• Title/Summary/Keyword: Radioimmunoguided surgery

Search Result 3, Processing Time 0.019 seconds

Radioimmunoscintigraphy Using $^{99m}Tc-anti-CEA\;F(ab')_2$ Fragment in Rectal Cancer and a Pilot Study for Radioimmunoguided Surgery (직장암에서 $^{99m}Tc$-항CEA 항체 $F(ab')_2$ 분절을 이용한 수술 전 방사면역신티그라피 및 방사면역지침수술에 관한 기초 연구)

  • Ryu, Jin-Sook;Kim, Jin-Choen;Kim, Chang-Nam;Gong, Gyung-Yub;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.243-251
    • /
    • 2000
  • Purpose: This prospective study was performed to evaluate the usefulness of preoperative radioimmunoscintigraphy and intraoperative scintimetric examination (radioimmunoguided surgery: RIGS) using $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment. Materials and Methods: Nineteen patients with rectal cancer underwent preoperative whole body planar scintigraphy at 4 hours after injection of $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment and SPECT imaging at 18 hours. Surgical operation was performed at 24 hours after injection. During laparotomy, radioactivities from intraabdominal viscera were measured by gamma probe. The radioactivities from excised tumor and lymph nodes were also measured and compared with pathology. Results: All nineteen patients were confirmed to have adenocarcinomas in the rectum. Twenty-seven of 97 excised lymph node groups had metastasis and 2 patients had liver metastasis in pathology Preoperative radioimmunoscintigraphy detected primary tumors in 11 patients (sensitivity 55%) and it could not detect any lymph nodes or liver metastasis. All patients showed high radioactivity in the kidneys, liver, spleen, and major vessels in intraoperative measurement by gamma probe, and tumor activity was not discriminated from background activity However, radioactivity from excised tumor was higher than normal rectum (T/B ratio; $3.47{\pm}2.25$). When excised lymph node activity/background activity ratio >1.5 was considered as positive criteria of metastasis, sensitivity, specificity, positive and negative predictive values were 78.6%, 73.9%, 55.0% and 89.5%, respectively. Conclusion: Radioimmunoscintigraphy using $^{99m}Tc-anti-CEA\;F(ab')_2$ has no additional value for preoperative staging and use of early RIGS using $^{99m}Tc-anti-CEA\;F(ab')_2$ is inappropriate. For early RIGS using $^{99m}Tc$ labeled antibodies in rectal cancer patients, further development of more specific antibodies and methods to reduce background activity are needed.

  • PDF

Development of Portable Gamma Probe and Its Basic Performance Test (이동형 감마프로브 개발과 기본성능 평가)

  • Kim, H.J.;Kwark, C.;Choi, Y.;Yang, M.K.;Bong, J.K.;Lee, S.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.216-219
    • /
    • 1997
  • We are developing a portable multipurpose gamma counting and imaging probe that will be useful for many applications in nuclear medicine including radioimmunoguided surgery in the detection and treatment of malignant tumors. Any diagnostic information provided by CT, MRI, PET, SPECT or gamma camera imaging prior to surgery obviously is very important, but current techniques are limited in many instances. To overcome some of these limitations, the portable multipurpose gamma probe is being developed. The gamma probe consists of NaI(Tl) crystal with 1" dia $\times$ 0.5" thick and singlechannel photomultiplier tube (SC-PMT) for counting, and 3" dia $\times$ 0.375" and multichannel photomultiplier tube (MC-PMT) for imaging, nuclear instrument module (NIM), position circuits, interface, and PC. The energy resolution using Tc-99m was measured as 14% and the spatial resolution using 3mm dia green LED was measured as 2.9mm. These priliminary results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine.

  • PDF

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.