Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention (심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구)

  • Kim, Jungsu;Kwon, Soonmu;Jung, Haekyoung;Lee, Bongki;Ryu, Dongryeol;Kwon, Hoseok;Cho, Byungryul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • Cardiac angiography(CA) or cardiac intervention(CI) is one of the major examination methods applied to the detection of cardiovascular diseases using X-rays. These CA and CI procedures require radiation exposure to patients and physicians. We evaluated the radiation dose to cardiac operator during the each case of CA and CI procedures. The number of patients is 113 patients in CA and 34 patients in CI. Mean fluoroscopy time, mean cine time, and mean total cumulative dose area product(DAP) in patients during CA and CI was 165.9 sec vs. 1200.0 sec, 30.31 sec vs 107.5 sec, and $37130.3mGy.cm^2$ vs $213312.6mGy.cm^2$, respectively. Mean dose of thyroid, over chest apron and under chest apron in operator during CA and CI was 15.84 uSv vs 89.81 uSv, 20.16 uSv vs 123.20 uSv, and 0.30 uSv vs 2.40 uSv, respectively. Mean effective dose of operator during CI was about 6 times greater than during CA. Also there was significant inter-relationship between fluoroscopy or cine time and effective dose in operator during CA and CI(p=0.001 and p=0.001, respectively).

The mechanism of chondrogenesis inhibition by X-Irradiation (X선에 의한 연골세포 분화 억제 작용경로)

  • Ha, Jong-Yeol;Lim, Young-Bin;Lee, Yoon-Ae;Sonn, Jong-Kyung;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.91-97
    • /
    • 2003
  • The purpose of this study is to investigate the mechanism of inhibition of chondrogenic differentiation by X-irradiation. Cultures of chick limb bud mesenchymal cells were exposed to various dose of X-ray and chondrogenesis was examined. X-irradiation inhibited accumulation of proteoglycan based on the observation of alcian blue staining and expression of chondorcyte specific-type II collagen. X-irradiation also inhibited expression of protein kinase $C{\alpha}$ while expression of $PKC{\lambda}({\iota}),\;{\varepsilon}$ was not altered. Expression of Erk-1 was not changed by X-irradiation but phosphorylation of Erk-1 was increased. In addition, inhibition of Erk-1 phosphorylation by PD98059 overcame inhibitory effect of X-irradiation on the chondrogenic differentiation. PNA staining data showed that X-irradiation inhibited cellular aggregation. Taken together, these results suggest that X-irradiation inhibits chondrogenic differentiation by inhibiting cellular aggregation and suppressing expression of $PKC{\alpha}$ and promoting phosphorylation of Erk-1. In addition to above pathway, our results also suggest that X-irradiation may exerts its inhibitory effect by another signaling pathways.

  • PDF

Macrobenthic Community on Angol Tidal Flat in Jinhae (진해 안골조간대에 서식하는 대형저서동물의 군집구조)

  • Paik Sang-Gyu;Yun Byoung Sun;Kim Kgu Hwan;Yun Sung Gyu
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.2 s.58
    • /
    • pp.106-113
    • /
    • 2005
  • This study was conducted to examine the community structure of macrobenthos on Angel tidal flat in Jinhae, south coast of Korea. Monthly samples were conducted at eight sites from March 1998 to February 1999. A total of 110 species were sampled with a mean density of 322ind. $m^{-2}$ and biomass of 98.4 wwt g $m^{-2}$. Of these species, there were 44 species of polychaetes $(40.0\%)$, 41 species of crustaceans $(37.3\%)$ and 16 species of molluscs $(14.5\%)$. The major density dominant species were a gastropod Batilaria cumingi (52ind. $m^{-2}$) and five polychaetes Ceratonereis erythraeensis (38ind. $m^{-2}$), Cirriformia tentaculata (32ind. $m^{-2}$), Capitella capitata (23ind. $m^{-2}$), Sigambra tentaculata (23ind. $m^{-2}$), Glycera chirori (17ind. $m^{-2}$). Cluster and MDS analysis showed that the study sites could be divided into two tidal elevation groups. According to the spatial distribution of dominant species and SIMPER analysis, the two groups were characterized by Sigambra tentaculata - Chaetozone setosa in upper species group and Ceratonereis erythraeensis-Cirriformia tentaculata-Capitella capitata in lower species group.

