• Title/Summary/Keyword: Radioisotope (RI)

Search Result 294, Processing Time 0.019 seconds

Development & Assessment of Alkyl Chain Modified Aptamers as Potential PET Radiotracers for Lymphoma Diagnosis

  • Ji Woong Lee;Un Chol Shin;Seok u Bae;Ji Yoon Kim;Hae joon Cho;Ji Ae Park;Kyo Chul Lee;Jung Young Kim;Suhng Wook Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • The Td05 and Sgc8c, DNA-based aptamers, are well-known to target internalized surface markers (IGHM and PTK7) of Burkitt's lymphoma and acute lymphoblastic leukemia (ALL). Thus, Td05 and Sgc8c labeled with metallic radioisotope 64Cu can be evaluated as potential diagnostic PET imaging agents. In this study, we modified the carbon chain length of the last adenosine of aptamer (n = 3, 6, 12) to increase tumor cell uptake and select the best candidate among six types of aptamer analogues and one adenosine of aptamer. After labeling of 64Cu, [64Cu]Cu-DOTA-aptamer analogues were evaluated in vitro studies (serum stability, Log P values, cell uptake, biodistribution). Then, we evaluate in vivo PET imaging study for two candidates (64Cu-DOTA-C12-Sgc8c, 64Cu-DOTA-C6-Td05). PET images clearly visualize tumors at 24 h post-injection rather than at an early time point and the tumor-to-background ratio also increases at the delay time point. 64Cu-DOTA-C12-Sgc8c and 64Cu-DOTA-C6-Td05 could be used as potential radiotracers for lymphoma.

Radiolabeled Benzamide Derivatives for Development of Malignant Melanoma Imaging Agents

  • Ayoung Pyo;Boreum Song;Heejung Kim;Dong-Yeon Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • Malignant melanoma has an aggressive nature and high metastatic potential that result in one of the highest cancer mortality rates. Over the past three decades, primary and metastatic melanoma incidence has rapidly increased. The recent advances in diagnostic technology have shown promise, but there is still an enormous need for specific detection methods to diagnose malignant melanoma. Positron emission tomography can visualize a particular biomarker of malignant melanoma and promise a noninvasive image of micrometastases. However, the development of PET radiopharmaceuticals remains necessary for diagnosing malignant melanoma by using positron emission tomography. In this review, the history and a general overview of PET radionuclide labeled benzamide derivatives, including their radiosynthesis, in vivo characterization, and evaluation, are provided as imaging agents for malignant melanoma.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

40Ar-39Ar Age Determination for the Quaternary Basaltic Rocks in Jeongok Area (전곡 지역 제4기 현무암질 암석의 40Ar-39Ar 연대 측정)

  • Kim, Jeongmin;Choi, Jeong-Heon;Jeon, Su In;Park, Ul Jae;Nam, Seong Soo
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.385-391
    • /
    • 2014
  • Quaternary basaltic rocks occur as volcanic plateau and/or river cliff in the watershed area of Hantan River in Jeongok, central Korea. We measured $^{40}Ar-^{39}Ar$ ages for the basaltic rocks from Jeongok area using the multi-collector noble gas mass spectrometer and laser heating device introduced for the first time in Korea. The basaltic rocks from the river cliff in Eundae-ri area show the systematic change in $^{40}Ar-^{39}Ar$ ages from $0.54{\pm}0.07Ma$ through $0.48{\pm}0.01Ma$ to $0.12{\pm}0.01Ma$ toward the top. The other sample from Jeongok-ri area yields the age of $0.43{\pm}0.04Ma$. This results suggest that there might be a episodic volcanic eruption between 0.12-0.54 Ma in Jeongok area.

Measuring Circuit Design of RI-Gauge for Compaction Control (성토시공관리용 방사성 동위원소 이용계기의 측정회로설계)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Ki-Joon;Whang, Joo-Ho;Song, Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.385-391
    • /
    • 1997
  • An objection of this study is to develop a measuring circuit of a gauge using radioisotope for compaction control. The gauge developed in this study makes use of radioisotope with the activity exempted from domestic atomic law and consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, and a microprocessor. To obtain meaningful numbers of pulse counts, parallel five and two circuits are provided for gamma-rays and thermal neutrons, respectively. Being simple in electrical characteristics of G-M detector for gamma-rays, pulses are counted through only a shaping circuit. Very small pulses generated from He- 3 proportional detector for thermal neutrons are amplified to the maximum of 50 [dB] and a window comparator accepts only pulses with meaning. To minimize effects of natural environmental radiation and electrical noise, circuits are electrostatically shielded and pulses made by ripples are eliminated by taking frequency of high voltage supplied to the circuit and pulse height of ripples into consideration. One-chip microprocessor is applied to process various counts, results are stored and the gauage is made capable to communicate with PC. Enough and meaningful numbers of pulses are counted with the prototype gauage for compaction control.

