• Title/Summary/Keyword: Radiographic method

Search Result 373, Processing Time 0.025 seconds

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

Guided endodontics: a case report of maxillary lateral incisors with multiple dens invaginatus

  • Ali, Afzal;Arslan, Hakan
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.38.1-38.8
    • /
    • 2019
  • Navigation of the main root canal and dealing with a dens invaginatus (DI) is a challenging task in clinical practice. Recently, the guided endodontics technique has become an alternative method for accessing root canals, surgical cavities, and calcified root canals without causing iatrogenic damage to tissue. In this case report, the use of the guided endodontics technique for two maxillary lateral incisors with multiple DIs is described. A 16-year-old female patient was referred with the chief complaint of pain and discoloured upper front teeth. Based on clinical and radiographic findings, a diagnosis of pulp necrosis and chronic periapical abscess associated with double DI (Oehler's type II) was established for the upper left lateral maxillary incisor (tooth #22). Root canal treatment and the sealing of double DI with mineral trioxide aggregate was planned for tooth #22. For tooth #12 (Oehler's type II), preventive sealing of the DI was planned. Minimally invasive access to the double DI and the main root canal of tooth #22, and to the DI of tooth #12, was achieved using the guided endodontics technique. This technique can be a valuable tool because it reduces chair-time and, more importantly, the risk of iatrogenic damage to the tooth structure.

EARLY CARIES DETECTION WITH DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION (Digital Imaging Fiber-Optic Trans-Illumination을 이용한 초기우식의 탐지)

  • Lee, Jun-Seok;Kim, Jong-Soo;Yoo, Seung-Hoon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.3 no.2
    • /
    • pp.87-90
    • /
    • 2007
  • It's important that detect early caries of deciduous and permanent teeth to prevent dental caries and prevserve teeth, especially on proximal surface of deciduous teeth. The reason is that their prominent pulp horn lead to pulp treatment easily due to rapid caries progression. There are conventional exploring, visual inspection and radiographic exam for early caries detection. But, the standard method for diagnosing dental caries is subject and cavitation may be accelerated during exploring procedure. Caries can be diagnosed up to 40% mineral loss with radiograph. $DIFOTI^{(R)}$ (Digital Imaging Fiber-Optic TransIllumination) is diagnostic imaging system for early caries detection using fiber-optic illumination. It is possible that remineralize the tooth surface without tooth preparation and conserve the tooth structure by using $DIFOTI^{(R)}$.

  • PDF

COMPARATIVE STUDY OF POSTOPERATIVE SKELETAL SYMMETRY RELATED TO SURGICAL METHODS IN UNILATERAL CONDYLAR HYPERPLASIA (CONDYLECTOMY VS RAMUS SURGERY) (편측성 하악과두증식증에서 수술방법에 의한 술후 골격구조의 대칭성에 관한 비교연구)

  • Lee, Jeong-Gu;Hong, Kwang-Jin;Min, Byeong-Jin;Lee, Won-Hak;Cho, Yoon-Joo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.2
    • /
    • pp.200-207
    • /
    • 1996
  • In patients with unilateral condylar hyperplasia, increased length of the condylar neck causes deviation of the mandible to the opposite site, resulting in facial asymmetry, but the arch form and general contour of the displaced mandible is approximately symmetric. So, the unilateral condylectomy have been prefered surgical method among the surgeons. The purpose of this study is to analyze the postoperative results comparatively following two different surgical methods, condylectomy and ramus surgery, in unilateral condylar hyperplasia. Case of 6 patients with the unilateral condylar hyerplasia were analyzed in this study, 3 case of the condylectomy only, 3 cases of the ramus surgery, Clinical and radiographic evaluations were tried for comparison. In conclusion, comparative results between two groups did not show any significant difference, but we confirmed that unilateral condylectomy could be a excellent surgical methods in unilateral condylar hyperplasia thinking over the unique morphological characteristics of it.