Growth of Li2B4O7 Single Crystal and Its Thermoluminescent Properties (Li2B4O7 단결정 성장과 열형광 특성)

  • Park, Kang-Soo;Ahn, Jung-Keun;Kim, Dong-Jin;Hwang, Yoon-Hwae;Kim, Hyung-Kook;Park, Myeong-Hwan;Kang, Hee-Dong;Kim, Do-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.16-23
    • /
    • 2003
  • Thermoluminescent properties of $Li_2B_4O_7$ single crystal grown by Czochralski method have been investigated. The high quality $Li_2B_4O_7$ single crystal without core was obtained at rotation speed of 10 rpm for seed crystal and pulling speed below $0.18\;mm{\cdot}h^{-1}$. The structure of $Li_2B_4O_7$ single crystal was classified as tetragonal by XRD analysis. The TL glow curve was composed with three overlapped peaks which can be easily deconvoluted and the TL response of $Li_2B_4O_7$ single crystal TLD to X-ray radiation is linear within the range of $50\;mGy{\sim}1.5\;Gy$. Activation energies of three TL glow peaks analyzed by the various heating rates method and PL spectrum were 0.93, 1.78 and 2.25 eV, respectively.

Survey on Radiographic Works in Hospitals and Clinics (병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査))

  • Choi, Song-Hak;Jeon, Man-Jin;Park, Sung-Ock;Lim, Han-Young;Kim, Keon-Chung;Huh, Joon;Choi, Jong-Woon
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • The major findings of this investigation on radiographic works in 125 medical institutions around Seoul and Kyung-Ki area, from March 1983 to February 1984, are summarized as follows. 1. The number of references provided on radiographic techniques were 3 to 5 in general hospitals (52.1%), in hospitals (58.5%), and clinics (44.5%), and only the 10.4% of general hospitals had 11 or more. 2. The relatively high percentages of 75.0% of general hospitals and 68.3% of hospitals have established the standardized radiographic methods for regions examined, but most clinics (61.1%) have not. 3. As a log system for the radiographic request, the method of "routine study, or all the x-ray examinations are marked as 0 on a printed form" was most commonly used by general hospitals (62.5%) and hospitals (51.2%), and "the doctors employ their own methods" in most clinics (44.6%). 4. In the 85.4% of general hospitals, the 68.3% of hospitals and the 38.9% of clinics, the data such as diagnosis, clinic history, purpose of x-ray examination were recorded on a radiographic request at all times, or at least in part. 5. On a scale of hardness and easiness of order of doctors, the greatest response was "fairly easy to understand", and the 37.5% of general hospitals responded as "sometimes hard". 6. In determining the standards for radiographic factors, the general hospitals (62.5%) and hospitals (65.9%) adapted mostly "a departmental check list", and the clinics (61.1%) used mainly "a personal decision". 7. In using the immobilizing devices, angligner, and radiographic accessories, the Percentages were high in general hospitals and hospitals on the one hand, and were low in clinics on the other. 8. A consideration with regard to the devices for an improvement of examination of the same patients was totally ignored by the 50.0% of clinics, the 26.8% of hospitals and the 20.8% of general hospitals. 9. The causes of re-examination were due largely to patients (33.6%), and followed proportionately by incorrect exposure (22.8%), errors in positioning (22.0%), film processing faults (9.2%), conditions of x-ray equipments (8.8%), and quality of x-ray films (3.6%). 10. The conference on radiography was conducted regularly or irregularly by the 87.5% of general hospitals, the 56.1% of hospitals, and the 27.7% of clinics, and the meeting was proceeded only by radiologic technologists.

  • PDF

Estimate of Radiation Doses in MDCT Using Patient Weight (MDCT 검사에서 환자 체중을 이용한 선량 평가)

  • Kwon, Seong-Ohk;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Choi, Ji-Won;Chung, Woon-Kwan
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2010
  • The purpose of this study provides measurements of radiation dose from MDCT of head, chest, abdomen and pelvic examinations. A series of dose quantities that are measured of patient weight to compare the dose received during MDCT examinations. Data collected included: weight together with CT dose descriptors, volume CT dose index (CTDIvol) and dose length product (DLP). The effective dose was also estimated and served as collective dose estimation data. Data from 1,774 adult patients attending for a CT examination of the head (n=520) or chest (n=531) or abdomen (n=724) was obtained from spiral CT units using a same CT protocol. Mean values of CTDIvol was a range of 48.6 mGy for head and 6.9, 10.5 mGy for chest, abdomen examinations, respectively. And mean values of DLP was range of 1,604 $mGy{\cdot}cm$ for head, 250 $mGy{\cdot}cm$ for chest, 575 $mGy{\cdot}cm$ for abdomen examinations, respectively. Mean effective dose values for head, chest, abdominal CT were 3.6, 4.2, and 8.6 mSv, respectively. The degree of CTDIvol and DLP was a positive correlation with weight. And there was a positive correlation for weight versus CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694) in chest. And head was also positive correlation with weight versus CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741). We conclude that CTDIvol and DLP is an important determinant of weight within the CT examinations. The results for this study suggest that CT protocol should be tailored according to patient weight.

