• 제목/요약/키워드: Radiographic film

검색결과 122건 처리시간 0.032초

Minocycline 국소 약물 방출 제제의 치주질환 치료 효과 (Effects of locally-delivered minocycline hcl on controlled periodontal disease)

  • 정미현;권영혁;허익;이만섭;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제28권1호
    • /
    • pp.37-56
    • /
    • 1998
  • The purpose of this study was to evaluate the clinical and microbiological outcomes following the use of 30% minocycline-loaded polycaprolacton film and 2% minocycline-loaded gel that was applied locally into pockets combined with scaling and root planing. 25 human subjects who were non-pregnant, non-lactating, aged 20-50 and diagnosed as moderate to advanced adult periodontitis were enrolled. Subjects were excluded if they had a history of severe acute or chronic systemic disease, if they required antibiotic prophylaxis for dental treatment for any reason, or if they reported a history suggestive of hypersensitivity reactions to minocycline or tetracycline. 4quadrants that had several teeth with a 5-8mm probing pocket depth and radiographic evidence of alveolar bone loss for each patient were selected and divided into test sites and control sites according to the split-mouth design. Scaling and root planing was done for each site at baseline(0week). Test sites received the minocycline gel and strip and control sites had saline irrigation. The patients received both treatments simyltaneously. Subgingival irrigation of sterile saline was applied to the control sites for approximately 30 seconds. Minocycline strip and gel was applied into the periodontal pocket at 1, 2, 3, 4 weeks each after scaling and root planing in the test sites. The clinical and microbiological measurements were made at baseline and at the follow-up visits 6, 10, 14, 20 weeks. The results of this study were as follows; 1. The sulcular bleeding index, probing pocket depth and Periocheck test was significantly reduced and the relative proportions of spirochetes and motile rods were significantly reduced and the proportion of cocci was correspondingly increased, in locally delivered minocycline strip group compared to saline irrigation group. 2. In locally delivered minocycline gel group, The effect was the same with minocycline strip group as compared with saline irrigation therapy. 3. There was no significant differences between minocycline strip group and minocycline gelgroup. In conclusion, minocycline HCl local drug delivery combined with scaling and root planing may provide added improvement of clinical and microbiological responses by inhibiting bacterial recolonization of treated sites. It is suggested that the local administration of minocycline-HCl in the periodontal pocket is effective when combined with subgingival mechanical debridement.

  • PDF

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.

단일 분절 퇴행성 경추질환에서 Titanium Cage를 이용한 전방 융합술의 조기 치험 : 골편 이식을 동반하지 않은 경우의 임상적 방사선학적 초기 결과 (Preliminary Experience with Cervical Implantable Titanium Cage(RABEA) in Patients with Monosegmental Degenerative Disease : Clinical and Radiological Outcomes without Cancellous Bone Filling into Cage)

  • 이영균;한영민;김종태;정동섭;박영섭;박춘근;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup2호
    • /
    • pp.300-308
    • /
    • 2001
  • Objectives : Anterior cervical discectomy and interbody fusion has become a well-accepted surgical treatment of degenerative cervical diseases. Implatable cages have a stabilizing effect without plates and no need for autogenous bone graft. The authors evaluates the effect of implatable titanium cage(RABEA) on the clinical and radiological outcomes. Methods : 34 patients with symptomatic cervical degenerative diseases due to one level disc pathology were underwent anterior cervical discectomy and interbody fusion with titanium cages(RABEA) which were not filled with cancallous bone grafts from January 1999 to May 2001. Patients with osteoporosis and older than 65 years were not included. Among them, 15 patients could be followed-up for at least 1 year. The authors retrospectively reviewed the charts and radiographic data. Mean follow-up period was $1.3{\pm}0.2years$. Results : Clinical results according to the Odom's criteria was exellent and good in 14(93%) patients. One patient with fair result showed complete loss of the disc space height due to settlement of the cage. Preoperatively, the mean height of the disc space(${\pm}$standard deviation) was $3.42{\pm}1.10mm$(range 2.0-5.5mm), and at 1 day postoperatively it was $7.88{\pm}0.90mm$(range 6.50-9.0). The mean height of the disc space after 1 year was $6.50{\pm}1.38mm$(range 3.0-8.0). The restoration of the height was statistically significant(p<0.05). The mean height after 1 year was $82.7{\pm}15.9%$ of the height at 1 day postoperatively. Preoperatively the mean value of the cervical lodortic angle was $21.8{\pm}11.8^{\circ}$ and 1 year postopertively, it was $24.5{\pm}8.3^{\circ}$, which was statistically not significant. All patients showed no abnormal movements on flexion and extension lateral film after 6 months. Conclusion : Implantable titanium cages appear safe and effective in selected patients, and their use helps to avoid complications associated with bone graft harvest. Subsidence of the cage seems to be a potential risk factor for recurrence of the symptoms. For long-term results, a longer follow-up is required.

