• 제목/요약/키워드: Radiologic Science

검색결과 479건 처리시간 0.031초

자기공명영상을 이용한 악관절내장증환자와 악관절증환자의 골변화에 관한 연구 (Evaluation of osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI)

  • 조수범;고광준
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.159-164
    • /
    • 2001
  • Purpose: To evaluate the osseous changes of TMJ in internal derangement and osteoarthritis patients using MRI. Materials and Methods: MR images of 111 TMJs in 64 patients were analyzed to evaluate the osseous changes, 111 TMJs were divided into 6 groups according to the radiologic Stages by Schellhas and Wilkes. On MR images, we evaluate the osseous changes of articular eminence and condylar head. Results: The most frequent Stage in internal derangement of TMJ was Stage I. And 28 joints (25.2%) revealed osteoarthritis with internal derangement. When osseous change of articular eminence and condylar head occur, flattening was the most common osseous change. Sclerosis was observed in all Stages and osteophytosis of condylar head was observed in Stage II (1.8%) and III (0.9%). Out of 28 joints with osteoarthritis, 6 joints (21.4%) showed joint effusion. Conclusion: MR image revealed abnormal configuration of disk, but the detection of minimal osseous change was subtle.

  • PDF

골단일 형질세포종 : 방사선학적 소견 (Solitary Plasmacytoma of the Bone: Radiologic Findings)

  • 윤춘식;김명준;안창수;서진석;신규호
    • 대한골관절종양학회지
    • /
    • 제6권2호
    • /
    • pp.61-68
    • /
    • 2000
  • 목적 : 골단일 형질세포종의 방사선 소견을 알아보고자 하였다. 대상 및 방법 : 최근 5년동안 골단일 형질세포종으로 진단받았던 9례의 방사선 소견을 후향적으로 검토하였다. 이 중 2례는 골수검사 소견의 이상으로 대상에서 제외되었고 다른 2례는 전산화단층촬영(1례)와 자기공명영상(1례) 소견의 이상 소견에 의해 대상에서 제외되었다. 결과 : 5례 중 4례에서 단순방사선검사상 경화성 변연이 없는 지도 모양의 골파괴 소견을 보였으며 대퇴골에서 발생한 1예는 골경화증 병변을 보였다. 전산화단층촬영과 자기공명영상 검사는 단순방사선검사에 비해 소주형성을 한 골파괴와 연부조직 침범 등 보다 많은 정보를 보여주었다. 4례의 자기공명영상에서 T 1강조영상에서는 비교적 고신호강도, T2강조영상에서 는 근육보다 약간 높은 중등도 신호강도를 보여주었다. 1례에서는 광범위한 연부조직 침범이 있었고, T1강조영상에서 같거나 저신호강도로, T2강조영상에서는 비균일한 고신호강도를 보이는 다발성 괴사가 있었다. 조영증상 T 1강조영상에서는 괴사부위를 제외한 병변의 강한 조영증강소견이 보였다. 결론 : 전산화단층촬영과 자기공명영상 검사는 골단일 형질세포종의 특징적인 소견의 일부를 보여줄 수 있고 형질세포 침윤이 있는 다른 부위를 찾을 수 있다. 이러한 것들이 골단일 형질세포종의 진단과 치료에 도움을 줄 수 있을 것이다.

  • PDF

소조사면 선량 계측을 위한 엣지검출기의 특성 분석 (Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry)

