• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.03 seconds

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Analysis of Twinkling Artifacts Caused by Kidney Stones on Abdominal Ultrasound (복부 초음파 검사에서 신장결석으로 인해 발생되는 Twinkling 인공물에 관한 분석)

  • Kim, Ju-Hee;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.637-642
    • /
    • 2021
  • Kidney stones are largely classified into kidney stones, ureter stones, and urolithiasis depending on the location of their occurrence. Therefore, in this study, from January 2019 to June 2021, kidney stones found in 112 patients with flank pain or who visited for abdominal ultrasonography at a general hospital located in Daegu were diagnosed with urolithiasis. We wanted to investigate the effect on twinkling artifacts. As a result of the study, the incidence of twinkling artifacts due to kidney stones was relatively high in the longitudinal scan among the scan methods. As the number of kidney stones increased, the incidence of twinkling artifacts increased by 1.296 times (p<0.05). As the kidney stone size increased, the incidence of twinkling artifacts increased by 0.086-fold (p<0.05). It was found that the number and size of kidney stones are factors affecting twinkling artifacts. Since the effect of kidney stones on twinkling artifacts is related to the number and size of kidney stones, continuous attention should be paid to helping the detection of kidney stones by using variables affecting twinkling artifacts.

Analysis of Liver Elasticity according to Ultrasound Findings (초음파 소견에 따른 간 탄성도 분석)

  • Chun, Hye-Ri;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • This study was conducted on 101 patients who visited hospital for abdominal ultrasonography from May 2020 to December 2020. The purpose of this study was to find out the elasticity according to the ultrasound images (echo pattern, splenomegaly, hepatitis) during the ultrasound examination using the shear wave elastography. The shear wave elastography value of the normal group of the echo pattern was 5.75±1.58 kPa, and the group with the abnormal echo pattern was 8.84±4.94 kPa, and the shear wave elastography value of the abnormal group was high (p<0.05). In normal spleen size, hepatic elasticity value was 6.33±2.54 kPa, and hepatic elasticity value of splenomegaly was 13.73±5.48 kPa. In the case of splenomegaly, the liver elasticity value was high, and there was a statistically significant difference (p<0.05). As the spleen size increased, the liver elasticity value increased by 1.485 times, and as hepatitis progressed, the liver elasticity value increased by 1.573 times (p<0.05). As a result of analysis of concordance between ultrasound imaging findings and shear wave elastography, the Kappa value was found to be as high as 0.922 (p<0.05), which showed high concordance between the two test methods. Additional comparisons of liver elasticity values in shearwave elastography tests along with liver ultrasound findings are thought to be of great help in diagnosing liver fibrosis.

A Study on the Distribution of Microorganisms in Department of Radiography (영상의학과 촬영실의 미생물 분포에 관한 연구)

  • Chang, Jeong-Hyun;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.165-171
    • /
    • 2021
  • To prevent the secondary hospital-acquired infection (cross-infection) from occurring in the general radiographic room in the department of radiology, the microbial measurement was conducted at the points making direct close contact with radiologists and patients. For the case of radiologists, the microbial measurement and incubation were focused on the x-ray tube handle of the radiation generating device, and, for the case of patients, the microbial measurement and incubation were focused on the chin supporting device, chest-contact point, and handle. Once disinfected with Aniosurf, the sterilized media were gathered and identified, and the microorganisms were confirmed. Based on the identification results, it was confirmed that the points making direct close contact with radiologists showed a value of 103 CFU for Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp. and Candida spp., and that the points making direct close contact with patients showed a value of 103~5 CFU for Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM(Non-Tuberculosis Mycobacteria) and Candida spp.. It was also confirmed that the types and number of microorganisms gathered from the points making direct close contact with patients were greater. Fortunately, most of the involved microorganisms were observed to be on the skin surface and are known to become extinct when disinfected in accordance with the hospital-acquired infection control rules. However, since even minor exposure to such microorganisms may be lethal for patients with reduced immunity, caution must be taken. In particular, since the points making contact with patients showed a high level of microbial measurement, it was thought that it would be necessary for radiologists and personnel having frequent access to strictly disinfect the parts, such as instruments and handles, making frequent contact with patients. The purpose of this study was to announce the importance of safe microbial control in the radiographic inspection room in hospital, and this study is expected to be used as the baseline data for preventing hospital-acquired secondary infection and Nth infectious diseases.

Study on validity of the National Examination based on smart device based test(SBT) by 7 types of healthcare occupation (보건의료직종별 SBT 국가시험체제에 대한 타당성 연구)

  • Yoou, Soon-Kyu;Won, Jong-Soon;Lee, Koon-Ja;Han, Dong-Kyoon;Sung, Ho-Joong;Lee, Han-Suk;Chung, Lim-Hee;Kim, Eun-Joo;Choi, Hea-Kyung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.3
    • /
    • pp.7-34
    • /
    • 2018
  • Purpose: The purposes of this research were to study the validity of the National Examination based on smart based test(SBT) by 7 types of healthcare occupation. Methods: We conducted a questionnaires survey among 1,219 people including 210 professors for all 7 types of healthcare occupation and 573 clinical specialists ; 436 students from random sampling participated and the reliability of the questionnaire was tested using Cronbach's alpha. Results: Professors from 7 types of healthcare occupation were investigated for their opinions on the introduction of the SBT system ; 65.9% of the professors answered positively on the introduction of the SBT National Examination System, while 40.1% of the clinical experts answered likewise. In particular, professors and the clinical experts recognized altogether that the multimedia questionnaire, being effective for the evaluation of clinical and practical competence of the subjects, enabling the evaluation of various areas and strengthening the school education in clinical practices, the 42.0% of the students from 7 departments answered that the future direction of the national test is in the SBT test system with significant difference (p=.000) found in students majoring in order of Emergency Medical Services, Radiology and Physical therapy, compared to students from other majors, showing the positive response to the SBT system. Conclusion: The results of this study comprehensively evaluated the positive recognition of development of multimedia items and SBT system in national examination of 7 types of healthcare occupation in professors, field specialists and students.

Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography (치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과)

  • Lee, Tae Hui;Jeong, Seung Hun;Kim, Dong Woo;Park, Myeong Hwan;Kim, Tae-Hyung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.459-464
    • /
    • 2019
  • In order to minimize the radiation exposure dose of the thyroid site at dental cone-beam computer tomography, a protector using a Bolus was prepared, and the radiation shielding effect and the appropriateness of the image were evaluated. Using a dental cone-beam computed tomography (CBCT), a glass dosimeter was attached to the left and right sides of the thyroid for a dental radiation phantom, and the radiation dose was measured. The absorbed dose for each shield was measured by another method to 10 mm, 20 mm, and 30 mm-thickness, respectively. Eight evaluators evaluated whether or not the medical image is appropriate. When using a 30 mm Bolus shield at the left thyroid site, the resulting value is reduced by an average of $342.67{\mu}Gy$ by 20.7% from the average value of $431.22{\mu}Gy$ measured without using a Bolus shield, the right thyroid site In the case of using 30 mm Bolus shield, it showed a dose reduction effect of 21.9% with an average of $424.56{\mu}Gy$. The adequacy of the medical image was judged to be usable by both evaluators. In conclusion, the dental cone-beam computerized tomography can be used as a useful shielding material because it has a radiation shielding effect and it is possible to treat the diagnosis of the bolus protector in the thyroid without any obstruction shade in order to minimize the radiation dose.

Factor analysis using S-detect Method in Breast Ultrasound (유방 초음파 검사 시 S-detect 방법을 활용한 인자 분석)

  • Chun, Hye Ri;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • This study aimed to investigate the performance of the S-detect method in breast ultrasonography and to determine how to reduce unnecessary biopsy by comparing the results of the S-detect method and biopsy. Thirty patients who had undergone breast ultrasonography between August and October 2018 and were scheduled to undergo biopsy because of the presence of breast nodules were retrospectively analyzed. The McNemar test was performed to determine whether detection of a malignant breast mass significantly differed between the S-detect method and biopsy. The following results were obtained from the analysis of the S-detect method: sensitivity, 90.9%; specificity, 84.21%; validity, 86.66%; positive predictive value, 76.92%; and negative predictive value, 94.11%. Analysis of the degree of agreement between the S-detect method and biopsy revealed a kappa value as high as 0.724 (p < 0.05), exhibiting good agreement between the two methods. The S-detect method in breast ultrasonography is diagnostically valuable in terms of distinguishing between malignant and benign breast masses, and if used properly before breast biopsy, unnecessary biopsy can be reduced.

Effects of Blood Factors on Coronary Artery Calcification Scores (혈액인자가 관상동맥 석회화 수치에 미치는 영향)

  • Park, Mi Jeong;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.337-344
    • /
    • 2021
  • Coronary artery calcification is associated with cardiovascular risk factors and metabolic syndrome, and several studies have already reported that coronary artery calcification score are closely related to the amount of atherosclerotic plaques. This study was conducted on 109 patients who underwent coronary calcium CT who visited the comprehensive health examination center in Daegu city during the period from December 2020 to February 2021. we would like to investigate the relationship between coronary artery calcification score and blood factors. As a result of the study, the abnormal group increased the risk of calcification by 1.113 times compared to the normal group in the waist circumference factor. In the fasting glucose factor, the abnormal group increased the risk of calcification by 1.036 times compared to the normal group, and in the triglyceride factor, the abnormal group was normal. As the risk of calcification increased 1.008 times compared to the group, the waist circumference factor, fasting glucose factor, and triglyceride factor were found to be factors affecting coronary artery calcification score. The risk of developing calcification is primarily associated with waist circumference, anemia and triglycerides, and health care and health checks are expected to help reduce the incidence of cardiovascular disease and reduce medical costs.

Evaluation of Distortion in Measuring the Stability of Distal Radio-ulnar Joint in Wrist PA-Grip View (Wrist PA-grip view에서 먼쪽노자관절의 안정성 정도 측정 시 왜곡도 평가)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.321-327
    • /
    • 2021
  • Wrist PA-grip view is used to diagnose triangular fibrocartilage complex (TFCC) tear because it can easily diagnose damage to the surrounding wrist ligaments. However, despite advances in radiology equipment, distortion of images due to geometric elements still has many limitations. In this paper, we propose a method that can minimize the distortions of images by analyzing the distortions occurring in the wrist PA-grip view. A source of image distance (SID) were set at 130 cm and 150 cm for comparison with 110 cm. Depending on the SID, the phantom of wrist was moved at 0, 2, 4, 6, 8, and 10 cm in the X-axis and Y-axis directions, respectively. For quantitative evaluation, the difference of distance between the radius and ulna was measured in picture archiving and communication system (PACS) system. As a qualitative evaluation, survey was conducted among 20 radiologic technologists who examined the Wrist PA-grip view. The Kruskal Wallis test was performed to compare the distortion according to the phantom movement in the X-axis and Y-axis directions based on the SID, and the Tukey test was performed as a post-test. In the quantitative evaluation results, the measured values obtained in the X-axis was not significantly different in all groups (p>0.05). The measured values obtained in the Y-axis was significantly different in the most groups (p<0.05). Therefore, to reduce distortion while maintaining image quality, we recommend what examine the SID at 150 cm than 110 cm.

Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist (방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도)

  • Kim, Eun-Hye;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Moon, Young-Ju;Kim, Hoon;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Cho, Pyong-Kon;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.