  • PDF

복강경하(腹腔鏡下)에서의 Hysterosalpingogram (Combined Hysterosalpingography and Laparoscopy in Infertility)

  • 구병삼
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제7권1_2호
    • /
    • pp.11-20
    • /
    • 1980
  • Hysterosalpingograms (H.S.G.) have been done for several decades to determine causative factors in female infertility. However, the H.S.G. only reverals uterine cavity and tubal patency or inpatency. The author prefers to find more details in regard to the status and condition of the female reproductive organs and their surrounding tissue as they pertain to infertility. H.S.G. in combination with laparoscopic examination reveals the following results. Preparation and method of performance of H.S.G. during laparoscopy in a healthy reproductive age women are as follows. When laparoscopy is not contraindicated, NPO is ordered with routine bowel preparation. Analgesics administered by injection prior to procedure are valium 10mgs and pethidine 50-100mgs. The radiographic procedure is the same as for any HSG technique. During laparoscopy a solution of 3 to 10 ccs. of 60% hypaque sodium is used. Fluroscopic scout films are obtained A-P and oblique views as well as a delayed check film. 1. Age distribution of primary and secondary infertility in this studies involving tubal factors was as follows: 20-29 age group showed 46% incidence and in the 30-39 age group, 50% incidence. Duration of infertility in this study group was the following: 1-2 years showed 26.7%, 3-5 years 53.8%, and 6-9 years 13.3%. 2. Indications of laparoscopic examination were as follows: Secondary infertility in 35% of the cases, obscure tubal occlusion on previous H.S.G. in 25%, unknown origin in 11.7%, and the remaining cases included pelvic pain, small masses, dysmenorrhea, and uterine anomaly. The laparoscopic examination showed clearly the reproductive organs and the surrounding tissues in the pelvic cavity. The abnormal tubal findings there revealed were tuberculous salpingitis and hydrosalpinx in 10% each, endometriosis and peritubabl adhesions in 6.7% each, biconuate uterus in 3.3%. The remaining 58.3% of the cases showed normal findings. Laparoscopic observation for possible myoma nodules, streak ovary, and peritubal adhesions was also done at this time. 3. Comparative tubal findings in combined H.S.G. and laparoscopic examination revealed the following. Bilateral tubal occlusion was present in 14% (7cases) on laparoscopic examination but on H.S.G. 38% (19 cases) were noted. However, tubal occlusion and peritubal adhesions were found in 26% (13 cases) upon laparoscopy and only 8% (4 cases) on H.S.G. examination alone. Normal pelvic findings were present in 60% (27 cases).

