• 제목/요약/키워드: Radiologic Science

검색결과 479건 처리시간 0.021초

Radiologic assessment of bone healing after orthognathic surgery using fractal analysis

  • Park Kwan-Soo;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Jeon In-Seong;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • 제32권4호
    • /
    • pp.201-206
    • /
    • 2002
  • Purpose : To evaluate the radiographic change of operation sites after orthognathic surgery using the digital image processing and fractal analysis. Materials and Methods : A series of panoramic radiographs of thirty-five randomly selected patients who had undergone mandibular orthognathic surgery (bilateral sagittal split ramus osteotomy) without clinical complication for osseous healing, were taken. The panoramic radiographs of each selected patient were taken at pre-operation (stage 0), 1 or 2 days after operation (stage 1), 1 month after operation (stage 2), 6 months after operation (stage 3), and 12 months after operation (stage 4). The radiographs were digitized at 600 dpi, 8 bit, and 256 gray levels. The region of interest, centered on the bony gap area of the operation site, was selected and the fractal dimension was calculated by using the tile-counting method. The mean values and standard deviations of fractal dimension for each stage were calculated and the differences among stage 0, 1, 2, 3, and 4 were evaluated through repeated measures of the ANOVA and paired t-test. Results : The mean values and standard deviations of the fractal dimensions obtained from stage 0, 1, 2, 3, and 4 were 1.658±0.048, 1.580±0.050, 1.607±0.046, 1.624±0.049, and 1.641 ±0.061, respectively. The fractal dimensions from stage 1 to stage 4 were shown to have a tendency to increase (p < 0.05). Conclusion: The tendency of the fractal dimesion to increase relative to healing time may be a useful means of evaluating post-operative bony healing of the osteotomy site.

  • PDF

전산화 단층촬영을 이용한 법랑모세포종의 방사선학적 연구 (A radiologic study of ameloblastoma using computed tomography)

  • 박혁;정호걸;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제35권2호
    • /
    • pp.77-82
    • /
    • 2005
  • Purpose : To reveal what is the distinct differential diagnostic differences between unicystic ameloblastoma and solid or multicystic ameloblastoma. Materials and Methods : 56 cases of ameloblastoma were retrospectively reviewed and evaluated among the patients who had taken CT scans at the department of Oral & Maxillofacial Radiology in Yonsei University Dental Hospital from January 1996 to December 2003. Results : In 56 cases, 21 cases $(37.5\%)$ were unicystic ameloblastoma, 35 cases $(62.5\%)$ were solid or multicystic ameloblastoma. Only 1 case $(4.8\%)$ of unicystic ameloblastoma and 4 cases $(11.4\%)$ of solid or multicystic ameloblastoma were occurred in maxilla. 13 cases $(61.9\%)$ of unicystic ameloblastoma were observed as unilocular, and 8 cases $(38.1\%)$ as lobulated. 5 cases $(14.3\%)$ of solid or multicystic ameloblastoma were observed as unilocular, 13 cases $(37.1\%)$ as lobulated, and 17 cases $(48.6\%)$ as multilocular. Tn the results from the measurements after correction of the buccolingual widths and heights to the mesiodistal lengths, there is a statistically significant difference between unicystic ameloblastoma and solid or multicystic ameloblastoma in ANCOVA test (p<0.05). Hounsfield units in the lesion were $24.9{\pm}8.8\;HU$ in unicystic ameloblastoma, $31.2{\pm}11.5\;HU$ in solid or multicystic ameloblastoma. There is no statistically significant difference (p>0.05). Conclusion : Characteristic differences between unicystic ameloblastoma and solid or multicystic ameloblastoma is that there is higher prevalence of solid or multicystic ameloblastoma that have lobulated or multilocular patterns. To measure the Hounsfield units in the lesion is helpful, but it is not a differential diagnostic point between unicystic ameloblastoma and solid or multicystic ameloblastoma.