  • PDF

Detection of Alpha Tracks of Boron by Nuclear Reaction with Neutron (중성자 핵반응에 의한 보론의 알파트랙 검출)

  • Sohn, Se Chul;Pyo, Hyung Yeal;Park, Yong Jun;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • The detection efficiencies of the several solid track detectors were investigated for the determination of boron content in aqueous solution by using the alpha muti-Radioisotope(RI) source. Polycarbonate (Lexan and CR-39) and cellulose nitrate (CN-85 and LR-115) were selected as materials for alpha track detection of boron. Alpha muti-RI source, uranium metal particles and boron standard solution were used for alpha emission. In this study, four solid track detectors(CN-85, LR-115, Lexan and CR-39) were characterized under various etching conditions as well as neutron irradiation conditions. As a result, the CN-85 was turned out to be best to provide good efficiency among the four detectors. The selected solid track detector was utilized for the determination of trace amount of boron in aqueous sample and its results were discussed in the text.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

Analysis of Methodology for Designing Education and Training Model for Professional Development in the field of Radiation Technology (방사선 기술 분야 재직자 인력양성을 위한 직무분석에 기반한 교육 모델 설계 방법론 분석)

  • Kim, Kon-Wuk;Lee, Jae-Hun;Park, Tai-Jin;Song, Myung-jae
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The domestic Radiation Technology is integrated into and utilized in various areas and is closely related to the industrial growth in Korea. The domestic use of radiation and RI (Radioisotope) increases in quantity every year, however the level of technology is poor when compared to other developed countries. Manpower training is essential for the development of Radiation Technology. Therefore, this study aimed to propose a methodology for designing systemic education and training model in the field of measurement and analysis of radiation. A survey was conducted to design education and training model and the training program for measurement and analysis of radiation was developed based on the survey results. The education and training program designed in this study will be utilized as a model for evaluating the professional development and effective recruitment of the professional workforce, and can be further applied to other radiation-related fields.

Cu-64 as a Cancer Theranostics Agent

  • Kwang Il Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.139-150
    • /
    • 2022
  • Theranostics, a composite word of therapy and diagnosis, is known as personalized medicine and the concept of diagnosis and treatment at the same time. In nuclear medicine, it means performing both therapeutic and diagnostic radioisotope therapy using the same target molecule. The increased production and utilization of 64Cu opens a new era of theranostics. The studies introduced here have shown that 64CuCl2 and various compounds or biomolecules labeled with 64Cu are unique radiopharmaceuticals with physiological properties suitable for use as diagnostic and therapeutic agents. So far, these two abilities have been described only for radioactive iodine. Although 64Cu has complex chemical properties compared to other PET radioisotopes such as 68Ga, it has an appropriate half-life and enables high-quality PET images similar to 18F, which is an advantage in terms of diagnosis. In addition, since it also has therapeutic properties through the release of β- particles and Auger electrons by electron capture, radiopharmaceuticals using 64Cu stand for innovative radiopharmaceuticals for theranostic purposes. Therefore, based on the initial results obtained using 64Cu as a therapeutic agent, it is expected that additional research on the application of 64Cu will lead to a new era in the theranostics field.

Study of Classification and Disposal Method for Disused Sealed Radioactive Source in Korea (국내 폐밀봉선원 분류체계 및 처분방식 연구)

  • Kim, Sukhoon;Kim, Juyoul;Lee, Seunghee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.253-266
    • /
    • 2016
  • In accordance with the classification system of radioactive waste in Korea, all the disused sealed radioactive sources (DSRSs) fall under the category of EW, VLLW or LILW, and should be managed in compliance with the restrictions for the disposal method. In this study, the management and disposal method are drawn in consideration of half-life of radionuclides contained in the source and A/D value (i.e. the activity A of the source dividing by the D value for the relevant radionuclide, which is used to provide an initial ranking of relative risk for sources) in addition to the domestic classification scheme and disposal method, based on the characteristic analysis and review results of the management practices in IAEA and foreign countries. For all the DSRSs that are being stored (as of March 2015) in the centralized temporary disposal facility for radioisotope wastes, applicability of the derivation result is confirmed through performing the characteristic analysis and case studies for assessing quantity and volume of DSRSs to be managed by each method. However, the methodology derived from this study is not applicable to the following sources; i) DSRSs without information on the radioactivity, ii) DSRSs that are not possible to calculate the specific activity and/or the source-specific A/D value. Accordingly, it is essential to identify the inherent characteristics for each of DSRSs prior to implementation of this management and disposal method.