  • PDF

방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석 (The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System)

  • 나병식;정웅기;안성자;남택근;윤미선;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.82-88
    • /
    • 2005
  • 상용화된 방사선 치료계획 장치에서 제공하는 선량보상체(compensator) 설계 기능의 타당성 을 검증하고자 Cerrobend 재료를 대상으로 한 고밀도의 선량보상체 설계 및 제작과 동적다엽콜리메이터를 활용한 전자 선량보상체(Electronic Compensator)의 구현을 통해 그 기능을 분석하였다. 5개의 두께가 다른 영역으로 구성한 팬텀을 대상으로 전산화단층촬영(CT) 영상을 획득하고, 기준 깊이에서 균일한 선량분포를 형성하도록 방사선치료계획장치(RTP)에서 선량보상체를 설계하였다. Cerrobend 선량보상체 주조 틀을 제작하기 위해 컴퓨터로 자동 제어되는 스티로폼 절삭기를 사용하였고, 전자선량보상체를 구현하기 위해 다엽콜리메이터를 사용하였으며, 선량분포의 측정을 위해서 선량측정용 필름을 사용하였다. 선량보상체를 적용하지 않았을 경우, 선량분포에서 $\pm13.93 cGy$의 편차를 보였으나, Cerrobend 선량보상체와 전자선량보상체를 적용하였을 경우, 각각 $\pm0.99 cGy$$\pm1.82cGy$의 편차를 보여 선량분포의 균일도를 높이는 선량보상체로서 기능을 구현함을 증명하였다. 방사선치료계획장치에서 계획된 기준 선량값과의 평균 오차를 분석한 결과, Cerrobend 선량보상체는 $+3.83\%$, 전자 선량보상체는 $-4.37\%$의 오차를 보였으며, 이는 Cerrobend 선량보상체 제조과정에서의 오차와 절대 선량측정 도구로서 필름이 갖고 있는 한계성을 고려할 때, 선량보상체 기능의 정확도 입증에 타당성 있는 결과로 생각한다.

  • PDF

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF

CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화 (Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma)

  • 김혜원;김창근;윤권하;김현정;정선관;노병석;;;이현철
    • 대한핵의학회지
    • /
    • 제33권3호
    • /
    • pp.289-297
    • /
    • 1999
  • 목적: 저산소 세포에 결합하는 I-131-Iodomisonidazole (IMISO)을 이용하여 CT-26 선암을 접종한 마우스를 대상으로 생체분포와 신티그라피 및 자가방사영상을 얻어 저산소증 종양의 영상화가 가능한지 알아보고자 하였다. 대상 및 방법: Tosyl-misonidazole에 I-131-NaI를 첨가하여 IMISO를 방사합성하였고, CT-26 선암을 대퇴부 피하에 접종한 마우스에 IMISO를 주입 훈 1, 2, 4, 24시간에 각각 3마리씩 희생시켜 생체분포를 측정하였다. IMISO 주입 후 4시간에 신티그라피를 시행하고 동결미세절편기로 관상절편을 얻어 자가방사영상을 얻었다. T2강조 자기공명영상을 얻어 자가방사영상과 비교하였다. 결과: 종양섭취(%ID/g)는IMISO주사 후 1, 2, 4, 24시간에 각각 1.64, 0.98, 0.85, 0.20이었다. 종양섭취는 주사 후 24시간에 갑상선을 제외한 모든 장기보다 높았다. 종양/근육비는 주사 후 1, 2, 4, 24시간에 각각 2.08, 2.13, 2.68, 2.99로서 시간이 지남에 따라 증가하였고, 종양/혈액비도 주사 후 1, 2, 4, 24시간에 각각 0.57, 0.62, 0.76, 1.53 으로서 시간이 지남에 따라 증가하였다. 자가방사영상에서 종양의 중심부에 방사능이 축적되어 종양을 뚜렷이 관찰 할 수 있었고 이 부위는 T2강조 자기공명영상에서 고신호 강도로 관찰되었다. 주사 후 4시간에 얻은 신티그라피에서 종양섭취를 관찰 할 수 있었다. 결론: IMISO를 이용하여 마우스의 대퇴부 피하에 접종한 CT-26 선암의 종양저산소증을 영상화 할 수는 있었으나 보다 만족스런 영상을 얻기 위해서는 종양섭취를 향상시킬 수 있는 방법이 더 강구되어야 할 것으로 사료된다.