  • PDF

다발성 연조직 종괴를 동반한 급성 림프구성 백혈병의 증례 보고 (Case report of acute lymphoblastic leukemia with multiple soft tissue mass)

  • 장정용;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권2호
    • /
    • pp.111-114
    • /
    • 2005
  • A 15-year-old patient, who had been diagnosed and treated as Burkitt cell type acute lymphoblastic leukemia (ALL-L3) already, visited our department. He complained of gingival enlargement and loosening teeth 1 month ago. The clinical examination revealed anterior open bite, gingival enlargement, and nontender swelling particularly in molar regions of both jaws. Deep periodontal pockets and severe mobility was shown on most of the teeth. The panoramic radiographs showed severe bone destruction and extrusion of the molars. The contrast enhanced CT showed multiple enhanced mass and bone marrow obliteration in both jaws. Chemotherapy was done and the swelling was subsided at 1 month later. In conclusion, radiologic findings of leukemia with soft tissue mass, known as chloroma or granulocytic sarcoma, mimic those of lymphoma, so blood test may be needed for the final diagnosis.

  • PDF

Scannogram, Whole Spine image 획득에 관한 연구 (The Research for Scannogram)

  • 이광재;고신관;김욱동;김시돈;김형섭
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.35-40
    • /
    • 2008
  • I.objective The composition method with acquiring 2${\sim}$5 image not only lack perfection in compensating the geometrical distortion but could also cause inaccurate connection problem of compensating the geometrical distortion but could also cause inaccurate connection problem of continuing bone structure due to the enlargement ratio difference of ruller and bone, density difference in image composition process. This paper studies those mentioned problems through the experiments. II. Object and method Experiment 1 After attaching 3 step wedge(Pb) on detector and 2 ruller on upper, lower part of the step wedge, we have exposed them to create density difference between 1st image and 2nd image, then examined if there were any errors. Experiment 2 1st 100cm ruller was attached on the center of detector, and by escalating the distance between 2nd 100cm ruller and detector 5cm, 10cm, 15cm respectively, we investigated if there any errors caused by enlargement ratio. Experiment 3 The ruller was placed on detector, a joint photographing was performed through spot photographing after fully operating the electric field photographing to include hip joint ${\sim}$ ankle joint part and we have compared the values from two methods. III. Result : A horizontal axis error was caused when photopraphing is not poerated in equal density since the image shifted horizontally in accordance with the difference of Pb step wedge 1 due to the density difference, as the result of Epperiment 1.

  • PDF

Reference based simulation study of detector comparison for BNCT-SPECT imaging

  • Kim, Moo-Sub;Shin, Han-Back;Choi, Min-Geon;Monzen, Hajime;Shim, Jae Goo;Suh, Tae Suk;Yoon, Do-Kun
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.155-163
    • /
    • 2020
  • To investigate the optimal detector material for prompt gamma imaging during boron neutron capture therapy, in this study, we evaluated the characteristic regarding radiation reaction of available detector materials using a Monte Carlo simulation. Sixteen detector materials used for radiation detection were investigated to assess their advantages and drawbacks. The estimations used previous experimental data to build the simulation codes. The energy resolution and detection efficiency of each material was investigated, and prompt gamma images during BNCT simulation were acquired using only the detectors that showed good performance in our preliminary data. From the simulation, we could evaluate the majority of detector materials in BNCT and also could acquire a prompt gamma image using the six high ranked-detector materials and lutetium yttrium oxyorthosilicate. We provide a strategy to select an optimal detector material for the prompt gamma imaging during BNCT with three conclusions.

PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구 (The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment)

  • 정재호;김은수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.147-153
    • /
    • 2014
  • 디지털 Mammography영상에서 압축률에 따른 화질의 특성에 대해 정량적 평가와 정성적평가를 실시하였다. ACR Accreditation phantom을 대상으로 JPEG2000, JPEG 압축알고리즘을 적용하여 압축한 후 Detection Score를 측정하여 압축률에 상관없이 10점 인정기준을 충족하였다. 또한 실제미세병소 영상을 선정하여 압축을 실시하여 확대율에 따른 진단능의 변화를 측정하여 20:1 이상 압축 후 50% 이상 확대 시 진단능에 영향을 미칠 수 있음을 알 수 있었다. 또한, 정량적 평가방법인 PSNR, RMSE, MAE, SSIM등을 측정하여 압축률에 따른 원본영상과의 차이점은 비교적 허용 가능한 오차범위 내의 값이 측정되었다. 또한 MTF 측정을 통해 Full Field Digital Mammography 영상의 화질이 진단에 적합한 영상임을 알 수 있었다.

