• Title/Summary/Keyword: Radiologic Science

Search Result 480, Processing Time 0.024 seconds

Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography (방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가)

  • Choi, Woo Cheol;Kim, Yongmin;Kim, Jung Su
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

A Study of Diagnostic Reference Levels for Coronary Angiography and Percutaneous Coronary Intervention in Gyeongsang Area (관상동맥 조영술 및 경피적 관상동맥 중재술에 대한 진단참고준위에 관한 연구; 경상도지역중심)

  • Si-Wang Lim;Jung-Su Kim;Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.123-129
    • /
    • 2023
  • Interventional cardiology procedures can involve relatively high radiation doses compared to conventional radiography. During CAG, CAG + PCI and PCI the same area is exposed to radiation for a long period. In this study, radiation exposure data of 421 examinations in Gyeongsang area were collected, and the DRLs and ADs in actual medical practice for three types of interventional cardiology procedures in Korea were established. In CAG 286 case, 75th percentile DRLs and ADs of the total DAP were 55.89 Gy·cm2 and 37.47 Gy·cm2 , respectively. In CAG + PCI 92 case, those values were 222.84 Gy·cm2 and 117.51 Gy·cm2 respectively. In PCI 43 case, those values were 198.73 Gy·cm2 and 120.13 Gy·cm2 respectively. In this study, for the first time, the diagnostic reference level of interventional cardiology procedures in Gyeongsang area were established. Using the diagnostic reference level of interventional cardiology procedures derived from this study, it will help to identify and improve the level of exposure dose in the region and country.

Polyostotic Fibrous Dysplasia of Cranio-Maxillofacial Area (두개 악안면 부위에 발생한 다골성 섬유성이형성증)

  • Han Jin-Woo;Kwon Hyuk-Rok;Lee Jin-Ho;Park In-Woo
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.149-154
    • /
    • 2000
  • Fibrous dysplasia is believed to be a hamartomatous developmental lesion of unknown origin. This disease is divided into monostotic and polyostotic fibrous dysplasia. Polyostotic type can be divided into craniofacial type, Lichtenstein-Jaffe type, and McCune-Albright syndrome. In this case, a 31-year-old female presented spontaneous loss of right mandibular teeth before 5 years and has shown continuous expansion of right mandibular alveolus. Through the radiographic view, the coarse pattern of the mixed radiopaque-lucent lesion was seen on the right mandibular body, and there was diffuse pattern of the mixed radiopaque-lucent lesion with ill-defined margin in the left mandibular body. In the right calvarium, the lesion had cotton-wool appearance. Partial excision for contouring, multiple extraction, and alveoloplasty were accomplished under general anesthesia for supportive treatment. Finally we could conclude this case was polyostotic fibrous dysplasia of cranio-maxillofacial area based on the clinical, radiologic finding, and histopathologic examination.

  • PDF

Ultrastructure of Spermatozoa of a Korean Bitterling, Acheilognathus koreensis (Pisces, Cyprinidae) (한국산 잉어과어류 칼납자루(Acheilognathus koreensis) 정자의 미세구조)

  • Kim, Kgu-Hwan;Kim, Jeong-Ki;Hwang, Ki-Ju
    • Korean Journal of Ichthyology
    • /
    • v.19 no.4
    • /
    • pp.286-291
    • /
    • 2007
  • The bitterling, Acheilognathus koreensis spermatozoon has been examined by electron microscopy. The epididymal spermatozoa of A. koreensis are representing typical characteristic of cyprinid spermatozoa including the lateral insertion of flagellum, the organization of centriolar complex in shallow nuclear fossa and the asymmetrical arrangement of mitochondria. The sperm mid-piece contains a large mitochondrion characteristic enclosed by membranous vesicles. The mitochondria aspect is different from that of other cyprinid spermatozoa, which their mitochondria have a conventional aspect and never fuse to form a mitochondrial derivative. In term of sperm evolution, the fused mitochondria are regarded as the apomorphic character in comparison with the separate mitochondria. The single mitochondrion is not found in cyprinid spermatozoon except for Rodeus and Pungtungia.

Effect of Platycodin D on Airway MUC5AC Mucin Production and Gene Expression Induced by Growth Factor and Proinflammatory Factor

  • Lee, Hyun-Jae;Lee, Su-Yel;Jeon, Byeong-Kyou;Lee, Jae-Woo;Kim, Young-Sik;Lee, Mi-Nam;Lee, Choong-Jae
    • Biomolecules & Therapeutics
    • /
    • v.18 no.3
    • /
    • pp.294-299
    • /
    • 2010
  • In this study, we tried to investigate whether platycodin D significantly affects MUC5AC mucin production and gene expression induced by epidermal growth factor (EGF), phorbol ester (PMA) and tumor necrosis factor-$\alpha$ (TNF-$\alpha$) from human airway epithelial cells. Confluent NCI-H292 cells were pretreated with varying concentrations of platycodin D for 30 min and then stimulated with EGF, PMA and TNF-$\alpha$ for 24h, respectively. MUC5AC mucin gene expression and mucin protein production were measured by RT-PCR and ELISA. The results were as follows: (1) Platycodin D was found to inhibit the production of MUC5AC mucin protein induced by EGF, PMA, and TNF-$\alpha$, respectively. (2) It also inhibited the expression of MUC5AC mucin gene induced by the same inducers. These results suggest that platycodin D can regulate mucin gene expression and production of mucin protein, by directly acting on human airway epithelial cells.