  • 장경환;이보람;김유현;최경식;이정석;박병문;배용기;홍세미;이정우
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.191-198
    • /
    • 2009
  • 이 연구의 목적은 소조사면 선량계측을 위하여 엣지검출기의 성능을 평가하기 위함이다. 다양한 소조사면과 깊이에서 엣지검출기(Model 1118 Edge)를 이용하여 6 MV 광자선의 선량 직선성, 선량률 의존도, 출력 계수, 선량 측면도 및 심부선량 백분율을 따라 측정하였으며, 이를 표준용적의 이온전리함(CC13)과 광자선 다이오드 검출기(PFD)와 비교하였다. 선량 직선성을 일차 선형 맞춤 함수와 비교하였을 때, 세 검출기 모두 1% 미만의 차이를 나타냈으며, 엣지검출기는 -0.08~0.08%의 가장 낮은 차이를 보였다. 선량율의 변화(100~600 MU/min)에 따라 PFD와 엣지검출기의 정규화된 반응비는 1% 미만의 일정한 값을 보였으나, CC13은 100 MU/min에서 약 -5%의 변화를 나타냈다. 조사면의 크기($4{\times}4\;cm^2{\sim}10{\times}10\;cm^2$)에 따른 출력계수는 세 검출기 모두 거의 같은 값을 보였으나, $4{\times}4\;cm^2$ 이하의 소조사면에서는 엣지검출기와 PFD의 출력 계수가 CC13과 최대 21%의 차이보였다. 각 조사면에서 20~80%의 반음영 폭을 측정하였을 때, 평균적으로 CC13은 엣지검출기보다 2배, PFD는 약 30% 정도 더 넓게 나타났다. 또한 10~90%의 반음영의 경우, CC13과 PFD가 각각 55%와 19% 정도 더 넓은 폭을 나타냈다. 엣지검출기는 선량 측면도의 반치폭이 조사면의 크기와 거의 일치하였으나, 다른 두 검출기는 조사면의 크기보다 약 8~10% 더 크게 나타났으며, 심부선량백분율은 각 조사면에서 세 검출기 모두 거의 일치하였다. 엣지검출기의 성능평가를 위한 선량특성을 분석한 결과, $4{\times}4\;cm^2$ 이하의 소조사면에서 가장 적합한 특성을 나타냈으며, CC13과 PFD와 같은 검출기는 조사면이 작을수록 상당한 오차를 나타낼 수 있음을 알 수 있었다.

  • PDF

방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구 (A Study on the Neutron in Radiation Treatment System and Related Facility)

  • 김대섭;김정만;이희석;임라승;김유현
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.141-145
    • /
    • 2005
  • 목 적 : 일반적으로 10 MV이상의 광자선에서 산란 중성자를 발생시키는 것으로 알려져 있다. 세관에 설치된 컨테이너 검색장치는 9 MV 이하였음에도 중성자가 누출되었다. 본 연구에서 의료기관에 설치된 방사선 치료기에서 산란 방출되는 중성자의 공간적인 측정을 통해 결과를 분석하고 평가하고자 한다. 대상 및 방법 : 본 연구의 방사선 발생장치는 의료용 선형가속기(linear accelerator, linac: Varian, Clinac 1800, USA)를 사용하였다. 중성자 측정용 검출기는 중성자가 발생하면 기포(bubble)이 생기는 Bubble 검출기(Bubble detector, BDPND type, BTI, Canada)를 사용하였다. 의료용 선형가속기 주변에 Bubble 검출기를 isocenter로부터 30 cm, 50 cm, 120 cm의 각각 3가지 거리별로 isocenter 상하 방향 네 곳에 위치시켜 측정하였다. 주변 구조물의 영향을 살펴보기 위해 Wedge와 Mount를 장착 후 50 cm 거리에서 각각 8방향에서 측정하였다. 광자선원부터 isocenter 까지의 거리(SAD: source-axis-distance)를 100 cm로 기준을 정하고 조사면의 크기(field size)는 $15{\times}15cm^2$로 정하였다. 방사선은 20 MU를 조사하여 Bubble 검출기에 발생한 기포수를 측정하며 mrem값으로 계산하였다. 결 과 : Isocenter부터 거리가 30 cm와 50 cm 떨어진 곳의 각각 8개 측정 지점 중에서는 모두 5번 위치(Gantry 우측 아래지점)에서 측정된 산란중성자의 양이 같은 거리라도 가장 높게 측정되었다. Bubble 검출기가 Isocenter부터 120 cm 떨어진 경우와 wedge를 장착한 경우는 7번 위치(Couch 우측 아래지점), mount 탈착한 경우는 2번 위치(Gantry 왼쪽 윗지점)에서 산란 중성자가 가장 높게 측정되었다. 결 론 : 산란중성자의 측정에서 직선상 같은 거리에 있는 곳이라도, 실제 측정한 결과 값에 따르면 서로 상이한 값을 보였다. 주변 구조물도 산란 중성자에 영향을 미치며, 직선상은 같은 거리라도 각각의 지점에서 다른 값을 보였다. 따라서, 산란중성자의 거리에 따른 영향은 단순히 직선으로의 거리뿐 아니라 방향과 주변 구조물에 대한 영향까지 고려하며 공간적인 측정과 평가가 필요하다.