Change of Morphologic Pelvis and Deviation According to Gender, Age -Radiological Pelvimetry- (성별과 나이에 따른 골반 형태 변화와 골반 변위 -방사선영상을 이용한 골반 계측-)

  • Kang, Yeong-Han;Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to analyze the change of morphologic pelvis according to age and gender. Pelvis AP(anterior-posterior) projection were taken from 382 individuals (men: 194, women: 188) at the age of twenty and older. We measured four values of pelvis using CR (computed radiological system) including maximum pelvic breadth (MPB), sacral breadth (SB), transverse diameter of pelvic inlet (TD), and distance between femoral heads (DFH). Average (t-test, ANOVA) and Pearson correlation were calculated for comparison. While there was no significant difference of gender in case of MPB, significant differences were observed in SB (men 97.76 mm, women 102.00 mm), TD (men 138.0 mm, women 149.79 mm), and DFH (men 141.94 mm, women 150.39 mm). The DFH values were negatively correlated with the age (men r=-0.280, women r=-0.207). The morphological changes of pelvis were measured high in the men of 50's and in the women of 60's and 70's. The SB, TD and DFH were greater in the women than in the man. As the ages get higher, the deviation of pelvis were gradually increased, which indicates that the morphological changes of pelvis with respect to the age reflects an aging process.

A Study on the Surface Dose Distribution by Scattered and Leakage Radiation in Radiation Therapy (방사선 치료 시 산란선 및 누설선에 의한 표면선량 분포에 관한 연구)

  • Kang, Jongsu;Jung, Dongkyung;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.351-357
    • /
    • 2018
  • During radiation therapy, the patient is exposed to secondary radiation by scattered and leakage radiation. For the diagnostic radiation, guidelines for reducing the patient's exposure as the diagnostic reference level are provided. However, in the case of therapeutic radiation, even though the radiation dose by the secondary radiation is considerable, the prescription dose is not limited because of the reason of the therapeutic efficiency. The purpose of this study was to evaluate the secondary radiation that the patient could be received at the peripheral tissue during the radiotherapy using the linear accelerator with the radiophotoluminescent glass dosimeter. In addition, we measured the degree of saturation of the luminescent amount according to the build-up characteristic of the radiophotoluminescent glass dosimeter. As a result of carrying out this study, the exposure dose decreased drastically farther away from the treatment field. When the head was irradiated with 1 Gy, the neck could be exposed to 18.45 mGy. When the same dose was irradiated at the neck, 15.55 mGy of the head and irradiated at the chest, 14.26 mGy of the neck and irradiated at the pelvis, 1.14 mGy of the chest were exposed separately. The degree of saturation of the luminescent intensity could be overestimated by 1.8 ~ 4.8% depending on time interval for 3 days.

Design and Application of Acrylic Electron Wedge for Improving Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 acrylic electron wedge의 제작 및 사용)

  • Kim, Young-Bum;Kwon, Young-Ho;Whang, Woong-Ku;Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.36-42
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20%$) at the region of junction of fields. In this study, we made Acrylic Electron Wedges to improve dose inhomogeneities(${\pm}5%$) in these junction areas and to apply it to clinical practices. All measurements were made using 6, 9, 12, 16, 20 MeV Electron beams from a linear accelerator for a $10{\times}10\;cm$ field at 100cm of SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm acquires central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance according to the acryl insert, e.g. a 1 mm thick acryl insert reduces the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced to approximately 0.2 MeV. These effects were almost Independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase(less than 3%) in the surface dose and a small increase(less than 1%) in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction at the point of penumbra width($35\;mm{\sim}40\;mm$). We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be used to improve dose uniformity at electron field junctions and it will be effectively applied to clinical practices.