• 제목/요약/키워드: Radiological Safety

검색결과 542건 처리시간 0.037초

What are Technical Hurdles of Verification for North Korea's Nuclear Program?

  • Choi, Sungyeol;Jun, Eunju
    • 방사성폐기물학회지
    • /
    • 제20권1호
    • /
    • pp.111-118
    • /
    • 2022
  • The denuclearization of North Korea was unpredictable and resulted in radical changes. Despite the skepticism and disappointment surrounding denuclearization, it is important for certain verification technologies to establish what is technically possible or practically impossible, and how reliable these technical means are. This article presents the technical hurdles in nuclear verification by systematically categorizing them into issues of correctness and completeness. Moreover, it addresses the safety and security risks during the denuclearization process, including the radiological impact on humans, environmental effects, and the illegal transfer of material, information, and technologies.

치과 파노라마 촬영에서 공간선량률 분석 (Analysis of the Spatial Dose Rates during Dental Panoramic Radiography)

  • 고종경;박명환;김용민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.509-516
    • /
    • 2016
  • 저선량 장시간(15초 내외) X선을 조사하는 치과 파노라마 촬영장치는 교육 목적의 사용에는 원자력안전법의 규제를 받으며, 이에 따라 방사선안전 설비(경보장치, 인터록)를 설치해야 한다. 본 연구에서는 치과 파노라마 촬영에서 방사선량 및 공간선량률을 측정하여 방사선안전 설비의 실효성을 확인하고 방사선작업종사자 및 수시출입자 등의 방사선방호를 위한 기초자료를 제공하고자 하였다. 치과 파노라마 전용팬텀의 직접 피폭부위인 치아와 간접 피폭부위인 수정체와 갑상선에서 유리선량계 소자(GD-352M)를 부착한 후 X선을 3회 반복 조사하여 형광유리선량계 시스템으로 선량을 판독하였다. 팬텀 절치부를 중심으로 한 수평면을 $45^{\circ}$ 각도로 분류하여 7방향으로 구획하여 각 방향마다 30, 60, 90, 120 cm의 거리에서 공간선량률을 측정하였다. 직접 피폭부위는 최대 $984.5{\mu}Gy$가 측정되었다. 공간선량률은 30 cm에서 가장 높게 나타났으며, 120 cm로 거리가 증가할수록 선량이 감소하였다. 방향에 따라서는 30 cm 거리에서 회전 시작부위의 공간선량률이 $3,840{\mu}Sv/h$로 가장 낮은 부위인 $778{\mu}Sv/h$에 비해 4배 차이가 났다. 방사선작업종사자가 위치할 수 있는 60 cm 거리에서의 공간선량률은 평균 $408{\mu}Sv/h$로 측정되었다. 보수적인 관점에서 방사선관리구역 내에 의도하지 않은 피폭이 발생하는 경우를 대비하여 피폭선량 예측이 가능하도록 공간선량률에 대한 방사선안전 교육이 필요하지만, 현재 의료법에 의해 의료기관에서는 설치하지 않아도 되는 인터록 등의 설비는 교육용 치과 파노라마 촬영실의 공간선량률이 낮은 것을 감안할 때 원자력안전법에서 의무화 되어 있는 것은 과한 규제로 사료된다.

저강도 초음파 치료기기의 안전성 및 성능평가 가이드라인 수립을 위한 연구 (A Study on the Safety and Performance Test Guideline of Low Intensity Therapeutic Ultrasound Device)

  • 김주영;김재영;노시철;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.162-168
    • /
    • 2015
  • In this study, we suggested the performance and safety testing guideline for low intensity pulsed ultrasound (LIPUS) represented by the ultrasound fracture treatment device and cartilage treatment device and low intensity focused ultrasound (LIFU) represented by ultrasonic face lifting device. For these study, the international standards and management regulations of Korea, Japan and United State were analyzed. And the usefulness and applicability were evaluated by testing with commercial equipment and reflecting the views of the industry and experts. As a result of this study, the safety and performance test guidelines for low intensity therapeutic ultrasound device were proposed by presenting the 10 items for LIPUS and 12 items for LIFU. The suggested guidelines are considered a high utilization in the domestic testing and approval authorities. And they are also thought to be useful to new technology development.