  • PDF

팔꿉관절 측방향 일반촬영에서 아래팔뼈 각도 변화에 따른 영상 분석 : 위팔뼈 위관절융기와 팔꿉관절 평가 (Image Analysis of Angle Changes in the Forearm during Elbow Joint Lateral General Radiography: Evaluation of Humerus Epicondyle and Elbow Joint)

  • 신효수;장혜원;박종배;이기백
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.607-614
    • /
    • 2023
  • 팔꿉관절 측방향 일반촬영 검사 시 위팔뼈 양측 위관절융기의 정확한 겹침과 팔꿉관절의 적절한 분리는 매우 중요하다. 그러나 팔꿉관절의 복잡한 해부학적인 구조로 인해서 최적의 영상을 획득하기 어려워 반복적인 검사가 시행되고 있다. 따라서 본 연구는 팔꿉관절 측방향 일반촬영 검사 시 정확한 영상을 획득할 수 있는 환자의 각도를 조사하고자 하였다. 연구 대상은 20명의 환자로 정해진 연구 절차에 따라 시행되었다. 먼저 아래팔과 테이블 사이의 0°의 각도에서 X선을 수직 입사하여 영상을 획득하였다(대조군). 그 후, 팔꿉관절의 측방향 영상이 부적절하다고 판단될 경우 5° 및 10°의 기울기를 가진 스티로폼 지지대를 이용하여 아래팔의 각도를 조정하여 영상을 획득하였다(실험군). 평가 방법으로는 두 명의 평가자가 리커트 5점 척도를 통해 영상을 평가했고, 평가에 대한 신뢰성은 크론바흐 알파 값을 제시하였다. 결과적으로 처음 검사(대조군)에서 양측 위관절융기의 겹침과 팔꿉관절의 분리가 적절하지 않은 환자들은 아래팔뼈와 테이블 사이에 10° 각도를 설정하였을 때 가장 좋은 영상을 획득할 수 있었다. 이에 대한 정성적 평가 점수는 0°에서 1.6±0.8점, 5°에서 2.7 ± 0.8점, 10°에서 4.4 ± 1.3점이었고, 0°, 5°, 10° 각도에 대한 신뢰도 분석 결과 크론바흐 알파 값은 각각 0.867, 0.697 및 0.922였다. 결론적으로 기존의 검사 자세와 X선 입사 방식을 사용하여 정확한 영상을 얻을 수 없는 경우에는 아래팔과 테이블 사이의 각도를 10°로 설정한 후 우선적으로 영상을 획득하고 차츰 각도를 줄여가면서 영상을 획득한다면 반복 검사의 횟수를 줄이면서 최적의 영상을 얻을 수 있을 것으로 판단된다.

두개골 또는 뇌로 전이된 갑상선암 - 7례 분석 - (Skull or Brain Metastasis from Thyroid Carcinoma - Analysis of 7 Cases -)

  • 김석철;정신;김재성;이정길;김태선;김재휴;김수한;강삼석;이제혁;박재우;이민철
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권1호
    • /
    • pp.89-94
    • /
    • 2001
  • Skull or brain metastasis from thyroid carcinoma is rare. Between Jan. 1993. and Jan. 2000. the authors experienced 7 cases of skull(4 cases) or brain(3 cases) metastasis from thyroid carcinoma. Clinical characteristics, radiologic findings and pathologic features were analyzed retrospectively. Among 4 cases of skull metastasis, 3 cases were follicular carcinoma and one was papillary carcinoma with follicular variant. All cases of brain metastasis were papillary carcinoma. We treated the patients by combination with surgical resection, radioactive iodine therapy and radiation therapy. Characteristics of skull or brain metastasis from thyroid carcinoma is reviewed with a pertinent literature.

