for childhood intussusception in training hospitals by means of a nationwide phone survey, and to demonstrate recent trends in this area by comparing the findings with those obtained in a survey conducted. $BaTiO_3$ system was prepared by using fabrication of classical conditioning ceramics. Polycrystalline and surface structure characteristics of the specimens were measured by X-ray diffraction, SEM(Scanning Electron Microscopy) and EDAX (Energy Dispersive Spectrometer), respectively.

  • PDF