  • PDF

근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구 (A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS)

  • 김용상;김서경;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.107-114
    • /
    • 2008
  • 본 실험에서는 다양한 방사선 노출 조건에 따른 aluminum step wedge에 대한 광학 밀도를 알아보고, 그 중 적절한 노출조건을 선택하여 수종의 근관 충전재와 치근단 역충전재의 방사선 불투과성 정도를 평가, 비교하였다. 방사선 불투과성의 기준을 위해 11개의 step으로 구성된 aluminum step wedge를 제작하여, 60 kVp, 70 kVp 관전압 상태에서 각각 0.2, 0.,3, 0.4초와 0.2, 0.3, 0.33초의 노출시간으로 교합 필름상에서 방사선 촬영 후 적절한 노출조건을 구하였다. 직경 5 mm, 각각의 두께 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm인 10종 (Gutta-percha, amalgam, Super $EBA^{(R)}$, MTA, $IRM^{(R)}$, Fuji II LC, $Dyract^{(R)}$ AP AH, $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$)의 근관 충전재와 치근단 역충전재 시편을 각 재료와 두께당 10개씩 제작한 후, 동일한 두께의 상아질 시편, aluminum step wedge와 함께 정해진 노출조건에 따라 방사선 촬영을 하였다. 모든 필름은 자동현상기로 현상하였다. 시편의 흑화도를 densitometer (Model 07-443, Victoreen Inc, Cleveland, Ohio, USA)로 5회 반복 측정 후, 평균값을 구하여 회귀분석 후 알루미늄 두께로 환산하였다. 얻어진 정보를 분석하여 다음의 결과를 얻었다. 1. 관전압 60 kVp에서 노출시간 0.2, 0.3, 0.4초, 70 kVp에서 0.2, 0.3. 0.33초로 변화를 주어 방사선 촬영을 하였을 때, 흑화도가 0.5-2.5 사이여야 한다는 ISO No. 6876 규격에 가장 적합한 것은 60 kVp, 0.2초일 경우였다. 2. 측정된 근관 충전재와 치근단 역충전재들의 방사선 불투과성 모두 ISO No.4049 규격에 적합하였다. 3. 광중합형 글래스 아이오노머 (Fuji II LC)와 컴포머 (Dyract)를 제외하고는 ANSI/ADA specification (2000) 또는 ISO No. 6876 (2001)규격이 제시한 최소한 3 mm Al 이상의 방사선 불투과성을 지녀야 한다는 규격에 적합하였다. 이상의 결과는 본 실험에 사용된 수종의 근관 충전재와 치근단 역충전재 중 Fuji II LC와 Dyract를 제외하고 모두 규격에 적합한 방사선 불투과성을 가지고 있음을 시사한다.

정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출- (DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT-)