Radiographic Features of Traumatically Caused Retroflexion of Urinary Bladder in Two Dogs

  • Lee, Hae-Beom;Kang, Hye-Won;Kim, Min-Su;Kim, Nam-Soo;Lee, Ki-Chang
    • 한국임상수의학회지
    • /
    • 제25권6호
    • /
    • pp.553-556
    • /
    • 2008
  • The urinary bladder retroflexion, flipped over backwards into the pelvic canal, by trauma has been rarely reported in dogs. This paper describes clinical and radiological features of urinary bladder retroflexion in two dogs with a history of traffic accident. The main clinical signs were hind limb lameness, severe pain and dysuria. Radiography and ultrasonography were performed to evaluate the patient's damages. No remarkable findings were observed except pelvic fracture on survey radiograph. On cystourethrography, caudal displacement and retroflexion of the bladders were identified. Cystopexy was performed and the bladders were repositioned. After surgery one dog with severe azotemia and bilateral hydroureteronephrosis was deteriorated noticeably and euthanized by request of the owner, while the other dog was recovered no recurrence of the problem by 12 months post-surgery. It should be considered that contrast study and serial assessment in urinary tract be important to demonstrate the evidence of bladder retroflexion and evaluate the prognosis in dogs with severe trauma.

A Study About Radionuclides Migration Behavior in Terms of Solubility at Gyeongju Low- and Intermediate-Level Radioactive Waste (LILW) Repository

  • Park, Sang June;Byon, Jihyang;Lee, Jun-Yeop;Ahn, Seokyoung
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.113-121
    • /
    • 2021
  • A safety assessment of radioactive waste repositories is a mandatory requirement process because there are possible radiological hazards owing to radionuclide migration from radioactive waste to the biosphere. For a reliable safety assessment, it is important to establish a parameter database that reflects the site-specific characteristics of the disposal facility and repository site. From this perspective, solubility, a major geochemical parameter, has been chosen as an important parameter for modeling the migration behavior of radionuclides. The solubilities were derived for Am, Ni, Tc, and U, which were major radionuclides in this study, and on-site groundwater data reflecting the operational conditions of the Gyeongju low and intermediate level radioactive waste (LILW) repository were applied to reflect the site-specific characteristics. The radiation dose was derived by applying the solubility and radionuclide inventory data to the RESRAD-OFFSITE code, and sensitivity analysis of the dose according to the solubility variation was performed. As a result, owing to the low amount of radionuclide inventory, the dose variation was insignificant. The derived solubility can be used as the main input data for the safety assessment of the Gyeongju LILW repository in the future.

방사성폐기물 처분시설에서 생태계 모델의 입력데이터 선정에 대한 고찰 (Considerations on Screening for the Input Data of the Biosphere Model in the Radioactive Waste Disposal Facility)

  • 정미선;박동국;김수진;정강일
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.209-217
    • /
    • 2023
  • The biosphere has important function in the safety assessment of a radioactive waste disposal facility. A biosphere model in the safety assessment needs various input data that contain significantly inherent uncertainties. This paper reviews the effects of the input data on the radiological impact assessment from main radionuclides such as 14C and 99Tc in the biosphere model. In addition, it is confirmed that the safety criteria is met, when the conservative input data for the intake rate, soil to plant concentration ratio, and distribution coefficients of the radionuclides are applied and probabilistic analysis are conducted in the biosphere model. Nevertheless, it is required to generate site-specific input data for the confidence building and reduce excessive conservatism in the biosphere model.

국내 사이클로트론 이전 및 해외 해체 사례 분석을 통한 해체 계획 기준 도입 연구 (A Study on the Adoption of Cyclotron Decommissioning Plan Criteria by the Analysis of Domestic Relocation and Abroad Dismantling Practices)