Topical Application of 0.1% Tacrolimus Ointment for Treatment of Sinus Refractory Pododermatitis Secondary to Atopy in a Dog

  • Kim, Ha-Jung;Yoo, Jong-Hyun;Park, Chul;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.202-206
    • /
    • 2008
  • An 8-year-old, castrated male Shih-tzu was referred due to relapsing pododermatitis and generalized pruritus. On physical examination, right forepaw showed swelling and serosanguinous exudates from sinus tract on dorsal paw. There were no remarkable findings on complete blood count (CBC), serum chemistry, and radiologic examination. On cytological examination of exudates from sinus tract, phagocyted bacteria and numerous degenerative neutrophils were noted. Results of deep skin scraping and plucking hair examination were unremarkable. Skin biopsy was performed and ruled out other skin diseases. Histopathology showed epidermal hyperplasia and diffuse mononuclear cell inflammation in dermal layer. Moreover, pyogranulomatous inflammation was demonstrated in subcutaneous layer. This case was clinically diagnosed as pododermatitis secondary to atopic dermatitis (AD). Clinical signs of pododermatitis were gradually improved following topical application of tacrolimus 0.1% ointment. This case report describes that tacrolimus ointment can be applicable for the treatment of refractory pododermatitis.

Effects of Baicalin, Baicalein and Schizandrin on Airway Mucin Production Induced by Epidermal Growth Factor and Phorbol Ester

  • Lee, Hyun-Jae;Lee, Su-Yel;Kim, Young-Sik;Jeon, Byeong-Kyou;Lee, Jae-Woo;Bae, Heung-Seog;Lee, Choong-Jae
    • Biomolecules & Therapeutics
    • /
    • v.18 no.4
    • /
    • pp.396-401
    • /
    • 2010
  • We conducted this study to investigate whether baicalin, baicalein or schizandrin significantly affect MUC5AC mucin production induced by epidermal growth factor (EGF) or phorbol ester (PMA) in human airway epithelial cells. Confluent NCI-H292 cells were pretreated with varying concentrations of baicalin, baicalein or schizandrin for 30 min and then stimulated with EGF or PMA for 24 h, respectively. MUC5AC mucin protein production was measured by ELISA. The results were as follows: (1) Baicalin was found to inhibit the production of MUC5AC mucin protein induced by both EGF and PMA. (2) Baicalein, the aglycone of baicalin, also inhibited MUC5AC mucin production. (3) Schizandrin, derived from Schizandrae Fructus, inhibited MUC5AC mucin production by the same inducers. These results suggest that baicalin, baicalein and schizandrin can regulate the production of mucin protein by directly acting on human airway epithelial cells.

Detection of Extravasated Contrast Media Using an Infrared Ray Based Extravasation Detection Accessory System (적외선 기반의 혈관외유출 검출시스템을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.412-417
    • /
    • 2009
  • The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The extravasation detection accessory (EDA) system was based of infrared ray with detection sensor, an amplifier, alarm device, receiver, cable and a computer based system. This study was a prospective, observational study in which the EDA system was used to monitor the automated mechanical injection of contrast media. Three hundred patients referred for contrast media enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically important extravasation. There were 8 true-positive cases, 276 true-negative cases, 15 false-positive cases and 1 false-negative cases. The EDA system had a sensitivity of 88.8% and a specificity of 94.8% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

Scintillation properties of BaCl2 crystal (BaCl2 결정의 섬광특성)

  • Doh, Sih-Hong;Kim, Jung-In;Kim, Hong-Joo;Kang, He-Dong;Kim, Sung-Hwan;Oh, Moon-Young
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.217-222
    • /
    • 2008
  • $BaCl_2$ crystals were grown by using the Czochralski method, and their scintillation properties were measured. The emission spectrum was located in the range of $370{\sim}450$ nm, peaking at about 400 nm. The fluorescence decay time was approximately 75.9 ns for 662 keV ${\gamma}$-rays excitation. The energy resolution was about 24.4 % for $^{137}Cs$ 662 keV ${\gamma}$-rays, and the ${\alpha}/{\beta}$ ratio to $\alpha$ particles from a $^{210}Po$ 5.4 MeV was about 0.25.