초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰 (Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy)

  • 이훈정;강성진
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1057-1064
    • /
    • 2021
  • 본 연구는 초음파 조직검사 시에 실내 공기 중 HCHO 농도변화를 관찰하고자 실제 조직검사와 동일한 환경조건을 모사하여 진행하였다. 초음파 검사실의 밀폐, 환기, 포르말린 용기 개봉, 포르말린 용기 밀봉, 재환기의 다섯 단계를 연속적으로 진행하며 실내의 HCHO 농도변화를 측정하였다. 측정한 HCHO 농도변화는 그래프를 이용하여 시각화하였다. 3회에 걸쳐 측정된 농도 변화값의 일치도를 급내상관계수를 이용하여 분석한 결과, 상관계수 값이 0.989로 통계적으로 유의한 결과를 나타내었다(p<0.05). 연구 결과를 토대로 영상의학적 검사 분야에서 HCHO의 노출 환경 내에 근무하고 있는 의료종사자들 스스로 업무 중 노출 관리 필요성에 대한 인식개선과 더불어 노출 관리를 위한 환경구축 및 대책 마련에 대하여 적극적인 논의가 이루어지길 바란다.

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

Technegas 스캐닝 후 중력환기에 의한 공간선량율 측정 (The Measurement of Spatial Dose Rate by Gravity Ventilation after Technegas Scanning)

  • 김성빈;원도연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.667-674
    • /
    • 2019
  • Technegas를 사용한 검사는 단순 확산 누적을 통해 폐 영상을 이미지화하기 때문에 검사를 마친 후에 검사실이 오염될 수 있다. 따라서 방사선 작업 종사자와 검사를 기다리는 환자는 technegas 흡입으로 인한 내부 피폭의 영향을 받게 된다. 이에 중력환기 전후의 시간경과에 따른 공간선량율 분포를 비교, 분석함에 따라 방사선사, 의료진, 대기 환자의 피폭선량 저감화 방법을 모색하고자 한다. 중력환기 전후 환자의 호흡기 위치에서 거리별, 각도별로 공간선량율을 10분 동안 측정하고 평균값, 표준 편차 및 감소율을 계산하였다. 실험 결과, 중력 환기 전후 감소율은 최고 95.31%였고 가장 높은 감소율은 1 ~ 3분 사이에서 나타났다. 중력환기를 통해서 방사선 작업종사자, 대기환자, 환자 보호자 및 간호사의 피폭선량을 감소시킬 수 있다. 결론적으로 중력환기를 통한 피폭선량 감소 결과는 방호 최적화를 이루는 역할을 할 것이며 ICRP 103에서 권고한 의료 피폭 저감화에 부합된다.

소아 환자에서 방사선 차폐체로 인한 피폭선량과 화질의 변화 (Changes in Exposure Dose and Image Quality due to Radiation Shielding in Pediatric Patients)

  • 이영희;이용기
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.931-936
    • /
    • 2020
  • 본 연구는 자동노출선량장치을 사용했을 때 생식선 차폐체의 유무와 크기 변화에 따른 소아 환자의 방사선 피폭선량과 화질의 변화를 관찰하기 위하여 수행되었다. X-ray 장비를 이용하여 소아 팬텀의 복부와 생식선에서 차폐체가 없을 때와 3가지 크기의 차폐체를 사용했을 때의 방사선 피폭선량을 측정하였으며, 얻어진 영상을 통하여 SNR과 CNR을 측정하였다. 연구 결과 방사선 차폐체의 크기에 비례하여 생식선의 방사선 피폭선량은 감소하였으나 복부의 방사선 피폭선량은 오히려 증가되는 것으로 나타났으며 화질의 변화는 나타나지 않았다. AEC System 사용으로 인하여 방사선 차폐체로 인하여 증가된 방사선으로 인하여과 피폭되지 않도록 소아 환자의 연령과 몸무게, 신체 크기에 최적화된 크기의 차폐체를 사용하는 것이 효과적이라는 것을 확인할 수 있었다.