  • PDF

방사선안전관리에 대한 지식, 태도 및 행위의 추이분석 : 의료기관 방사선종사자를 중심으로 (Analysis of the Trend of Knowledge, Attitude and Behavior Related to Radiation Safety Management : Focused on Radiation Workers at Medical Institutions)

  • 한은옥;권덕문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.321-327
    • /
    • 2007
  • 본 연구는 방사선 종사자에 의해 주도되는 의료기관 방사선안전관리에 대해 교육학적 접근인 지식, 태도 및 행위를 조사하여 과거와의 연속선상에서 자료를 구축함으로써 시대적인 변화를 파악하고 보다 장기적이고 체계적인 추이분석을 함으로써 방사선 종사자뿐만 아니라 일반 이용자의 방사선에 의한 건강장해를 예방하기 위한 방사선안전관리 계획 수립에 필요한 근거자료를 도출하고자 시도하였다. 전국 의료기관 방사선종사자를 대상으로 2001년과 2006년도에 각각 약 40일 가량 설문조사를 실시하여 다음과 같은 결과를 도출하였다. 1. 방사선안전관리에 대한 지식, 태도 및 행위수준이 2001년보다 2006년도가 모두 높게 나타났다. 2. 방사선안전관리에 대한 지식, 태도 및 행위의 상관관계는 2001년, 2006년도 모두 지식과 태도, 행위와 지식, 태도와 행위에 대해 통계적으로 유의한 상관관계를 나타냈다. 특히 태도와 행위의 상관관계는 2006년도가 2001년보다 더 높은 상관관계를 나타냈다. 3. 방사선안전관리 행위에 영향을 미치는 요인으로는 2001년, 2006년도 모두 방사선안전관리에 대한 지식, 태도로 나타났고 지식보다 태도가 높은 것으로 나타났다.

  • PDF

초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구 (Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography)

  • 이종석;유병규;권대철
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.149-160
    • /
    • 2007
  • 초급성 허혈성 뇌졸중 환자를 대상으로 관류 전산화단층촬영(CT)의 임상적 적용을 평가하였다. 뇌졸중 증상 발현 62명의 환자를 대상으로 하였고, 관류 CT는 소뇌 기저부위에서 8 cm 상방으로 스캔하여 후처리 과정을 거쳐 뇌혈용적(cerebral blood volume, CBV), 뇌혈류량(cerebral blood flow, CBF), 평균 조영제 통과시간(mean transit time, MTT) 및 조영제 최고 도달시간(time to peak, TTP) 등의 네 가지 지도의 영상을 얻었다. 관류 CT의 CBV, CBF, MTT, TTP 지도에서 병변을 평가하였으며, 병변 부위와 정상측 대칭부위에서 MTT와 TTP를 측정하여 차이를 비교하였다. 관류 CT의 네 가지 지도 모두에서 관류결손을 인지할 수 있었고, 관류 결손이 인지되는 부위에서 MTT와 TTP의 현저한 지연이 있었다. 관류 CT의 MTT와 TTP영상이 초급성 허혈성 경계부위의 페넘브라를 반영하였다. 관류 CT의 네 가지 지도를 이용하면 뇌졸중의 조기 진단, 허혈 중심부, 허혈 페넘브라를 알 수 있게 되어 관류결손 부위의 혈류역동학적 평가가 가능함으로써, 허혈성 뇌졸중 환자의 진단 및 효과적인 치료를 위해 관류 CT가 유용하여 임상적 적용이 가능하다.