  • PDF

Measurement of the Angle related Hallux Valgus in Normal Korean Adults (무지외반증에서 한국인의 정상 방사선각도 계측치에 대한 연구)

  • Lee, Kyung-Tai;Song, Joon-Sub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.11-14
    • /
    • 1997
  • Hallux valgus is a complex deformity which contains static subluxation of the first metatarsophalangeal joint with lateral deviation of the great toe and medial deviation of the first metatarsal bone. Among the several parameters, radiographic indices are the important ones in the choice of the treatment method. Even though, the normal values of the western peoples are already estabilished, there was no standard values for Korean who has different genetics, and cultural background, till now. So, we tried to estimate the noraml values of the HVA (hallux valgus angle ), IMA ( Intermetatarsal angle) and DMAA (Distal Metatarsal Articular surface Angle) in a normal adult. Fifty normal adult (each 25 male and female) were chosen and took 100 cases of foot radiograph and radiologic indices of the hallux valgus were measured. Average age at the investigation was 34.5 years old. The average HVA is $13.3^{\circ}$, IMA is $8.5^{\circ}$ and DMAA is $34.6^{\circ}$.

  • PDF

A RADIOGRAPHIC STUDY ON CRANIOFACIAL ASYMMETRY BY POSTERO-ANTERIOR CEPHALOMETRY (Postero-Anterior Cephalometry를 이용한 안모의 비대칭에 관한 연구)

  • Ko Jae Kyeung;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.249-258
    • /
    • 1987
  • The purpose of this article was to determine the amount of cranio-facial asymmetry in normal subject before the analysis of the cranio-facial asymmetry as the result of internal derangement in T.M.J. dysfunction. The author has conducted analysis using Cephalometric P-A reviews of 54 males and 51 females. Following the Grayson's method of measurement, the standard value of cranio-facial asymmetry in normal subject was obtained. The following results were obtained: 1. Compared with right and left width, asymmetry could be identified in normal subject, although the degree of the difference appears to be small. 2. In male, asymmetric value of contact point of the upper central incisors is 0.76±0.84㎜ that of the lower central incisors is 0.86±0.86㎜, and that of center of genial tubercle is 0.87±1.06㎜. In female, asymmetric value of contact point of the upper central incisors is 1.03±1.29㎜, that of lower incisors is 1.11 ±1.18㎜, and that of center of genial tubercle is 1.45±2.15㎜. 3. Cranio-facial saymmetry in female is somewhat greater than that of male.

  • PDF

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

A Survey on Medical Radiation Dose by the Radiographic Conditions of Chest (흉부 X선촬영 조건에 따르는 의료피폭에 관한 조사연구)

  • Huh, Joon;Kim, Sun-Soo;Park, Jun-Chul
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.79-87
    • /
    • 1992
  • It is a matter of common knowledge that madical radiation is most accented for of radiation is doses applied to the whole of people, and of them the radation dose by radiography diagnosis is mainly prevalent. In applying X-rays to a certain man for radiography diagnosis a radiologyist will have to have an absolute sense of mission concerning the reduction and prevention of the patient's radiation dose as the radiologyist obligation. Accordingly, the radiography conditions of the patient's chest employed 197 medical facilites were surveyed and skin dose was computated by the IPH Bit system and examined. As a result, it was shown that the average skin dose was $288\;{\mu}Sv$, its minimum value was $1600\;{\mu}Sv$, which was over 32 times its minimum value. This shows that the appropriate radiography method has not been applied at applying X-ray to the patient. It comes from the performance of X-ray equipment, the choice of auxiliary equipment materials etc. But the most important thing is to master the appropriate radiography condition, and therefore this point will have to be kept in mind.

  • PDF

Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction (전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Lee, Joong Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

CLINICAL STUDY OF ARTHROCENTESIS-CASES OF CLOSED LOCK (CLOSED LOCK증례에 대한 악관절 세정술의 임상적 연구)

  • Hyun, Young-Ok;Kang, Chang-Hee;Noh, Yang-Ho;Chun, Young-Doo;Lee, Hee-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2001
  • Purpose : To evaluate the efficacy of arthrocentesis for treatment of closed lock. Material : 42 patients were diagnosed to closed lock by physical, radiographic examriation and undergone arthrocentesis. All patients have a pain and mouth opening limitation on affected site. Method : Arthrocentesis was done under conscious sedation and local infiltration anesthesia, normal saline and some steroid was injected on upper compartment of tempormandibular joint. After pumping and lavage, manual reduction procedure of anterially displaced disc was done. All the patients wear an anterior repositioning splint just after arthrocentesis. The result of arthrocentesis was assessed by pain and difference of mouth opening. Result : Difference of mouth opening after arthrocentesis was improved to 18.85mm and pain was gradually decreased. All patients were worn stabilization type splint after mean 1.84 months. 6 patients had relapse of mouth opening limitation so done arthrocentesis again and delivered good results.

  • PDF