  • 우리나;김용민;송민철;조대형;이재성;김완태
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.91-99
    • /
    • 2013
  • 사이클로트론은 그 자체의 수명에 의한 마모 파손뿐만 아니라 사용목적의 변경, 장소 이전, 업그레이드 등의 다양한 이유로 해체 또는 폐기를 경험하게 된다. 실제 미국과 유럽에서도 후자의 이유로 해체된 사례가 많고 또한 많은 양의 저준위 방사성 폐기물을 발생시켰으며 이에 따른 큰 해체 비용을 야기하였다. 유럽과 미국에서는 미래 해체 비용 감소 를 위해 많은 연구를 수행하였으며 미국에서는 허가시 해체 자금 계획(DFP, Decommissioning Funding Plan)을 제출 하도록 하고 있다. 사이클로트론 해체를 위해서는 기술적 측면(해체 절차, 제염 기술 등)과 안전성 측면(잔류 방사능, 예상선량 등)에서 해체 작업의 성취 정도를 예측함으로 해체 비용의 감소 및 방사성 폐기물관련 문제를 해결할 필요가 있다. 본 연구에서는 ANL (Argonne National Laboratory)과 벨기에(유럽위원회 주관)에서 수행된 사이클로트론 해체 사례를 분석하고 2012년 12월 수행된 국내 서울대학교병원 사이클로트론 해체 이전 사례를 살펴봄으로써 향후 사이클 로트론 해체 기준 수립을 위한 기초 자료를 제공하고자 하였다. 이를 위하여 IAEA (International Atomic Energy Agency)와 NRC (Nuclear Regulatory Commission)의 사이클로트론 해체 관련 기준을 분석하고 향후 방사성 폐기물 규제해제(이하 자체처분) 및 재사용과 해체 자금 계획(DFP)의 국내 도입 방안을 제시하였다. 도출된 자료는 사이클로 트론 해체시 방사화되는 정도를 예측하고 국내에 적용할 수 있는 효율적인 해체 요건과 기준들을 정립하는데 활용될 수 있을 것으로 판단된다.

촬영 및 투시용 X선 장치의 기본안전과 필수 성능에 관한 개별 기준규격의 동향 (The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy)

  • 노영훈;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.331-336
    • /
    • 2015
  • 식품의약품안전처 고시 "의료기기의 전기 기계적 안전에 관한 공통기준규격"이 IEC 60601-1 [3판] 따라 개정되었고 IEC-60601-1의 개별규격인 IEC 60601-2-54 또한 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 개별 기준규격으로 고시화 될 예정이다. 따라서 개별 규격의 도입에 앞서 주요 요건을 소개하고자 이 기술보고서를 작성하였다. IEC 60601-2-54의 목적은 촬영 및 투시를 위한 의료용 전기기기(이하 ME 기기) 및 ME 시스템에 요구되는 기본 안전과 필수 성능 요구사항을 확보하려는 것이다. IEC 60601-2-54는 방사선 촬영 및 투시장치의 X선 고전압장치, X선 기계장치, 방사선 방어 등에 관한 내용이다. 의료기기의 전기 기계적 안전에 관한 공통기준규격, 의료기기의 전자파 안전에 관한 공통기준규격, 의료기기의 방사선안전에 관한 보조기준 규격이 본 규격에 적용되었다. IEC-60601-2-54가 고시화될 경우 촬영 및 투시용 X선 장치의 기본 안전과 필수 성능에 관한 이해를 넓히고 국내 의료기기 산업의 국제화에 일조할 것이라고 판단된다.

방사선작업종사자 및 방사선관계종사자의 현황 분석과 교내 실습 만족도 조사를 통한 방사선(학)과의 규제에 대한 고찰 (A Study on Regulations Through Analysis of the Status of Radiation Workers and Related Workers and Satisfaction Survey in the Radiology Department)

  • 정현서;이용기;안성민
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.327-334
    • /
    • 2022
  • 본 연구에서는 방사선(학)과 재학 중 교내 실습의 만족도에 대한 설문과 방사선관계종사자 및 방사선작업종사자의 현황 등을 조사해 방사선(학)과에 대한 원자력안전법의 규제에 대한 실효성 및 타당성에 대한 기초 연구에 목적을 두었다. 방사선(학)과 재학 중 수시출입자로 지정되어 교내 실습 중 방사선 발생장치를 취급 및 조작하지 못한 종사자의 실습 만족도는 만족하지 못한다가 34.62%로 나타났다. 반면 재학 중 방사선작업종사자로 지정되거나 원자력안전법의 규제 이전에 재학하여 방사선 발생장치를 취급 및 조작한 종사자의 실습 만족도는 만족한다가 50%로 나타났다. 또한 교육기관의 방사선작업종사자의 연간 피폭선량은 0.05 mSv 이하로 나타났다. 방사선작업종사자와 방사선관계종사자의 추이를 보면 방사선(학)과를 졸업한 학생들은 의료기관 중에서도 방사선관계종사자로 등록된 진단용 방사선 발생장치를 취급하는 분야로 가장 많은 취업을 한다는 것을 알 수 있다. 따라서 현재의 원자력안전법의 규제를 완화하거나 의료법 및 진단용 방사선 발생장치의 안전관리에 관한 규칙 등을 개정하여 의료기사 등에 관한 법률에서 정한 방사선(학)과 학생들의 학습권을 보장하고 실무 중심의 교육이 이루어질 수 있도록 하는 것이 필요하다고 사료된다.