• Title/Summary/Keyword: Radiological Safety

Search Result 538, Processing Time 0.024 seconds

Method for clearance of contaminated buildings in Korea research reactor 1 and 2

  • Geun-Ho Kim ;Dooseong Hwang;Jung Ho Song;Junhyuck Im;Junhee Lee ;Minyoung Kang ;Kwang Pyo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1959-1965
    • /
    • 2023
  • The objective of this study was the establishment of clearance method that can ensure radiological safety and reasonably minimize radioactive waste when demolishing contaminated buildings at KRR-1&2. By reviewing Korean and international laws related to decommissioning, the method for clearance of contaminated buildings presented in this study is to first decontaminate the building and then conduct a radiological safety assessment, such as measuring residual radioactivity, to determine whether the radiation dose criteria for clearance are satisfied. The measurement results meet the radiation dose criteria, the contaminated buildings are regarded as clearance and can be converted into the general buildings. The demolition of the cleared buildings is carried out using conventional demolition methods. The waste generated during the demolition is classified as general construction waste and is disposed of according to relevant laws. The proposed method significantly optimized the number of samples analyzed and reduced the time and cost associated with the decommissioning. The established method will be applied to the ongoing decommissioning of contaminated buildings at KRR-1&2, and its application will be verified by regulatory bodies. The study suggests that this method could be used for the decommissioning of contaminated buildings at other Korean nuclear facilities in the future.

A Study on Economic Methodology for Deriving Money Coefficients (금전계수 도출을 위한 경제학적 방법론 연구)

  • Min-Hee Back
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.111-118
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) 103 recommends a cost-benefit analysis method as an auxiliary tool for scientific and rational decision-making for the principle of optimization of radiological protection. In order to conduct a cost-benefit analysis, the safety improvement of nuclear power by regulation must be measured and converted into monetary terms. The improvement of nuclear safety can be measured by reducing the radiation exposure dose of the people, and it is necessary to determine the coefficient to convert the radiation exposure dose into money. The monetary coefficient is calculated as the product of the statistical life value (VSL) and the nominal risk coefficient. In order to derive the monetary coefficient, the willingness to pay (WTP) can be estimated using the contingent valuation method (CVM), which quantifies the value of non-market goods by converting them into monetary units. WTP can be estimated based on the random utility model, which is the basic model for bivariate selection type conditional value measurement data. Statistical life value can be calculated using the estimated WTP and reduction in early mortality, and a monetary coefficient can be derived.

Report for Spreading Culture of Medical Radiation Safety in Korea : Mainly the Activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) (국내 의료 방사선 안전문화 활동 현황 : 의료방사선안전문화연합회 중심으로)

  • Yoon, Yong-Su;Kim, Jung-Min;Kim, Hyun-Ji;Choi, In-Seok;Sung, Dong-Wook;Do, Kyung-Hyun;Jung, Seung-Eun;Kim, Hyung-Soo
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • There are many concerns about radiation exposure in Korea after Fukushima Nuclear Plant Accident on 2011 in Japan. As some isotope materials are detected in Korea, people get worried about the radioactive material. In addition, the mass media create an air of anxiety that jump on the people's fear instead of scientific approach. Therefore, for curbing this flow, health, medical institute from the world provide a variety of information about medical radiation safety and hold the campaign which can give people the image that medical radiation is safe. At this, the Korean Food and Drug Administration(KFDA) suggested that make the alliance of medical radiation safety and culture on August, 2011. Seven societies and institutions related medical radiation started to research and advertise the culture of medical radiation safety in Korea. In this report, mainly introduce the activities of the Korean Alliance for Radiation Safety and Culture in Medicine(KARSM) for spreading culture of medical radiation safety from 2011 to 2012.

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.

Thoracic Duct Embolization for Treatment of Chyle Leakage After Thyroidectomy and Neck Dissection

  • Sungmo Moon;Juil Park;Gyoung Min Kim;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Hyung Cheol Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.55-61
    • /
    • 2024
  • Objective: This study aimed to evaluate the safety and efficacy of intranodal lymphangiography and thoracic duct embolization (TDE) for chyle leakage (CL) after thyroid surgery. Materials and Methods: Fourteen patients who underwent intranodal lymphangiography and TDE for CL after thyroid surgery were included in this retrospective study. Among the 14 patients, 13 underwent bilateral total thyroidectomy with neck dissection (central compartment neck dissection [CCND], n = 13; left modified radical neck dissection (MRND), n = 11; bilateral MRND, n = 2), and one patient underwent left hemithyroidectomy with CCND. Ten patients (76.9%) had high-output CL (> 500 mL/d). Before the procedure, surgical intervention was attempted in three patients (thoracic duct ligation, n = 1; lymphatic leakage site ligation, n = 2). Lymphangiographic findings, technical and clinical successes, and complications were analyzed. Technical success was defined as the successful embolization of the thoracic duct after access to the lymphatic duct via the transabdominal route. Clinical success was defined as the resolution of CL or surgical drain removal. Results: On lymphangiography, ethiodized oil leakage near the surgical bed was identified in 12 of 14 patients (85.7%). The technical success rate of TDE was 78.6% (11/14). Transabdominal antegrade access was not feasible due to the inability to visualize the identifiable cisterna chyli or a prominent lumbar lymphatic duct. Among patients who underwent a technically successful TDE, the clinical success rate was 90.1% (10/11). The median time from the procedure to drain removal was 3 days (with a range of 1-13 days) for the 13 patients who underwent surgical drainage. No CL recurrence was observed during the follow-up period (ranging from 2-44 months; median, 8 months). There were no complications, except for one case of chylothorax that developed after TDE. Conclusion: TDE appears to be a safe and effective minimally invasive treatment option for CL after thyroid surgery, with acceptable technical and clinical success rates.