  • PDF

X-선 회절을 이용한 기체 저장제의 연구 (A Study on Gas Storage Medium by Using X-ray Diffraction)

  • 박종삼;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.147-155
    • /
    • 2006
  • 기체 저장제로서 제올라이트의 구조와 기체분자의 유출입 기전을 이해하기 위해 완전히 탈수된 $K_3-A$들을 제조하고 $K_3Na_8H-A(R_1=0.0478,\;R_2=0.0458$$a=12.257(1){\AA}$)의 결정구조들을 Pm3m 입방 공간군에서 단결정 X-ray 회절 방법으로 연구하였다. 진공 탈수된 $K_3Na_8H-A$의 결정구조에 있어서, 단위세포 당 3개의 $K^+$ 이온들이 8-ring(0.0, 0.4531, 0.4531) 상에 존재하였고, 단위세포 당 8개의 $Na^+$ 이온들이 6-oxygen ring들의 중앙에 위치하였다. 8-ring상에 존재하는 각 $K^+$ 이온들은 두 가지 종류의 골격산소 원자들로 부터 각각 $2.87(2){\AA}$$2.79(1){\AA}$의 거리를 가지고 있었다. 이러한 값들은 이미 기존에 알려진 $K_{12}Na-A$의 값들보다 더 짧은 값으로 이들의 이온 반경들을 고려할 때 더 타당한 값들이였다. $K^+$ 이온들의 정확한 위치들은 8-ring들의 중앙으로부터 약 $0.8{\AA}$ 떨어져 있었다. 이러한 결과는 제올라이트 골격을 안전화시켜 기체분자들의 효과적인 유출입 통제와 저장을 가능하게 하며, 유효 부피 극대화를 이루어 더 많은 기체 저장을 할 수 있으므로 병원에서 사용하는 산소 저장 용기를 더욱더 소형임은 물론 산소가 필요한 응급환자 들을 위한 휴대하기 간편한 용기를 만들어 줄 것으로 예상된다.

  • PDF

한 대학병원 종합건강진단센터에서 시행한 복부 초음파검사의 유소견 연구 (A Study on Abdomen Ultrasonography Classified by Particular Disease Practiced in Health Promotion Center of a University Hospital)

  • 김남희;최종학
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.33-41
    • /
    • 2001
  • This study is to get preliminary data for an effectiveness evaluation of abdominal examination and improvement of it. Abnormal cases of abdominal ultrasonography are classified by sex, frequency, diagnosis and age. 4,924 examinees were included at a university hospital of health promotion center from January to December in 1999. The results are as follows. 1. According to the distribution of sex, there are more male patients(55.0%) than females patients(48.0%). For men, 40's showed the highest percentage among examinees. For women, 50's were the highest. 2. The reason that they visited the health promotion center was that 'they wanted to check their health status'. This answers were reported the highest(59.3%). 3. Patients that had abnormal cases of abdominal ultrasonography were 48.3%. Liver, kidney, gallbladder showed the highest percentage of abnormal cases in order of organs. Additionally, abnormal cases were discovered in liver cases. 4. According to the frequency of abnormal cases among examinees, the slight fatty liver were the highest regardless of sex. Men had the slight fatty liver, kidney simple cyst, liver calcification and liver simple cyst in order of abnormal cases. Women showed the slight fatty liver kidney simple cyst, kidney calcification, liver simple cyst, and blood vessel tumor in order of abnormal cases. 5. For the abnormal cases of liver by sex and age, the 50's reported the highest number of abnormal cases in men(299 patients). In addition, 60's had the highest of disease rata 47.8%. For women, 50's reported the highest number of abnormal cases(361 patients). Over 70's patients had the highest of disease rata 52.6%. For kidney, men and women showed the highest number of abnormal cases -62 vs 44 respectively. Over 70's patients had the highest percentage of disease rata-23.2% vs 14.0% respectively. For gallbladder, the number of abnormal cases were the most in men's 60's (31 patients) and in women's in the same age group (32patients). Disease showed the highest percentage in men's 60's(7.6%) and in women's 70's (14.0%). 6. According to malignant tumor, 17patients were liver cancer, 2patients stomach ca and 1pt kidney cancer. 7. The relationship between the malignant tumor and the examination motive was that 'they wanted to check their health status(41.0%)' and 'regular checkup (24.0%)'.

  • PDF