  • 이근호;이상한;장현중;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권3호
    • /
    • pp.214-220
    • /
    • 2001
  • 안면비대칭이나 반안면왜소증과 같은 구강악안면영역의 기형에 대한 진단 및 치료 계획 수립을 위하여 두개 악안면 구조물에 대한 총체적인 접근이 필요하다. 이에 두부 규격 방사선 사진을 이용한 3차원 두부 계측 방사선 시스템의 임상적 적용이 계속 시도되었으나 주로 두 방향의 방사선원으로부터 동시에 얻어진 standard Broadbent-Bolton cephalometer에 한정되어 있었다. 이에 본 연구에서는 단일방사선원에 의하여 촬영된 한 쌍의 정모 및 측모두부방사선 사진으로 정확한 3차원 좌표치를 얻을 수 있는 방법을 개발하고 이렇게 얻어진 3차원 좌표치의 정확도와 재현성을 검증하여 다음과 같은 결과를 얻었다. 1. 정모, 측모 두부 방사선 사진을 동시에 촬영하지 않음으로 인하여 생기는 오차를 보정해주는 수학적인 공식을 산출하고 이 공식에 의거하여 정모 두부 방사선 사진에 기준한 측모 두부 방사선 계측 사진의 위치 결정시의 오차를 건조 두개골을 이용하여 검증한 결과 1차와 2차 측정시 각각 평균 $0.46{\pm}1.21^{\circ}, $0.33{\pm}0.90^{\circ}로 나타났다. 2. 단일 방사선원으로부터 3차원 계측점의 좌표값을 얻을때의 재현성을 파악하기 위한 임상적 계측 결과 1, 2차측정간의 오차가 절대값 평균 0.54mm ($-2.99{\sim}2.26mm$)로 나타났으며 이때 계측점 인식의 오차는 평균 $1.2{\pm}1.6mm$ 였다. 위와 같은 결과를 종합하여 볼 때 정모 두부 방사선 사진에 의거한 측모 두부 방사선 계측사진의 위치를 결정한 후 두부위치 보정공식을 도입하면 임상적으로 충분히 재현성 있는 3차원 계측을 할 수 있다는 것을 알 수 있었다.을 증가시킨다. - PKC pathway는 MAPK pathway를 경유하여 Runx2의 전사 활성을 조절한다.있을 것으로 사료된다.대구치의 원심경사는 필연적으로 일어나며, 이를 최소화하기 위한 노력이 계속되어야 할 것으로 사료된다.글래스 아이오노머 시멘트 사이에는 유의한 차이가 없었다.착제의 종류에 따른 전단결합강도를 비교한 결과, 영구치와 유치 모두에서 Clearfil SE Bond를 사용한 군의 전단결합강도가 가장 높았으며 AQ Bond를 사용한 군의 전단결합강도가 가장 낮았다.본에서 III군에 비해 크기가 큰 기포가 더욱 많이 관찰되었다.e의 약동학은 cimetidine에 의해 유의한 차이를 보였으며 CYP1A2유전자형에 따른 영향은 관찰할 수 없었다. CYP1A2유전자형에 따른 생체내 대사능을 관찰하는 실험이 향후 이루어 져야 할 것으로 사료된다.san film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3주이상 경과후 적어도 4주째 수술시기를 정하는 것이 유리하리라 생각되었다.한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.또 다른 약물인 glycyrrhetinic acid($100{\mu}M$)도 CCh 자극으로 인한 타액분비를 억제하였다. 이상의 결과로 미루어

  • PDF

진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구 (A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;조평곤;이영배;김철민
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA는 영상의 질에 영향을 주지 않는 범위에서 피부흡수선량의 기준선량을 제시하였다. 이러한 개념은 점차적으로 국제적인 기준으로 사용하게 되었다. 이 기준선량은 강제사항이 아니며 권고사항이지만 방사선촬영에서 아주 훌륭한 기준이 된다. 그러나 IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리나라 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 방사선촬영 시 촬영부위에 따른 환자 피폭선량에 대한 기준을 따로 개발해야 할 필요가 있다. 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서 답한 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 방사선장치의 이용현황을 분석한 결과는 다음과 같다 1) 방사선장치의 현황은 일반촬영장치가 42.0%, 투시촬영장치가 29.4%, 치과장치가 13.2%, CT 장치가 8.1% 그리고 유방촬영장치가 7.2%로 나타났다. 2) 방사선장치의 정류방식에 따른 분류는 삼상장치가 29.9%, 인버터장치가 29.5%, 단상장치가 25.5%, 콘덴서방식이 9.0% 그리고 무응답이 6.0%였다. 3) 방사선장치의 수광방식에 따른 분류는 F/S 방식이 46.8%, CR 방식이 26.6%, DR 방식이 17.7% 그리고 무응답이 8.9%로 나타났다. 4) 방사선 촬영건수는 흉부가 49.2%, 척추가 16.8% 그리고 복부가 12.7%순으로 나타났다. 5) 환자 피폭선량은 두부 전후방향촬영 2.23 mGy, 복부 전후방향촬영 3.20 mGy 그리고 흉부 후전방향촬영 0.28 mGy로 나타났다.

  • PDF