Factors affecting radiation safety management practice of radiation workers in dental medical institutions (치과의료기관 방사선관계종사자의 방사선 안전관리 실천도에 영향을 미치는 요인)

  • Lee, Eun-Gyeong;Jang, Gye-Won;Kweon, Dae-Cheol;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.251-263
    • /
    • 2019
  • Objectives: To establish foundations for reinforcing radiation safety management in dental facilities. Methods: This study investigated the status of radiation safety management among radiation workers in dental facilities nationwide for a period of six months from July to December in 2018 and analyzed the factors that affect their compliance with radiation safety measures. Results: Compliance with safety measures was higher in the Honam region (p<0.01) and Yeongnam region (p<0.01), in university hospitals and general hospitals (p<0.05), along with an increasing perception of the importance of safety management (p<0.001). Conclusions: It is important to strengthen education about radiation safety management, develop a radiation safety guideline that could be reasonably applied to dental institutions, and implement relevant regulations or legal grounds to promote compliance with these measures.

TECHNICAL EVALUATION OF THE CONTINUED OPERATION OF NPP

  • Kim, Tae-Ryong;Jin, Tae-Eun
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.277-284
    • /
    • 2008
  • Recently, the long-term operation of a nuclear power plant beyond its licensed term has become a worldwide trend as long as the safety of the plant is maintained in the extended period. Kori Unit 1, the oldest PWR in Korea, is the foremost example of this type of long-term operation in Korea. Comprehensive technical evaluation of the long-term operation of this plant was completed to confirm the overall safety of the plant. The technical evaluation included a review of PSR results, an assessment on aging management programs and time limited aging analyses, and a statement of radiological impact on the environment. Based on all of the results of the technical evaluation activities, Kori Unit 1 was approved to operate for an additional 10 years beyond its original design life of 30 years.

VALIDATION OF NUMERICAL METHODS TO CALCULATE BYPASS FLOW IN A PRISMATIC GAS-COOLED REACTOR CORE

  • Tak, Nam-Il;Kim, Min-Hwan;Lim, Hong-Sik;Noh, Jae Man;Drzewiecki, Timothy J.;Seker, Volkan;Downar, Thomas J.;Kelly, Joseph
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.745-752
    • /
    • 2013
  • For thermo-fluid and safety analyses of a High Temperature Gas-cooled Reactor (HTGR), intensive efforts are in progress in the developments of the GAMMA+ code of Korea Atomic Energy Research Institute (KAERI) and the AGREE code of the University of Michigan (U of M). One of the important requirements for GAMMA+ and AGREE is an accurate modeling capability of a bypass flow in a prismatic core. Recently, a series of air experiments were performed at Seoul National University (SNU) in order to understand bypass flow behavior and generate an experimental database for the validation of computer codes. The main objective of the present work is to validate the GAMMA+ and AGREE codes using the experimental data published by SNU. The numerical results of the two codes were compared with the measured data. A good agreement was found between the calculations and the measurement. It was concluded that GAMMA+ and AGREE can reliably simulate the bypass flow behavior in a prismatic core.

A Mathematical Model to Evaluate the Radiological Risks for the Reuse of Decommissioning Site (원자력시설 해체부지의 재이용을 위한 방사선학적 리스크 평가모델)

  • Cheong, Jae-Hak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.353-363
    • /
    • 2006
  • In order to evaluate the potential radiological risks for the reuse of the site after decommissioning of nuclear facilities, a mathematical model was developed and materialized into the Microsoft $Excel{\circledR}$ spreadsheets frame. A set of input parameter values was proposed, which is useful in the preliminary risk screening step before the detailed evaluation with the site-specific data. It appeared that the screening levels calculated by the present model was agreed with the derived concentration guideline limits resulted from RESRAD Ver.6.2 and the German dose criteria for releasing a nuclear site from regulatory control.

  • PDF